Accuracy of marginal fit and axial wall contour for lithium disilicate crowns fabricated using three digital workflows

被引:28
|
作者
Sadid-Zadeh, Ramtin [1 ]
Katsavochristou, Anastasia [1 ]
Squires, Taylor [2 ]
Simon, Michael [2 ]
机构
[1] SUNY Buffalo, Sch Dent Med, Dept Restorat Dent, 215 Squire Hall, Buffalo, NY 14214 USA
[2] SUNY Buffalo, Sch Dent Med, Buffalo, NY USA
关键词
CHAIRSIDE CAD/CAM SYSTEMS; FILM THICKNESS; RESTORATIONS; IMPRESSIONS; SOLUBILITY; RETENTION; FITNESS; RESIN;
D O I
10.1016/j.prosdent.2018.11.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Comparative assessment of the effectiveness of computer-aided design and computer-aided manufacturing (CAD-CAM) technologies used to fabricate complete-coverage restorations is needed. A quantitative assessment requires precise documentation of the marginal adaptation and external surface contour of fabricated restorations. Limited information is currently available regarding the effects of milling mode on marginal adaptation and reproduction of the external surface contour for CAD-CAM-fabricated restorations. Purpose. The purpose of this in vitro study was to evaluate the outcomes for 3 different digital workflows on the marginal gap and the external surface contour reproducibility of CAD-CAM-fabricated lithium disilicate complete-coverage restorations. Material and methods. Twelve Ivorine molars were prepared to receive lithium disilicate crowns. The preparations were digitally recorded using 2 intraoral scanners (TRIOS 3; 3Shape A/S and Planmeca PlanScan; E4D Technologies), and the restorations were designed using their associated design software with reference to the anatomy of an unprepared tooth. The designed restorations were then manufactured from lithium disilicate blocks using a 3-axis milling machine. Twelve restorations were manufactured using the detailed mode (Planmeca PlanScan detailed mode [PPD-D]), and 12 using the standard mode for the Planmeca system (Planmeca PlanScan standard mode [PPD-S]). Restorations from the 3Shape system were fabricated using the detailed mode (TRIOS 3Shape detailed mode [T35-D]). The restorations were secured on their associated preparation with an elastomeric material. The marginal gap of each restoration was then measured in the lmageJ software using images captured by a stereo microscope at x20 magnification. External surface reproducibility was evaluated by measuring undercut at 4-line angles using a dental surveyor. Differences in the marginal gaps of restorations fabricated using the 3 different workflows were compared by Brown-Forsythe robust ANOVA, followed by a post hoc test (alpha=.05). Chi-square analysis (alpha=.05) was used to evaluate differences in the contours of the external surface of the restorations, resistance form, and marginal integrity produced using the 3 workflows. Results. The mean marginal gap for restorations fabricated using the T3S-D workflow was 60 mu m, a distance significantly lower (P<.05) than that of PPD-D and PPD-S workflows, which yielded a marginal gap of 95 mu m for the detailed mode and 124 lim for the standard mode of milling. Restorations fabricated using PPD-D and PPD-S workflows produced a significantly more reproducible external surface contour than those fabricated using the T3S-D workflow. Conclusions. Restorations fabricated using the T3S-D workflow produced the smallest marginal gap. However, reproducibility of the external surface contour for this workflow was the worst of the three workflows analyzed.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 45 条
  • [31] Vertical marginal fit of zirconia copings fabricated with one direct and three indirect digital scanning techniques
    Akhlaghian, Marzieh
    Khaledi, Amir-Alireza
    Farzin, Mitra
    Pardis, Soheil
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (03) : 421 - 426
  • [32] Randomized controlled within-subject evaluation of digital and conventional workflows for the fabrication of lithium disilicate single crowns. Part I: digital versus conventional unilateral impressions
    Benic, Goran I.
    Muhlemann, Sven
    Fehmer, Vincent
    Hammerle, Christoph H. F.
    Sailer, Irena
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (05) : 777 - 782
  • [33] Comparison of fit accuracy of pressed lithium disilicate inlays fabricated from wax or resin patterns with conventional and CAD-CAM technologies
    Homsy, Foudda R.
    Ozcan, Mutlu
    Khoury, Marwan
    Majzoub, Zeina A. K.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (04) : 530 - 536
  • [34] Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study
    Elrashid, Afra Hassan
    Alkahtani, Amjad Hamad
    Alqahtani, Shatha Jarallah
    Alajmi, Nouf Bali
    Alsultan, Fatimah Hussain
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2019, 9 (02) : 178 - 184
  • [35] Comparative evaluation of internal fit and marginal gap of endocrowns using lithium disilicate and polyether ether ketone materials-an in vitro study
    Nagi, Nermeen
    Fouda, Ahmed Mahmoud
    Bourauel, Christoph
    BMC ORAL HEALTH, 2023, 23 (01)
  • [36] Marginal accuracy of provisional crowns using three material systems and two techniques: A scanning electron microscope study
    Naqash, Talib Amin
    Alfarsi, Mohammed
    Hussain, Muhammad Waqar
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2019, 35 (01) : 55 - 60
  • [37] Accuracy of Proximal and Occlusal Contacts of Single Implant Crowns Fabricated Using Different Digital Scan Methods: An In Vitro Study
    Ren, Xi
    Son, Keunbada
    Lee, Kyu-Bok
    MATERIALS, 2021, 14 (11)
  • [38] Multivariate Assessment of Marginal Fit of Three Types of Dental Crowns Using Three Scanning Systems for CAD-CAM Technology - in vitro Pilot Study
    Buduru, Smaranda
    Mesaros, Anca
    Culcitchi, Cristian
    Moldovan, Marioara
    Prodan, Doina
    Szuhanek, Camelia
    MATERIALE PLASTICE, 2018, 55 (03) : 376 - 379
  • [39] Randomized controlled within-subject evaluation of digital and conventional workflows for the fabrication of lithium disilicate single crowns. Part II: CAD-CAM versus conventional laboratory procedures
    Sailer, Irena
    Benic, Goran I.
    Fehmer, Vincent
    Hammerle, Christoph H. F.
    Muhlemann, Sven
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (01) : 43 - 48
  • [40] Influence of two different cement space settings and three different cement types on the fit of polymer-infiltrated ceramic network material crowns manufactured using a complete digital workflow
    Dauti, Rinet
    Lilaj, Bledar
    Heimel, Patrick
    Moritz, Andreas
    Schedle, Andreas
    Cvikl, Barbara
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (06) : 1929 - 1938