The effects of digital image enhancement on the detection of vertical root fracture

被引:24
作者
Kamburoglu, Kivanc [1 ]
Murat, Sema [2 ]
Pehlivan, Selcen Yueksel [3 ]
机构
[1] Ankara Univ, Dept Oral Diag & Radiol, Fac Dent, TR-06100 Ankara, Turkey
[2] Ankara Univ, Dept Prosthet Dent, Fac Dent, TR-06100 Ankara, Turkey
[3] Ankara Univ, Dept Biostat, Fac Med, TR-06100 Ankara, Turkey
关键词
TREATED MAXILLARY PREMOLARS; CONVENTIONAL RADIOGRAPHY; APPROXIMAL CARIES; EX-VIVO; ACCURACY; DIAGNOSIS; LESIONS; FILM; STANDARD; FEATURES;
D O I
10.1111/j.1600-9657.2009.00841.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: To determine the effects of digital image enhancement on observer ability to detect experimentally induced vertical root fractures (VRF). Material and methods: A total of 64 extracted human mandibular premolar teeth were used in this study. In 32 teeth, VRFs were created in the bucco-lingual planes by gently tapping with screw-type root-canal pins. The remaining 32 intact teeth served as a control group. Digital images were obtained using a charge coupled device sensor. Three observers separately examined the original and four types of digitally enhanced images (enhanced using sharpness, zoom-in, reverse-contrast, and pseudo-3D functions) at 1-week intervals. All teeth were evaluated using a 5-point scale for the presence/absence of VRF. Evaluations of each image set were repeated 1 month after the initial viewings. Kappa coefficients were calculated to investigate the degree of intra- and inter-observer agreement. The areas under the receiver operating characteristic (ROC) curves (Az values) were calculated using the MedCalc statistical software. ROC values for each image type, observer and viewing were compared using t-tests. A level of alpha = 0.05 was considered significant. Results: Kappa coefficients for intra-observer agreement ranged from 0.304 to 0.679. Inter-observer agreement kappa values ranged from 0.109 to 0.399 for the first reading and from 0.106 to 0.380 for the second reading. Statistical comparisons between Az values for each observer showed no significant differences (P > 0.05) among image types. Conclusion: There were no differences in diagnostic outcomes among differently enhanced images in the in vitro detection of VRF.
引用
收藏
页码:47 / 51
页数:5
相关论文
共 27 条
[1]   Radiographic image enhancement. Part I: spatial domain techniques [J].
Analoui, M .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (01) :1-9
[2]  
Brullmann D, 2008, Int J Comput Dent, V11, P107
[3]  
DALE AM, DIGITAL XRAY IMAGING
[4]  
de Araujo EAF, 2005, AM J DENT, V18, P241
[5]   Digital radiography of interproximal caries: Effect of different filters [J].
Eickholz, P ;
Kolb, I ;
Lenhard, M ;
Hassfeld, S ;
Staehle, HJ .
CARIES RESEARCH, 1999, 33 (03) :234-241
[6]   An evaluation of endodontically treated vertical root fractured teeth: Impact of operative procedures [J].
Fuss, Z ;
Lustig, J ;
Katz, A ;
Tamse, A .
JOURNAL OF ENDODONTICS, 2001, 27 (01) :46-48
[7]   Effect of various digital processing algorithms on the measurement accuracy of endodontic file length [J].
Kal, Betul Ilhan ;
Baksi, B. Guniz ;
Dundar, Nesrin ;
Sen, Bilge Hakan .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (02) :280-284
[8]   Comparison of conventional film with different digital and digitally filtered images in the detection of simulated internal resorption cavities - an ex vivo study in human cadaver jaws [J].
Kamburoglu, Kivanc ;
Barenboim, Silvina Friedlander ;
Kaffe, Israel .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (06) :790-797
[9]   Accuracy of diagnosing occlusal caries using enhanced digital images [J].
Kositbowornchai, S ;
Basiw, M ;
Promwang, Y ;
Moragorn, H ;
Sooksuntisakoonchai, N .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (04) :236-240
[10]   Root fracture detection on digital images: effect of the zoom function [J].
Kositbowornchai, S ;
Sikram, S ;
Nuansakul, R ;
Thinkhamrop, B .
DENTAL TRAUMATOLOGY, 2003, 19 (03) :154-159