摘要
The paper describes the design challenges and solutions studied and implemented in high voltage (HV) bidirectional and floating switch. The main characteristics are the isolation voltage up to positive and negative 200V, ultra-low power consumption for switch driving, fully floating at high slew rate up to 30V/ns. The final IC integrates a matrix of 512 (8x64) independent HV switch, the other important requirement is the minimal area.
引用
收藏
页码:215 / 217
页数:3
相关论文
共 30 条
  • [1] HV Floating Switch Matrix with Parachute Safety Driving for 3D Echography Systems
    Ricotti, Giulio
    Bottarel, Valeria
    ESSCIRC 2018 - IEEE 44TH EUROPEAN SOLID STATE CIRCUITS CONFERENCE (ESSCIRC), 2018, : 271 - 273
  • [2] TOWARDS 3D SYNTHETIC APERTURE RADAR ECHOGRAPHY
    Fiscante, N.
    Biondi, F.
    Forlingieri, F.
    Addabbo, Pia
    Clemente, C.
    Giunta, G.
    Orlando, D.
    2022 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2022), 2022, : 955 - 958
  • [3] A 3D FEM model for floating wind turbines support structures
    Campos, A.
    Molins, C.
    Trubat, P.
    Alarcon, D.
    14TH DEEP SEA OFFSHORE WIND R&D CONFERENCE, EERA DEEPWIND'2017, 2017, 137 : 177 - 185
  • [4] 3D/4D sonography - any safety problem
    Pooh, Ritsuko K.
    Maeda, Kazuo
    Kurjak, Asim
    Sen, Cihat
    Ebrashy, Alaa
    Adra, Abdallah
    Dayyabu, Aliyu Labaran
    Wataganara, Tuangsit
    Moreira de Sa, Renato Augusto
    Stanojevic, Milan
    JOURNAL OF PERINATAL MEDICINE, 2016, 44 (02) : 125 - 129
  • [5] A floating 3D printed polypill formulation for the coadministration and sustained release of antihypertensive drugs
    Zgouro, Paola
    Katsamenis, Orestis L.
    Moschakis, Thomas
    Eleftheriadis, Georgios K.
    Kyriakidis, Athanasios S.
    Chachlioutaki, Konstantina
    Monou, Paraskevi Kyriaki
    Ntorkou, Marianna
    Zacharis, Constantinos K.
    Bouropoulos, Nikolaos
    Fatouros, Dimitrios G.
    Karavasili, Christina
    Gioumouxouzis, Christos I.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 655
  • [6] 2D matrix array optimization by simulated annealing for 3D hepatic imaging
    Diarra, Bakary
    Liebgott, Herve
    Tortoli, Piero
    Cachard, Christian
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 1595 - 1598
  • [7] Application of 3D field analysis for modelling the electric field distribution in ceramic insulator of HV combined instrument transformer
    Lesniewska, E
    JOURNAL OF ELECTROSTATICS, 2001, 51 (1-4) : 610 - 617
  • [8] Using particle systems for mitral valve segmentation from 3D transoesophageal echocardiography (3D TOE) - a proof of concept
    Lopes, Patricia
    Van Herck, Paul
    Verhoelst, Eefje
    Wirix-Speetjens, Roel
    Sijbers, Jan
    Bosmans, Johan
    Vander Sloten, Jos
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (01) : 112 - 120
  • [9] Volumetry of Fetal Hearts using 3D Real-Time Matrix Echocardiography - In Vitro Validation Experiments and 3D Echocardiographic Studies in Fetuses
    Herberg, U.
    Lueck, S.
    Steinweg, B.
    Brand, M.
    Knies, R.
    Geipel, A.
    Trier, H. G.
    Breuer, J.
    ULTRASCHALL IN DER MEDIZIN, 2011, 32 (01): : 46 - 53
  • [10] Real Time 3D Adaptive Filtering for Portable Imaging Systems
    Bockenbach, Olivier
    Ali, Murtaza
    Wainwright, Ian
    Nadeski, Mark
    IMAGE PROCESSING: ALGORITHMS AND SYSTEMS XIII, 2015, 9399