Clinically feasible NODDI characterization of glioma using multiband EPI at 7 T

被引:65
作者
Wen, Qiuting [1 ,2 ]
Kelley, Douglas A. C. [3 ]
Banerjee, Suchandrima [4 ]
Lupo, Janine M. [2 ]
Chang, Susan M. [5 ]
Xu, Duan [2 ]
Hess, Christopher P. [2 ]
Nelson, Sarah J. [1 ,2 ,6 ]
机构
[1] Univ Calif San Francisco, UCSF UCB Joint Grad Grp Bioengn, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[3] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA USA
[4] GE Healthcare, Global Appl Sci Lab, San Francisco, CA USA
[5] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA USA
[6] Univ Calif San Francisco, Dept Bioengn & Therapeut Sci, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
Multiband EPI; 7; Tesla; NODDI; Glioma; SNR; NEURITE ORIENTATION DISPERSION; MULTISHELL DIFFUSION MRI; EXCITATION; MICROSTRUCTURE; RECONSTRUCTION; IMAGES;
D O I
10.1016/j.nicl.2015.08.017
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Recent technological progress in the multiband echo planer imaging (MB EPI) technique enables accelerated MR diffusion weighted imaging (DWI) and allows whole brain, multi-b-value diffusion imaging to be acquired within a clinically feasible time. However, its applications at 7 T have been limited due to B1 field inhomogeneity and increased susceptibility artifact. It is an ongoing debate whether DWI at 7 T can be performed properly in patients, and a systematic SNR comparison for multiband spin-echo EPI between 3 T and 7 T has not been methodically studied. The goal of this study was to use MB EPI at 7 T in order to obtain 90-directional multi-shell DWI within a clinically feasible acquisition time for patients with glioma. This study included an SNR comparison between 3 T and 7 T, and the application of B1 mapping and distortion correction procedures for reducing the impact of variations in B0 and B1. The optimized multiband sequence was applied in 20 patients with glioma to generate both DTI and NODDI maps for comparison of values in tumor and normal appearing white matter (NAWM). Our SNR analysis showed that MB EPI at 7 T was comparable to that at 3 T, and the data quality acquired in patients was clinically acceptable. NODDI maps provided unique contrast within the T2 lesion that was not seen in anatomical images or DTI maps. Such contrast may reflect the complexity of tissue compositions associated with disease progression and treatment effects. The ability to consistently obtain high quality diffusion data at 7 T will contribute towards the implementation of a comprehensive brain MRI examination at ultra-high field. (C) 2015 Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:291 / 299
页数:9
相关论文
共 43 条
[21]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO
[22]  
2-S
[23]   Diffusion MRI in multiple sclerosis [J].
Rovaris, M ;
Gass, A ;
Bammer, R ;
Hickman, SJ ;
Ciccarelli, O ;
Miller, DH ;
Filippi, M .
NEUROLOGY, 2005, 65 (10) :1526-1532
[24]  
Schneider T., 2014, P 22 SCI M ISMRM MIL, P19
[25]   Pushing the limits of in vivo diffusion MRI for the Human Connectome Project [J].
Setsompop, K. ;
Kimmlingen, R. ;
Eberlein, E. ;
Witzel, T. ;
Cohen-Adad, J. ;
McNab, J. A. ;
Keil, B. ;
Tisdall, M. D. ;
Hoecht, P. ;
Dietz, P. ;
Cauley, S. F. ;
Tountcheva, V. ;
Matschl, V. ;
Lenz, V. H. ;
Heberlein, K. ;
Potthast, A. ;
Thein, H. ;
Van Horn, J. ;
Toga, A. ;
Schmitt, F. ;
Lehne, D. ;
Rosen, B. R. ;
Wedeen, V. ;
Wald, L. L. .
NEUROIMAGE, 2013, 80 :220-233
[26]   Blipped-controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty [J].
Setsompop, Kawin ;
Gagoski, Borjan A. ;
Polimeni, Jonathan R. ;
Witzel, Thomas ;
Wedeen, Van J. ;
Wald, Lawrence L. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) :1210-1224
[27]   Low peak power multiband spokes pulses for B1+ inhomogeneity-compensated simultaneous multislice excitation in high field MRI [J].
Sharma, Anuj ;
Bammer, Roland ;
Stenger, V. Andrew ;
Grissom, William A. .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (03) :747-755
[28]   Advances in functional and structural MR image analysis and implementation as FSL [J].
Smith, SM ;
Jenkinson, M ;
Woolrich, MW ;
Beckmann, CF ;
Behrens, TEJ ;
Johansen-Berg, H ;
Bannister, PR ;
De Luca, M ;
Drobnjak, I ;
Flitney, DE ;
Niazy, RK ;
Saunders, J ;
Vickers, J ;
Zhang, YY ;
De Stefano, N ;
Brady, JM ;
Matthews, PM .
NEUROIMAGE, 2004, 23 :S208-S219
[29]   Advances in diffusion MRI acquisition and processing in the Human Connectome Project [J].
Sotiropoulos, Stamatios N. ;
Jbabdi, Saad ;
Xu, Junqian ;
Andersson, Jesper L. ;
Moeller, Steen ;
Auerbach, Edward J. ;
Glasser, Matthew F. ;
Hernandez, Moises ;
Sapiro, Guillermo ;
Jenkinson, Mark ;
Feinberg, David A. ;
Yacoub, Essa ;
Lenglet, Christophe ;
Van Essen, David C. ;
Ugurbil, Kamil ;
Behrens, Timothy E. J. .
NEUROIMAGE, 2013, 80 :125-143
[30]  
Stummer Walter, 2007, Neurosurg Focus, V22, pE8, DOI 10.3171/foc.2007.22.5.9