Replacement of electric resistive space heating by an air-source heat pump in a residential application. Environmental amortization

被引:27
作者
Latorre-Biel, Juan-Ignacio [1 ]
Jimemez, Esther [2 ]
Garcia, Jorge L. [3 ]
Martinez, Eduardo [2 ]
Jimenez, Emilio [2 ]
Blanco, Julio [2 ]
机构
[1] Univ Publ Navarra, Dept Mech Energy & Mat Engn, Campus Tudela,Avda Tarazona S-N, Tudela 31500, Spain
[2] Univ La Rioja, Dept Mech Engn, Edificio Dept,C San Jose de Calasanz 31, Logrono, La Rioja, Spain
[3] Autonomous Univ Ciudad Juarez, Dept Ind Engn & Mfg, Inst Engn & Technol, Av Charro 450 Norte, Ciudad Juarez, Chihuahua, Mexico
关键词
Life cycle assessment (LCA); Air source heat pump (ASHP); Environmental analysis and amortization; All-electric boilers; Low-temperature radiators; Underfloor heating; IMPACT; LCA; ENERGY; DESIGN; SYSTEM; PLANT;
D O I
10.1016/j.buildenv.2018.05.060
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
All-electric boilers and air source heat pumps are both powered by electric energy. However, each kWh of heat that is produced implies higher electric consumption in the former. Therefore, as a consequence of financial issues, users of all-electric boilers might afford the substitution of this heating device by an air source heat pump (ASHP). In this paper, a particular facet of this replacement is analyzed, its environmental impact, providing with a deeper insight in the consequences of this substitution. A life cycle assessment of the replacement of an all-electric boiler by an ASHP is described, using 11 environmental impact categories and three different heat emitters, such as underfloor heating, low temperature radiators and conventional radiators. As a consequence of this analysis, it has been found that, in most of the categories, the energy savings from the replacement compensate the environmental impact of the ASHP. This trend is more evident with underfloor heating than radiators. Additionally, the environmental amortization of this replacement has also been analyzed. The results of this study show that the environmental amortization can be achieved by an ASHP with underfloor heating during a conservative lifespan of 10 years in all the impact categories. Other heat emitters may require between 33% and 45% more time to reach the environmental amortization.
引用
收藏
页码:193 / 205
页数:13
相关论文
共 29 条
[1]   Experimental and simulation studies on air source heat pump water heater for year-round applications in Canada [J].
Amirirad, Afarin ;
Kumar, Rakesh ;
Fung, Alan S. ;
Leong, Wey H. .
ENERGY AND BUILDINGS, 2018, 165 :141-149
[2]  
[Anonymous], LIFE CYCLE ASSESSMEN
[3]  
Beurskens LWM, 2011, RENEWABLE ENERGY PRO, P244
[4]   Modeling Green Logistics [J].
Bruzzone, Agostino G. ;
Tremori, Alberto ;
Massei, Marina ;
Tarone, Federico .
2009 THIRD ASIA INTERNATIONAL CONFERENCE ON MODELLING & SIMULATION, VOLS 1 AND 2, 2009, :543-+
[5]   Technical and environmental effects of concrete production: dry batch versus central mixed plant [J].
Cazacliu, Bogdan ;
Ventura, Anne .
JOURNAL OF CLEANER PRODUCTION, 2010, 18 (13) :1320-1327
[6]   Energy and environmental implications of using geothermal heat pumps in buildings: An example from north China [J].
Chang, Yuan ;
Gu, Yurong ;
Zhang, Lixiao ;
Wu, Chuyi ;
Liang, Liang .
JOURNAL OF CLEANER PRODUCTION, 2017, 167 :484-492
[7]  
Ciarrocchi E., 2017, ASSESSMENT ENERGY PE, P439
[8]   Meta-analysis of European heat pump field trial efficiencies [J].
Gleeson, Colin Patrick ;
Lowe, Robert .
ENERGY AND BUILDINGS, 2013, 66 :637-647
[9]   Methodological approach towards sustainability by integration of environmental impact in production system models through life cycle analysis: Application to the Rioja wine sector [J].
Jimenez, Emilio ;
Martinez, Eduardo ;
Blanco, Julio ;
Perez, Mercedes ;
Graciano, Charmery .
SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2014, 90 (02) :143-161
[10]   Air-source heat pump carbon footprints: HFC impacts and comparison to other heat sources [J].
Johnson, Eric P. .