Improved Force Spectroscopy Using Focused-Ion-Beam-Modified Cantilevers

被引:14
|
作者
Faulk, J. K. [1 ,2 ]
Edwards, D. T. [1 ,2 ]
Bull, M. S. [1 ,2 ]
Perkins, T. T. [1 ,2 ]
机构
[1] NIST, JILA, Boulder, CO 80305 USA
[2] Univ Colorado, Boulder, CO 80309 USA
来源
SINGLE-MOLECULE ENZYMOLOGY: NANOMECHANICAL MANIPULATION AND HYBRID METHODS | 2017年 / 582卷
关键词
BIOLOGICAL APPLICATIONS; PROTEIN MOLECULE; SINGLE PROTEIN; MICROSCOPY; STABILITY; ADHESION; BONDS; TITIN;
D O I
10.1016/bs.mie.2016.08.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Atomic force microscopy (AFM) is widely used in biophysics, including force-spectroscopy studies of protein folding and protein-ligand interactions. The precision of such studies increases with improvements in the underlying quality of the data. Currently, data quality is limited by the mechanical properties of the cantilever when using a modern commercial AFM. The key tradeoff is force stability vs short-term force precision and temporal resolution. Here, we present a method that avoids this compromise: efficient focused-ion-beam (FIB) modification of commercially available cantilevers. Force precision is improved by reducing the cantilever's hydrodynamic drag, and force stability is improved by reducing the cantilever stiffness and by retaining a cantilever's gold coating only at its free end. When applied to a commonly used short cantilever (L = 40 mu m), we achieved sub-pN force precision over 5 decades of bandwidth (0.01-1000 Hz) without significantly sacrificing temporal resolution (similar to 75 mu s). Extending FIB modification to an ultrashort cantilever (L = 9 mu m) also improved force precision and stability, while maintaining 1-mu s-scale temporal resolution. Moreover, modifying ultrashort cantilevers also eliminated their inherent underdamped high-frequency motion and thereby avoided applying a rapidly oscillating force across the stretched molecule. Importantly, fabrication of FIB-modified cantilevers is accessible after an initial investment in training. Indeed, undergraduate researchers routinely modify 2-4 cantilevers per hour with the protocol detailed here. Furthermore, this protocol offers the individual user the ability to optimize a cantilever for a particular application. Hence, we expect FIB-modified cantilevers to improve AFM-based studies over broad areas of biophysical research.
引用
收藏
页码:321 / 351
页数:31
相关论文
共 50 条
  • [42] FOCUSED ION-BEAM USING A TRIODE GUN
    KOMURO, M
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (03) : C110 - C110
  • [43] Wafer diagnostics using focused ion beam technology
    Kratzer, Dean
    Talbot, Christopher
    EE: Evaluation Engineering, 1993, 32 (08): : 72 - 75
  • [44] Wedge emitter fabrication using focused ion beam
    Ochiai, C
    Sawada, A
    Noriyasu, H
    Takai, M
    Hosono, A
    Okuda, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2001, 19 (03): : 904 - 906
  • [45] 'Nano-machining' using a focused ion beam
    Campbell, LCI
    Foord, DT
    Humphreys, CJ
    ELECTRON MICROSCOPY AND ANALYSIS 1997, 1997, (153): : 657 - 660
  • [46] Rapid serial prototyping of magnet-tipped attonewton-sensitivity cantilevers by focused ion beam manipulation
    Longenecker, Jonilyn G.
    Moore, Eric W.
    Marohn, John A.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2011, 29 (03):
  • [47] Using electron spectroscopy to verify the model of Ga implanted during focused ion beam circuit editing
    Niles, David W.
    Spicer, Teresa
    Kee, Ronald W.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2012, 30 (06):
  • [48] Study of iron-chromium alloys and mixed oxides using focused ion beam optical spectroscopy
    Su, RJH
    Allen, GC
    Heard, PJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (08) : 799 - 801
  • [49] Improved focused ion beam fabrication of near-field apertures using a silicon nitride membrane
    Leen, J. Brian
    Hansen, Paul
    Cheng, Yao-Te
    Hesselink, Lambertus
    OPTICS LETTERS, 2008, 33 (23) : 2827 - 2829
  • [50] Focused ion beam irradiation of ZnO film: an atomic force microscopy study
    Qian, H. X.
    Zhou, Wei
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2009, 42 (10)