Simulations of voltage clamping poorly space-clamped voltage-dependent conductances in a uniform cylindrical neurite

被引:17
作者
Hartline, DK [1 ]
Castelfranco, AM [1 ]
机构
[1] Univ Hawaii Manoa, Pacific Biomed Res Ctr, Bekesy Lab Neurobiol, Honolulu, HI 96822 USA
基金
美国国家科学基金会;
关键词
voltage-clamp; space-clamp errors; Hodgkin-Huxley conductances; isochronal I (V) curves; computational nerve modeling;
D O I
10.1023/A:1023208926805
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Significant error is made by using a point voltage clamp to measure active ionic current properties in poorly space-clamped cells. This can even occur when there are no obvious signs of poor spatial control. We evaluated this error for experiments that employ an isochronal I (V) approach to analyzing clamp currents. Simulated voltage clamp experiments were run on a model neuron having a uniform distribution of a single voltage-gated inactivating ionic current channel along an elongate, but electrotonically compact, process. Isochronal Boltzmann I (V) and kinetic parameter values obtained by fitting the Hodgkin-Huxley equations to the clamp currents were compared with the values originally set in the model. Good fits were obtained for both inward and outward currents for moderate channel densities. Most parameter errors increased with conductance density. The activation rate parameters were more sensitive to poor space clamp than the I (V) parameters. Large errors can occur despite "normal"-looking clamp curves.
引用
收藏
页码:253 / 269
页数:17
相关论文
共 33 条
[2]  
[Anonymous], 1986, NUMERICAL RECIPES C
[3]  
ARMSTRONG CM, 1992, METHOD ENZYMOL, V207, P100
[4]  
Castelfranco A. M., 2001, Society for Neuroscience Abstracts, V27, P1936
[5]   Simulations of space-clamp errors in estimating parameters of voltage-gated conductances localized at different electrotonic distances [J].
Castelfranco, AM ;
Hartline, DK .
NEUROCOMPUTING, 2002, 44 :75-80
[6]   THE SYNAPTIC CURRENT EVOKED IN CAT SPINAL MOTONEURONES BY IMPULSES IN SINGLE GROUP-1A AXONS [J].
FINKEL, AS ;
REDMAN, SJ .
JOURNAL OF PHYSIOLOGY-LONDON, 1983, 342 (SEP) :615-632
[7]  
Hartline D. K., 1995, Society for Neuroscience Abstracts, V21, P63
[8]   EFFECTS OF SOMA ISOLATION ON OUTWARD CURRENTS MEASURED UNDER VOLTAGE-CLAMP IN SPINY LOBSTER STOMATOGASTRIC MOTOR-NEURONS [J].
HARTLINE, DK ;
GASSIE, DV ;
JONES, BR .
JOURNAL OF NEUROPHYSIOLOGY, 1993, 69 (06) :2056-2071
[9]   A PROGRAM FOR SIMULATION OF NERVE EQUATIONS WITH BRANCHING GEOMETRIES [J].
HINES, M .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1989, 24 (01) :55-68
[10]  
Hines M., 1993, NEURAL SYSTEMS ANAL, P127