Improved Force Spectroscopy Using Focused-Ion-Beam-Modified Cantilevers

被引:14
|
作者
Faulk, J. K. [1 ,2 ]
Edwards, D. T. [1 ,2 ]
Bull, M. S. [1 ,2 ]
Perkins, T. T. [1 ,2 ]
机构
[1] NIST, JILA, Boulder, CO 80305 USA
[2] Univ Colorado, Boulder, CO 80309 USA
来源
SINGLE-MOLECULE ENZYMOLOGY: NANOMECHANICAL MANIPULATION AND HYBRID METHODS | 2017年 / 582卷
关键词
BIOLOGICAL APPLICATIONS; PROTEIN MOLECULE; SINGLE PROTEIN; MICROSCOPY; STABILITY; ADHESION; BONDS; TITIN;
D O I
10.1016/bs.mie.2016.08.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Atomic force microscopy (AFM) is widely used in biophysics, including force-spectroscopy studies of protein folding and protein-ligand interactions. The precision of such studies increases with improvements in the underlying quality of the data. Currently, data quality is limited by the mechanical properties of the cantilever when using a modern commercial AFM. The key tradeoff is force stability vs short-term force precision and temporal resolution. Here, we present a method that avoids this compromise: efficient focused-ion-beam (FIB) modification of commercially available cantilevers. Force precision is improved by reducing the cantilever's hydrodynamic drag, and force stability is improved by reducing the cantilever stiffness and by retaining a cantilever's gold coating only at its free end. When applied to a commonly used short cantilever (L = 40 mu m), we achieved sub-pN force precision over 5 decades of bandwidth (0.01-1000 Hz) without significantly sacrificing temporal resolution (similar to 75 mu s). Extending FIB modification to an ultrashort cantilever (L = 9 mu m) also improved force precision and stability, while maintaining 1-mu s-scale temporal resolution. Moreover, modifying ultrashort cantilevers also eliminated their inherent underdamped high-frequency motion and thereby avoided applying a rapidly oscillating force across the stretched molecule. Importantly, fabrication of FIB-modified cantilevers is accessible after an initial investment in training. Indeed, undergraduate researchers routinely modify 2-4 cantilevers per hour with the protocol detailed here. Furthermore, this protocol offers the individual user the ability to optimize a cantilever for a particular application. Hence, we expect FIB-modified cantilevers to improve AFM-based studies over broad areas of biophysical research.
引用
收藏
页码:321 / 351
页数:31
相关论文
共 50 条
  • [21] High-speed force spectroscopy: microsecond force measurements using ultrashort cantilevers
    Valotteau C.
    Sumbul F.
    Rico F.
    Biophysical Reviews, 2019, 11 (5) : 689 - 699
  • [22] Optimizing force spectroscopy by modifying commercial cantilevers: Improved stability, precision, and temporal resolution
    Edwards, Devin T.
    Perkins, Thomas T.
    JOURNAL OF STRUCTURAL BIOLOGY, 2017, 197 (01) : 13 - 25
  • [23] Carbon nanotube-modified cantilevers for improved spatial resolution in electrostatic force microscopy
    Arnason, SB
    Rinzler, AG
    Hudspeth, Q
    Hebard, AF
    APPLIED PHYSICS LETTERS, 1999, 75 (18) : 2842 - 2844
  • [24] Sculpting on polymers using focused ion beam
    Moon, M. -W.
    Her, E. -K.
    Oh, K. H.
    Lee, K-R.
    Vaziri, A.
    SURFACE & COATINGS TECHNOLOGY, 2008, 202 (22-23): : 5319 - 5324
  • [25] The nanofabrication of polydimethylsiloxane using a focused ion beam
    Guan, Li
    Peng, Kaiwu
    Yang, Yanlian
    Qiu, Xiaohui
    Wang, Chen
    NANOTECHNOLOGY, 2009, 20 (14)
  • [26] MICROMACHINING USING A FOCUSED ION-BEAM
    YOUNG, RJ
    VACUUM, 1993, 44 (3-4) : 353 - 356
  • [27] Ferroelectric nanostructures via a modified focused ion beam technique
    Nagarajan, V
    Stanishevsky, A
    Ramesh, R
    NANOTECHNOLOGY, 2006, 17 (01) : 338 - 343
  • [28] Ion beam synthesis of cobalt disilicide using focused ion beam implantation
    Teichert, J
    Bischoff, L
    Hausmann, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1998, 16 (04): : 2574 - 2577
  • [29] Force spectroscopy based on temperature controlled atomic force microscope head using piezoresistive cantilevers
    Musevic, I
    Kocevar, K
    Krzic, U
    Carbone, G
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (04):
  • [30] The use of Auger spectroscopy and a quadrupole SIMS build on a focused ion beam to examine focused ion beam made cross-sections
    Verkleij, D
    Mulders, C
    MICRON, 1999, 30 (03) : 227 - 234