Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging

被引:25
作者
Burkhard, Nina [1 ]
Herzog, Bernhard A. [1 ]
Husmann, Lars [1 ]
Pazhenkottil, Aju P. [1 ]
Burger, Irene A. [1 ]
Buechel, Ronny R. [1 ]
Valenta, Ines [1 ]
Wyss, Christophe A. [1 ]
Kaufmann, Philipp A. [1 ,2 ]
机构
[1] Univ Zurich Hosp, NUK C42, CH-8091 Zurich, Switzerland
[2] Univ Zurich, Zurich Ctr Integrat Human Physiol, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Attenuation correction; Coronary calcium score; PET; Myocardial blood flow; BLOOD-FLOW; ARTERY-DISEASE; O-15-LABELED WATER; ADENOSINE STRESS; BASE-LINE; REPRODUCIBILITY; QUANTIFICATION; TOMOGRAPHY; REPEATABILITY; VALIDATION;
D O I
10.1007/s00259-009-1271-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate whether ECG-triggered coronary calcium scoring (CCS) scans can be used for attenuation correction (AC) to quantify myocardial blood flow (MBF) and coronary flow reserve (CFR) assessed by PET/CT with N-13-ammonia. Thirty-five consecutive patients underwent a N-13-ammonia PET/CT scan at rest and during standard adenosine stress. MBF values were calculated using AC maps obtained from the ECG-triggered CCS scan during inspiration and validated against MBF values calculated using standard non-gated transmission scans for AC. CFR was calculated as the ratio of hyperaemic over resting MBF. In all 35 consecutive patients intraobserver variability was assessed by blinded repeat analysis for both AC methods. There was an excellent correlation between CT AC and CCS for global MBF values at rest (n = 35, r = 0.94, p < 0.001) and during stress (n = 35, r = 0.97, p < 0.001) with narrow Bland-Altman (BA) limits of agreement (-0.21 to 0.10 ml/min per g and -0.41 to 0.30 ml/min per g) as well as for global CFR (n = 35, r = 0.96, p < 0.001, BA -0.27 to 0.34). The excellent correlation was preserved on the segmental MBF analysis for both rest and stress (n = 1190, r = 0.93, p < 0.001, BA -0.60 to 0.50) and for CFR (n = 595, r = 0.87, p < 0.001, BA -0.71 to 0.74). In addition, reproducibility proved excellent for global CFR by CT AC (n = 35, r = 0.91, p < 0.001, BA -0.42-0.58) and CCS scans (n = 35, r = 0.94, p < 0.001, BA -0.34-0.45). Use of attenuation maps from CCS scans allows accurate quantitative MBF and CFR assessment with N-13-ammonia PET/CT.
引用
收藏
页码:517 / 521
页数:5
相关论文
共 23 条
  • [1] Assessment of myocardial perfusion by dynamic O-15-labeled water PET imaging: Validation of a new fast factor analysis
    Adachi, Itaru
    Gaemperli, Oliver
    Valenta, Ines
    Schepis, Tiziano
    Siegrist, Patrick T.
    Treyer, Valerie
    Burger, Cyrill
    Morita, Koichi
    Kaufmann, Philipp A.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (05) : 698 - 705
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    Burger, C
    Goerres, G
    Schoenes, S
    Buck, A
    Lonn, AHR
    von Schulthess, GK
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) : 922 - 927
  • [4] Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    Cerqueira, MD
    Weissman, NJ
    Dilsizian, V
    Jacobs, AK
    Kaul, S
    Laskey, WK
    Pennell, DJ
    Rumberger, JA
    Ryan, T
    Verani, MS
    [J]. CIRCULATION, 2002, 105 (04) : 539 - 542
  • [5] SAFETY PROFILE OF ADENOSINE STRESS PERFUSION IMAGING - RESULTS FROM THE ADENOSCAN-MULTICENTER-TRIAL-REGISTRY
    CERQUEIRA, MD
    VERANI, MS
    SCHWAIGER, M
    HEO, J
    ISKANDRIAN, AS
    ALAZRAKI, NP
    BEAN, LC
    BELARDINELLI, L
    BELL, M
    BERMAN, DS
    BOTVINICK, EH
    CHEIRIF, J
    HANSEN, CL
    HELLER, GV
    JOHNSTON, DL
    LEPPO, JA
    MADDAHI, J
    PARKER, LS
    MOHIUDDIN, S
    RAICHLEN, JS
    REIS, GJ
    SCHELBERT, HR
    SEALS, AA
    STOLZENBERG, J
    WILLIAMS, KA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) : 384 - 389
  • [6] Estimation of myocardial blood flow for longitudinal studies with N-13-labeled ammonia and positron emission tomography
    DeGrado, TR
    Hanson, MW
    Turkington, TG
    Delong, DM
    Brezinski, DA
    Vallee, JP
    Hedlund, LW
    Zhang, J
    Cobb, F
    Sullivan, MJ
    Coleman, RE
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1996, 3 (06) : 494 - 507
  • [7] Coronary calcium as a predictor of coronary events in four racial or ethnic groups
    Detrano, Robert
    Guerci, Alan D.
    Carr, J. Jeffrey
    Bild, Diane E.
    Burke, Gregory
    Folsom, Aaron R.
    Liu, Kiang
    Shea, Steven
    Szklo, Moyses
    Bluemke, David A.
    O'Leary, Daniel H.
    Tracy, Russell
    Watson, Karol
    Wong, Nathan D.
    Kronmal, Richard A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (13) : 1336 - 1345
  • [8] NONINVASIVE QUANTIFICATION OF REGIONAL BLOOD-FLOW IN THE HUMAN HEART USING N-13 AMMONIA AND DYNAMIC POSITRON EMISSION TOMOGRAPHIC IMAGING
    HUTCHINS, GD
    SCHWAIGER, M
    ROSENSPIRE, KC
    KRIVOKAPICH, J
    SCHELBERT, H
    KUHL, DE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (05) : 1032 - 1042
  • [9] Jagathesan R, 2005, J NUCL MED, V46, P212
  • [10] Kaufmann PA, 2005, J NUCL MED, V46, P75