HV Floating Switch Matrix with Parachute Safety Driving for 3D Echography Systems

被引:0
作者
Ricotti, Giulio [1 ]
Bottarel, Valeria [1 ]
机构
[1] Smart Power & High Voltage Technol R&D, Cornaredo, Italy
来源
2018 48TH EUROPEAN SOLID-STATE DEVICE RESEARCH CONFERENCE (ESSDERC) | 2018年
关键词
multiplexer; switches; high voltage; linearity; ultrasound; echography; pulser; floating; DMOS; slew rate;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper describes the design challenges and solutions studied and implemented in high voltage (HV) bidirectional and floating switch. The main characteristics are the isolation voltage up to positive and negative 200V, ultra-low power consumption for switch driving, fully floating at high slew rate up to 30V/ns. The final IC integrates a matrix of 512 (8x64) independent HV switch, the other important requirement is the minimal area.
引用
收藏
页码:215 / 217
页数:3
相关论文
共 30 条
[1]   HV Floating Switch Matrix with Parachute Safety Driving for 3D Echography Systems [J].
Ricotti, Giulio ;
Bottarel, Valeria .
ESSCIRC 2018 - IEEE 44TH EUROPEAN SOLID STATE CIRCUITS CONFERENCE (ESSCIRC), 2018, :271-273
[2]   TOWARDS 3D SYNTHETIC APERTURE RADAR ECHOGRAPHY [J].
Fiscante, N. ;
Biondi, F. ;
Forlingieri, F. ;
Addabbo, Pia ;
Clemente, C. ;
Giunta, G. ;
Orlando, D. .
2022 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2022), 2022, :955-958
[3]   A 3D FEM model for floating wind turbines support structures [J].
Campos, A. ;
Molins, C. ;
Trubat, P. ;
Alarcon, D. .
14TH DEEP SEA OFFSHORE WIND R&D CONFERENCE, EERA DEEPWIND'2017, 2017, 137 :177-185
[4]   3D/4D sonography - any safety problem [J].
Pooh, Ritsuko K. ;
Maeda, Kazuo ;
Kurjak, Asim ;
Sen, Cihat ;
Ebrashy, Alaa ;
Adra, Abdallah ;
Dayyabu, Aliyu Labaran ;
Wataganara, Tuangsit ;
Moreira de Sa, Renato Augusto ;
Stanojevic, Milan .
JOURNAL OF PERINATAL MEDICINE, 2016, 44 (02) :125-129
[5]   A floating 3D printed polypill formulation for the coadministration and sustained release of antihypertensive drugs [J].
Zgouro, Paola ;
Katsamenis, Orestis L. ;
Moschakis, Thomas ;
Eleftheriadis, Georgios K. ;
Kyriakidis, Athanasios S. ;
Chachlioutaki, Konstantina ;
Monou, Paraskevi Kyriaki ;
Ntorkou, Marianna ;
Zacharis, Constantinos K. ;
Bouropoulos, Nikolaos ;
Fatouros, Dimitrios G. ;
Karavasili, Christina ;
Gioumouxouzis, Christos I. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 655
[6]   2D matrix array optimization by simulated annealing for 3D hepatic imaging [J].
Diarra, Bakary ;
Liebgott, Herve ;
Tortoli, Piero ;
Cachard, Christian .
2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, :1595-1598
[7]   Application of 3D field analysis for modelling the electric field distribution in ceramic insulator of HV combined instrument transformer [J].
Lesniewska, E .
JOURNAL OF ELECTROSTATICS, 2001, 51 (1-4) :610-617
[8]   Using particle systems for mitral valve segmentation from 3D transoesophageal echocardiography (3D TOE) - a proof of concept [J].
Lopes, Patricia ;
Van Herck, Paul ;
Verhoelst, Eefje ;
Wirix-Speetjens, Roel ;
Sijbers, Jan ;
Bosmans, Johan ;
Vander Sloten, Jos .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (01) :112-120
[9]   Volumetry of Fetal Hearts using 3D Real-Time Matrix Echocardiography - In Vitro Validation Experiments and 3D Echocardiographic Studies in Fetuses [J].
Herberg, U. ;
Lueck, S. ;
Steinweg, B. ;
Brand, M. ;
Knies, R. ;
Geipel, A. ;
Trier, H. G. ;
Breuer, J. .
ULTRASCHALL IN DER MEDIZIN, 2011, 32 (01) :46-53
[10]   Real Time 3D Adaptive Filtering for Portable Imaging Systems [J].
Bockenbach, Olivier ;
Ali, Murtaza ;
Wainwright, Ian ;
Nadeski, Mark .
IMAGE PROCESSING: ALGORITHMS AND SYSTEMS XIII, 2015, 9399