Effect of O2, Ni0 coatings, and iron oxide phases on pentachlorophenol dechlorination by zero-valent iron

被引:5
作者
Gunawardana, Buddhika [1 ,2 ]
Swedlund, Peter J. [3 ]
Singhal, Naresh [2 ]
机构
[1] Univ Moratuwa, Dept Civil Engn, Moratuwa, Sri Lanka
[2] Univ Auckland, Dept Civil & Environm Engn, Auckland 92019, New Zealand
[3] Univ Auckland, Dept Chem, Auckland 92019, New Zealand
关键词
Bimetal; Dissolved oxygen; Iron oxides; Magnetite; Nickel; Passivation; ZVI; LONG-TERM PERFORMANCE; REDUCTIVE DECHLORINATION; CATALYTIC HYDRODECHLORINATION; CARBON-TETRACHLORIDE; FE/NI PARTICLES; KINETICS; FE; CHLOROPHENOLS; NANOPARTICLES; MECHANISM;
D O I
10.1007/s11356-019-06009-w
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study explores the zero-valent iron (ZVI) dechlorination of pentachlorophenol (PCP) and its dependence on the dissolved oxygen (O-2), presence/formation of iron oxides, and presence of nickel metal on the ZVI surface. Compared to the anoxic system, PCP dechlorination was slower in the presence of O-2, which is a potential competitive electron acceptor. Despite O-2 presence, Ni-0 deposited on the ZVI surfaces catalyzed the hydrogenation reactions and enhanced the PCP dechlorination by Ni-coated ZVI bimetal (Nic/Fe). The presence of O-2 led to the formation of passivating oxides (maghemite, hematite, lepidocrocite, ferrihydrite) on the ZVI and Nic/Fe bimetallic surfaces. These passive oxides resulted in greater PCP incorporation (sorption, co-precipitation, and/or physical entrapment with the oxides) and decreased PCP dechlorination in the oxic systems compared to the anoxic systems. As received ZVI comprised of a wustite film, and in the presence of O-2, only approximate to 17% PCP dechlorination observed after 25 days of exposure with tetrachlorophenol being detected as the end product. Wustite remained as the predominant oxide on as received ZVI during the 25 days of reaction with PCP under oxic and anoxic conditions. ZVI acid-pretreatment resulted in the replacement of wustite with magnetite and enhanced PCP degradation (e.g. approximate to 52% of the initial PCP dechlorinated after 25 days under oxic condition) with accumulation of mixtures of tetra-, tri-, and dichlorophenols. When the acid-washed ZVI was rinsed in NiSO4/H2SO4 solution, Ni-0 deposited on the ZVI surface and all the wustite were replaced with magnetite. After 25 days of exposure to the Nic/Fe, approximate to 78% and 97% PCP dechlorination occurred under oxic and anoxic conditions, respectively, producing predominantly phenol. Wustite and magnetite are respectively electrically insulating and conducting oxides and influenced the dechlorination and H-2 production. In conclusion, this study clearly demonstrates that the dissolved oxygen present in the aqueous solution decreases the PCP dechlorination and increases the PCP incorporation when using ZVI and Nic/Fe bimetallic systems. The findings provide novel insights towards deciphering and optimizing the performance of complex ZVI and bimetallic systems for PCP dechlorination in the presence of O-2.
引用
收藏
页码:27687 / 27698
页数:12
相关论文
共 54 条
  • [31] Complete dechlorination and mineralization of pentachlorophenol (PCP) in a hydrogen-based membrane biofilm reactor (MBfR)
    Long, Min
    Ilhan, Zehra Esra
    Xia, Siqing
    Zhou, Chen
    Rittmann, Bruce E.
    [J]. WATER RESEARCH, 2018, 144 : 134 - 144
  • [32] Roles of reactive oxygen species (ROS) in the photocatalytic degradation of Check pentachlorophenol and its main toxic intermediates by TiO2/UV
    Ma, Hai-Yan
    Zhao, Lixia
    Guo, Liang-Hong
    Zhang, Hui
    Chen, Feng-Jie
    Yu, Wan-Chao
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2019, 369 : 719 - 726
  • [33] REDUCTIVE DEHALOGENATION OF CHLORINATED METHANES BY IRON METAL
    MATHESON, LJ
    TRATNYEK, PG
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (12) : 2045 - 2053
  • [34] Dechlorination of chlorinated phenols by catalyzed and uncatalyzed Fe(0) and Mg(0) particles
    Morales, J
    Hutcheson, R
    Cheng, IF
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2002, 90 (01) : 97 - 108
  • [35] Wustite in a hydrothermal silver-lead-zinc vein, Lucky Friday mine, Coeur d'Alene mining district, USA
    Nadoll, Patrick
    Mauk, Jeffrey L.
    [J]. AMERICAN MINERALOGIST, 2011, 96 (2-3) : 261 - 267
  • [36] A critical review on the process of contaminant removal in Fe0-H2O systems
    Noubactep, C.
    [J]. ENVIRONMENTAL TECHNOLOGY, 2008, 29 (08) : 909 - 920
  • [37] Noubactep C, 2013, CLEAN-SOIL AIR WATER, V41, P1
  • [38] Mechanism of oxide film formation on iron in simulating groundwater solutions: Raman spectroscopic studies
    Odziemkowski, MS
    Schuhmacher, TT
    Gillham, RW
    Reardon, EJ
    [J]. CORROSION SCIENCE, 1998, 40 (2-3) : 371 - 389
  • [39] Magnetic, electronic, and structural characterization of nonstoichiometric iron oxides at the nanoscale
    Redl, FX
    Black, CT
    Papaefthymiou, GC
    Sandstrom, RL
    Yin, M
    Zeng, H
    Murray, CB
    O'Brien, SP
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (44) : 14583 - 14599
  • [40] An in situ study of the role of surface films on granular iron in the permeable iron wall technology
    Ritter, K
    Odziemkowski, MS
    Gillham, RW
    [J]. JOURNAL OF CONTAMINANT HYDROLOGY, 2002, 55 (1-2) : 87 - 111