Quadrant Detector-Based Method for Eyepoint Alignment of Augmented and Virtual Reality Head Mounted Displays

被引:3
作者
Bader, Ashraf M. [1 ]
Badano, Aldo [1 ]
Beams, Ryan [1 ]
机构
[1] US FDA, Off Sci & Engn Labs, CDRH, Silver Spring, MD 20993 USA
来源
OPTICAL ARCHITECTURES FOR DISPLAYS AND SENSING IN AUGMENTED, VIRTUAL, AND MIXED REALITY (AR, VR, MR) III, VOL. 11931 | 2022年 / 11931卷
关键词
Virtual Reality; Augmented Reality; Optical Characterization;
D O I
10.1117/12.2614415
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a quadrant detector-based method for aligning image sensors to the optical axis of augmented reality (AR) and virtual reality (VR) head mounted displays (HMDs). The sensor location that gives optimal image quality is known as the eyepoint. While a wide variety of methods have been explored for determining the eyepoint, the sensitivity and results of these methods depend on the optical design of the HMD. In our quadrant detector-based method, a test pattern consisting of dots is displayed on the HMD and imaged by a camera. The signal from the camera is divided into four quadrants and the camera is positioned at the eyepoint when the signal difference between the quadrants is minimized. This method has the advantage of giving the direction of the eyepoint from a single measurement without mapping the eyebox of the HMDs. The measurements were performed using an FDA developed setup for characterizing HMDs with the flexibility to incorporate a variety of light measuring devices and HMDs using commercially available components, which is described in detail. These results demonstrate a generalizable eyepoint alignment method, which allows for simpler automation of aligning the camera to the eyepoint.
引用
收藏
页数:7
相关论文
共 10 条
[1]  
[Anonymous], 2020, 6314520102019 IEC
[2]   Development of a Benchtop Photon Counting Cone-Beam CT System with a Translate-Rotate Geometry [J].
Bader, A. M. ;
Makeev, A. ;
Glick, S. J. ;
Ghammraoui, B. .
MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
[3]   Eyebox Centering Using Chromatic Aberrations of Virtual Reality Head-Mounted Displays [J].
Beams, Ryan ;
Kim, Andrea S. ;
Badano, Aldo .
OPTICAL ARCHITECTURES FOR DISPLAYS AND SENSING IN AUGMENTED, VIRTUAL, AND MIXED REALITY (AR, VR, MR), VOL. 11310, 2020, 11310
[4]  
Draper Russell S., 2018, SID Symposium Digest of Technical Papers, V49, P961, DOI 10.1002/sdtp.12209
[5]  
Gupta A., 2020, DIGITAL SURG, P233
[6]   Telemedicine and telementoring in the surgical specialties: A narrative review [J].
Huang, Eunice Y. ;
Knight, Samantha ;
Guetter, Camila Roginski ;
Davis, Catherine Hambleton ;
Moller, Mecker ;
Slama, Eliza ;
Crandall, Marie .
AMERICAN JOURNAL OF SURGERY, 2019, 218 (04) :760-766
[7]  
Li K., 2019, SID S DIGEST TECHNIC, V50, P434
[8]   THRESHOLD SELECTION METHOD FROM GRAY-LEVEL HISTOGRAMS [J].
OTSU, N .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1979, 9 (01) :62-66
[9]  
Smith W.J., 2008, MODERN OPTICAL ENG
[10]   Virtual reality for management of pain in hospitalized patients: A randomized comparative effectiveness trial [J].
Spiegel, Brennan ;
Fuller, Garth ;
Lopez, Mayra ;
Dupuy, Taylor ;
Noah, Benjamin ;
Howard, Amber ;
Albert, Michael ;
Tashjian, Vartan ;
Lam, Richard ;
Ahm, Joseph ;
Dailey, Francis ;
Rosen, Bradley T. ;
Vrahas, Mark ;
Little, Milton ;
Garlich, John ;
Dzubur, Eldin ;
IsHak, Waguih ;
Danovitch, Itai .
PLOS ONE, 2019, 14 (08)