Indoor air quality in Michigan schools

被引:185
作者
Godwin, C. [1 ]
Batterman, S. [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
indoor air quality; schools; volatile organic compounds; bioaerosols; ventilation; exposure assessment;
D O I
10.1111/j.1600-0668.2006.00459.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality (IAQ) parameters in 64 elementary and middle school classrooms in Michigan were examined for the purposes of assessing ventilation rates, levels of volatile organic compounds (VOCs) and bioaerosols, air quality differences within and between schools, and emission sources. In each classroom, bioaerosols, VOCs, CO2, relative humidity, and temperature were monitored over one workweek, and a comprehensive walkthough survey was completed. Ventilation rates were derived from CO2 and occupancy data. Ventilation was poor in many of the tested classrooms, e.g., CO2 concentrations often exceeded 1000 ppm and sometimes 3000 ppm. Most VOCs had low concentrations (mean of individual species < 4.5 mu g/m(3)); bioaerosol concentrations were moderate (< 6500 count per m(3) indoors, < 41,000 count per m(3) outdoors). The variability of CO2, VOC, and bioaerosol concentrations within schools exceeded the variability between schools. These findings suggest that none of the sampled rooms were contaminated and that no building-wide contamination sources were present. However, localized IAQ problems might remain in spaces where contaminant sources are concentrated and that are poorly ventilated.
引用
收藏
页码:109 / 121
页数:13
相关论文
共 24 条
[1]   TVOC and health in non-industrial indoor environments - Report from a Nordic scientific consensus meeting at Langholmen in Stockholm, 1996 [J].
Andersson, K ;
Bakke, JV ;
Bjorseth, O ;
Bornehag, CG ;
Clausen, G ;
Hongslo, JK ;
Kjellman, M ;
Kjaergaard, S ;
Levy, F ;
Molhave, L ;
Skerfving, S ;
Sundell, J .
INDOOR AIR, 1997, 7 (02) :78-91
[2]  
[Anonymous], GAOHEHS96103
[3]  
ASHRAE, 2001, 622001 ASHRAE
[4]  
*ASHRAE, 1993, ASHRAE HDB FUND I P
[5]   Low-flow active and passive sampling of VOCs using thermal desorption tubes: theory and application at an offset printing facility [J].
Batterman, S ;
Metts, T ;
Kalliokoski, P ;
Barnett, E .
JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (03) :361-370
[6]   The role and abatement of fungal allergens in allergic diseases [J].
Bush, RK ;
Portnoy, JM .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2001, 107 (03) :S430-S440
[7]  
CARRER P, 2002, P IND AIR 2002, V2, P794
[8]   Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information [J].
Daisey, JM ;
Angell, WJ ;
Apte, MG .
INDOOR AIR, 2003, 13 (01) :53-64
[9]  
*GAO, 1995, GAOHEHS9561
[10]  
Kinshella M R, 2001, Appl Occup Environ Hyg, V16, P952