Midterm outcome of fourth-generation ceramic-on-ceramic bearing surface in revision total hip arthroplasty

被引:6
作者
Chang, Jun-Dong [1 ]
Kim, In-Sung [1 ]
Mansukhani, Sameer Ajit [1 ]
Sharma, Vishwas [1 ]
Lee, Sang-Soo [2 ]
Yoo, Je-Hyun [3 ]
机构
[1] Hallym Univ, Dept Orthopaed Surg, Dongtan Sacred Heart Hosp, 7,Keunjaebong Gil, Hwaseong Si 445907, Gyeonggi Do, South Korea
[2] Hallym Univ, Coll Med, Chuncheon Sacred Heart Hosp, Dept Orthopaed Surg, Chunchon, South Korea
[3] Hallym Univ, Coll Med, Sacred Heart Hosp, Dept Orthopaed Surg, Anyang, Gyeonggi Do, South Korea
关键词
bearing surface; ceramic-on-ceramic; fourth generation; revision; total hip arthroplasty; PERIPROSTHETIC JOINT INFECTION; POLYETHYLENE BEARINGS; MILLION CYCLES; SQUEAKING; COMPLICATIONS; EPIDEMIOLOGY; DISLOCATION; FRACTURES; MECHANISM; LINER;
D O I
10.1177/2309499018783913
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study is to evaluate the clinical and radiologic outcomes after revision total hip arthroplasty (THA) using fourth-generation ceramic-on-ceramic (CoC) bearing surfaces. Methods: A total of 52 revision THAs (28 men and 19 women) using the fourth-gene ration CoC bearing surfaces were retrospectively evaluated. Both acetabular cup and femoral stem were revised in all cases. The mean follow-up period was 7.3 years (range, 4.0-9.9 years). The clinical results with Harris hip score (HHS), Western Ontario McMaster Osteoarthritis Index (WOMAC), and radiologic outcomes were evaluated. Results: At the final follow-up examination, the average HHS was 90.4 (range, 67-100). The average WOMAC pain and physical function score were 2.8 (range, 0-12) and 16.4 (range, 0-42), respectively. Complications were observed in 10 hips (19.2%). However, there were no bearing surface-related complications, and no cases of dislocation and squeaking. Retroacetabular pelvic osteolysis without cup loosening was observed in one hip at the final follow-up. However, no hip showed radiographic signs of cup loosening, vertical or horizontal acetabular cup migrations, and changes of inclinations during the follow-up period. Conclusion: Our data showed that clinical and radiologic outcomes after revision THA using fourth-generation CoC bearing were favorable. Hence, revision THA with the use of CoC bearing surfaces can be preferentially considered. Further studies with long-term follow-up data are warranted.
引用
收藏
页数:7
相关论文
共 40 条
  • [11] No Significant Squeaking in Total Hip Arthroplasty A Series of 413 Hips in the Asian People
    Chen, Wei-Ming
    Wu, Po-Kuei
    Chen, Cheng-Fong
    Huang, Ching-Kuei
    Liu, Chien-Lin
    Chen, Tain-Hsiung
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (08) : 1575 - 1579
  • [12] Periprosthetic Tissues From Third Generation Alumina-on-Alumina Total Hip Arthroplasties
    Esposito, Christina
    Maclean, Fiona
    Campbell, Pat
    Walter, William L.
    Walter, William K.
    Bonar, S. Fiona
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (05) : 860 - 866
  • [13] Current Epidemiology of Revision Total Hip Arthroplasty in the United States: National Inpatient Sample 2009 to 2013
    Gwam, Chukwuweike U.
    Mistry, Jaydev B.
    Mohamed, Nequesha S.
    Thomas, Melbin
    Bigart, Kevin C.
    Mont, Michael A.
    Delanois, Ronald E.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (07) : 2088 - 2092
  • [14] Strength and reliability of alumina ceramic femoral heads: Review of design, testing, and retrieval analysis
    Huet, Roland
    Sakona, Ashlyn
    Kurtz, Steven M.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (03) : 476 - 483
  • [15] Iamthanaporn Khanin, 2015, Journal of the Medical Association of Thailand, V98, P93
  • [16] JA Browne, 2011, J ARTHROPLASTY, V26, pe5
  • [17] The use of ceramic-on-ceramic bearings in isolated revision of the acetabular component
    Jack, C. M.
    Molloy, D. O.
    Walter, W. L.
    Zicat, B. A.
    Walter, W. K.
    [J]. BONE & JOINT JOURNAL, 2013, 95B (03) : 333 - 338
  • [18] Jacobs JJ, 2001, CLIN ORTHOP RELAT R, P71
  • [19] Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis
    Jolles, BM
    Zangger, P
    Leyvraz, PF
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (03) : 282 - 288
  • [20] Kuntz M., 2006, Semin Arthroplasty, V17, P141