Prediction of Effective Lens Position by Reference to the Preoperative Axial Length

被引:0
|
作者
Kim, Gee-Hyun [1 ]
Whang, Woong-Joo [1 ]
Kim, Hyun-Seung [2 ]
机构
[1] Catholic Univ Korea, Coll Med, Dept Ophthalmol, Yeouido St Marys Hosp, 10 63 Ro, Seoul 07345, South Korea
[2] Catholic Univ Korea, Coll Med, Dept Ophthalmol, Seoul St Marys Hosp, Seoul, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2021年 / 62卷 / 03期
关键词
Axial length; Anterior chamber depth; Corneal power; Cataract surgery; Effective lens position;
D O I
10.3341/jkos.2021.62.3.308
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We derived optimal formulae permitting effective lens position (ELP) for patients differing in terms of their preoperative axial lengths as revealed by partial coherence interferometry. Methods: We included 736 eyes from 736 patients who underwent conventional cataract surgery at Yeouido St. Mary's Hospital. The preoperative axial length (AL), corneal power (CP), and anterior chamber depth (ACD) measured via partial coherence interferometry served as independent variables for ELP prediction. The 736 eyes were divided into seven groups differing by 1.0-mm intervals in terms of the preoperative axial length. We sought correlations between the independent variables and the ELP, and defined the combinations that best predicted the ELPs of the seven groups. Results: The CP correlated significantly with the ELP for eyes with AL between 22.0 and 25.0 mm (all p < 0.01) and the ACD correlated significantly with the ELP for eyes with AL between 23.0 and 26.0 mm (all p < 0.01). Although a regression equation featuring all of the AL, ACD, and CP best predicted the ELP for the total of 736 eyes (p < 0.001), the optimal combination varied by the preoperative AL. Conclusions: The effects of CP, ACD, and AL on ELP vary by the preoperative AL. The optimal combination of preoperative variables predicting ELP thus varies as that parameter changes.
引用
收藏
页码:308 / 314
页数:7
相关论文
共 50 条
  • [21] Prediction of postoperative effective lens position using iris root depth in primary angle-closure diseases
    Ding, Yujie
    Hou, Min
    Liu, Liangping
    Mao, Yan
    Liu, Xing
    Wu, Mingxing
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (07) : 691 - 696
  • [22] Prediction of effective Lens position using anterior segment optical coherence tomography in Chinese subjects with angle closure
    Yuzhou Wu
    Shunhua Zhang
    Yong Zhong
    Ailing Bian
    Yang Zhang
    Zaowen Wang
    BMC Ophthalmology, 21
  • [23] Prediction of effective Lens position using anterior segment optical coherence tomography in Chinese subjects with angle closure
    Wu, Yuzhou
    Zhang, Shunhua
    Zhong, Yong
    Bian, Ailing
    Zhang, Yang
    Wang, Zaowen
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [24] The Effect of Orthokeratology Lens on the Axial Length of Globe in Children with Myopia in Asia
    Yang, Guang
    Tang, Shaohua
    Li, Qingnan
    Xu, Lanfang
    Liu, Shuang
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2022, 32 (11): : 1459 - 1464
  • [25] Associations of lens thickness and axial length with outcomes of laser peripheral iridotomy
    Liu, Ya-Meng
    Hu, Die
    Zhou, Long-Fang
    Lan, Jie
    Feng, Cheng-Cheng
    Wang, Xiao-Yun
    Pan, Xiao-Jing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (05) : 714 - 718
  • [26] Associations of lens thickness and axial length with outcomes of laser peripheral iridotomy
    Ya-Meng Liu
    Die Hu
    Long-Fang Zhou
    Jie Lan
    Cheng-Cheng Feng
    Xiao-Yun Wang
    Xiao-Jing Pan
    International Journal of Ophthalmology, 2021, 14 (05) : 714 - 718
  • [27] Prediction of Implantable Collamer Lens Vault Based on Preoperative Biometric Factors and Lens Parameters
    Di, Yu
    Li, Ying
    Luo, Yan
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (05) : 332 - +
  • [28] Evaluation of the postoperative axial lens position and refractive correction of a hydrophobic one-piece intraocular lens
    Mihalics, Stefan
    Stattin, Martin
    Graf, Alexandra
    Kickinger, Stefan
    Angermann, Reinhard
    Krepler, Katharina
    Ansari-Shahrezaei, Siamak
    SPEKTRUM DER AUGENHEILKUNDE, 2023, 37 (04) : 85 - 91
  • [29] Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth
    Gao, Ruoxi
    Zhang, Jiaqing
    Han, Xiaotong
    Huang, Yiguo
    Huang, Ruoxuan
    Ye, Jinfeng
    Wen, Ling
    Qiu, Xiaozhang
    Chen, Xiaoyun
    Tan, Xuhua
    Luo, Lixia
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [30] Algorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length
    Kim, Jung Wan
    Eom, Youngsub
    Yoon, Eun Gyu
    Choi, Young
    Song, Jong Suk
    Jeong, Ji Won
    Park, Seh Kwang
    Kim, Hyo Myung
    ACTA OPHTHALMOLOGICA, 2022, 100 (03) : E701 - E709