Raman Spectroscopy-A Novel Method for Identification and Characterization of Microbes on a Single-Cell Level in Clinical Settings

被引:31
作者
Rebrosova, Katarina [1 ,2 ]
Samek, Ota [3 ]
Kizovsky, Martin [3 ]
Bernatova, Silvie [3 ]
Hola, Veronika [1 ,2 ]
Ruzicka, Filip [1 ,2 ]
机构
[1] Masaryk Univ, Dept Microbiol, Fac Med, Brno, Czech Republic
[2] St Annes Univ Hosp, Brno, Czech Republic
[3] Czech Acad Sci, Inst Sci Instruments, Brno, Czech Republic
关键词
Raman spectroscopy; Raman tweezers; identification of microorganisms; antimicrobial resistance; microfluidic devices; magnetic beads; diagnostics; POSITIVE BLOOD CULTURES; FIELD-FLOW FRACTIONATION; CANDIDA-PARAPSILOSIS; ESCHERICHIA-COLI; STAPHYLOCOCCUS-EPIDERMIDIS; RAPID IDENTIFICATION; CHEMICAL-COMPOSITION; MASS-SPECTROMETRY; BACTERIAL; PATHOGENS;
D O I
10.3389/fcimb.2022.866463
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Rapid and accurate identification of pathogens causing infections is one of the biggest challenges in medicine. Timely identification of causative agents and their antimicrobial resistance profile can significantly improve the management of infection, lower costs for healthcare, mitigate ever-growing antimicrobial resistance and in many cases, save lives. Raman spectroscopy was shown to be a useful-quick, non-invasive, and non-destructive -tool for identifying microbes from solid and liquid media. Modifications of Raman spectroscopy and/or pretreatment of samples allow single-cell analyses and identification of microbes from various samples. It was shown that those non-culture-based approaches could also detect antimicrobial resistance. Moreover, recent studies suggest that a combination of Raman spectroscopy with optical tweezers has the potential to identify microbes directly from human body fluids. This review aims to summarize recent advances in non-culture-based approaches of identification of microbes and their virulence factors, including antimicrobial resistance, using methods based on Raman spectroscopy in the context of possible use in the future point-of-care diagnostic process.
引用
收藏
页数:10
相关论文
共 146 条
[21]   Microfluidic dielectrophoresis device for trapping, counting and detecting Shewanella oneidensis at the cell level [J].
Chen, Xiangyu ;
Liang, Zhiting ;
Li, Daobo ;
Xiong, Ying ;
Xiong, Penghui ;
Guan, Yong ;
Hou, Shuangyue ;
Hu, Yue ;
Chen, Shan ;
Liu, Gang ;
Tian, Yangchao .
BIOSENSORS & BIOELECTRONICS, 2018, 99 :416-423
[22]   Surface enhanced Raman spectroscopy of Chlamydia trachomatis and Neisseria gonorrhoeae for diagnostics, and extra-cellular metabolomics and biochemical monitoring [J].
Chen, Y. ;
Premasiri, W. R. ;
Ziegler, L. D. .
SCIENTIFIC REPORTS, 2018, 8
[23]   Rapid identification of bacteria utilizing amplified dielectrophoretic force-assisted nanoparticle-induced surface-enhanced Raman spectroscopy [J].
Cheng, I-Fang ;
Chen, Tzu-Ying ;
Lu, Rong-Ji ;
Wu, Hung-Wei .
NANOSCALE RESEARCH LETTERS, 2014, 9 :1-8
[24]   Investigating microbial (micro)colony heterogeneity by vibrational spectroscopy [J].
Choo-Smith, LP ;
Maquelin, K ;
van Vreeswijk, T ;
Bruining, HA ;
Puppels, GJ ;
Thi, NAG ;
Kirschner, C ;
Naumann, D ;
Ami, D ;
Villa, AM ;
Orsini, F ;
Doglia, SM ;
Lamfarraj, H ;
Sockalingum, GD ;
Manfait, M ;
Allouch, P ;
Endtz, HP .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2001, 67 (04) :1461-1469
[25]   Raman biosensor and molecular tools for integrated monitoring of pathogens and antimicrobial resistance in wastewater [J].
Cui, Li ;
Li, Hong-Zhe ;
Yang, Kai ;
Zhu, Long-Ji ;
Xu, Fei ;
Zhu, Yong-Guan .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 143 (143)
[26]   Raman spectroscopy: Recent advancements, techniques and applications [J].
Das, Ruchita S. ;
Agrawal, Y. K. .
VIBRATIONAL SPECTROSCOPY, 2011, 57 (02) :163-176
[27]   Biochemical characterization of pathogenic bacterial species using Raman spectroscopy and discrimination model based on selected spectral features [J].
de Siqueira e Oliveira, Fernanda SantAna ;
da Silva, Adriano Moraes ;
Tavares Pacheco, Marcos Tadeu ;
Giana, Hector Enrique ;
Silveira Jr, Landulfo .
LASERS IN MEDICAL SCIENCE, 2021, 36 (02) :289-302
[28]   Antimicrobial susceptibility testing of Gram-positive and -negative bacterial isolates directly from spiked blood culture media with Raman spectroscopy [J].
Dekter, H. E. ;
Orelio, C. C. ;
Morsink, M. C. ;
Tektas, S. ;
Vis, B. ;
te Witt, R. ;
van Leeuwen, W. B. .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2017, 36 (01) :81-89
[29]   Quartz microfluidic chip for tumour cell identification by Raman spectroscopy in combination with optical traps [J].
Dochow, Sebastian ;
Beleites, Claudia ;
Henkel, Thomas ;
Mayer, Guenter ;
Albert, Jens ;
Clement, Joachim ;
Krafft, Christoph ;
Popp, Juergen .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (08) :2743-2746
[30]   Detection of microorganisms in blood specimens using matrix-assisted laser desorption ionization time-of-flight mass spectrometry: a review [J].
Drancourt, M. .
CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (11) :1620-1625