Minimally invasive reduction of thoracolumbar burst fracture using monoaxial percutaneous pedicle screws: Surgical technique and report of radiological outcome

被引:12
作者
Chung, Weng Hong [1 ]
Eu, Wei Cheong [1 ]
Chiu, Chee Kidd [1 ]
Chan, Chris Yin Wei [1 ]
Kwan, Mun Keong [1 ]
机构
[1] Univ Malaya, Fac Med, Dept Orthopaed Surg, NOCERAL, Kuala Lumpur 50603, Malaysia
关键词
burst fracture; fracture reduction; minimally invasive spine surgery; monoaxial pedicle screw; thoracolumbar; POSTERIOR LIGAMENTOUS COMPLEX; SPINE SURGERY; LUMBAR SPINE; FIXATION; ANTERIOR; INJURY; CLASSIFICATION; MANAGEMENT; PLACEMENT; SAFETY;
D O I
10.1177/2309499019888977
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To describe the reduction technique of thoracolumbar burst fracture using percutaneous monoaxial screws and its radiological outcomes compared to polyaxial screws. Methods: All surgeries were performed by minimally invasive technique with either percutaneous monoaxial or percutaneous polyaxial screws inserted at adjacent fracture levels perpendicular to both superior end plates. Fracture reduction is achieved with adequate rod contouring and distraction maneuver. Radiological parameters were measured during preoperation, postoperation, and follow-up. Results: A total of 21 patients were included. Eleven patients were performed with monoaxial pedicle screws and 10 patients performed with polyaxial pedicle screws. Based on AO thoracolumbar classification system, 10 patients in the monoaxial group had A3 fracture type and 1 had A4. In the polyaxial group, six patients had A3 and four patients had A4. Total correction of anterior vertebral height (AVH) ratio was 0.30 +/- 0.10 and 0.08 +/- 0.07 in monoaxial and polyaxial groups, respectively (p < 0.001). Total correction of posterior vertebral height (PVH) ratio was 0.11 +/- 0.05 and 0.02 +/- 0.02 in monoaxial and polyaxial groups, respectively (p < 0.001). Monoaxial group achieved more correction of 13 degrees (62.6%) in local kyphotic angle compared to 8.2 degrees (48.0%) in polyaxial group. Similarly, in regional kyphotic angle, 16.5 degrees (103.1%) in the monoaxial group and 8.1 degrees (76.4%) in the polyaxial group were achieved. Conclusions: Monoaxial percutaneous pedicle screws inserted at adjacent fracture levels provided significantly better fracture reduction compared to polyaxial screws in thoracolumbar fractures.
引用
收藏
页数:9
相关论文
共 30 条
[1]   Anterior spine surgery in recent thoracolumbar fractures: An update [J].
Allain, J. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (05) :541-554
[2]   Percutaneous management of thoracolumbar burst fractures: Evolution of techniques and strategy [J].
Blondel, B. ;
Fuentes, S. ;
Pech-Gourg, G. ;
Adetchessi, T. ;
Tropiano, P. ;
Dufour, H. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (05) :527-532
[3]   The accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine A REVIEW OF 880 SCREWS [J].
Chiu, C. K. ;
Kwan, M. K. ;
Chan, C. Y. W. ;
Schaefer, C. ;
Hansen-Algenstaedt, N. .
BONE & JOINT JOURNAL, 2015, 97B (08) :1111-1117
[4]   Percutaneous pedicle screw fixation of the lumbar spine: preliminary clinical results [J].
Foley, KT ;
Gupta, SK .
JOURNAL OF NEUROSURGERY, 2002, 97 (01) :7-12
[5]  
Ghanayem AJ, 1997, CLIN ORTHOP RELAT R, P89
[6]   ANTERIOR PLATING IN THORACOLUMBAR SPINE INJURIES - INDICATION, TECHNIQUE, AND RESULTS [J].
HAAS, N ;
BLAUTH, M ;
TSCHERNE, H .
SPINE, 1991, 16 (03) :S100-S111
[7]   Accuracy and Safety of Fluoroscopic Guided Percutaneous Pedicle Screws in Thoracic and Lumbosacral Spine [J].
Hansen-Algenstaedt, Nils ;
Chiu, Chee Kidd ;
Chan, Chris Yin Wei ;
Lee, Chee Kean ;
Schaefer, Christian ;
Kwan, Mun Keong .
SPINE, 2015, 40 (17) :E954-E963
[8]  
Heary Robert F, 2007, Indian J Orthop, V41, P268, DOI 10.4103/0019-5413.36986
[9]   Comparison of a Paraspinal Approach with a Percutaneous Approach in the Treatment of Thoracolumbar Burst Fractures with Posterior Ligamentous Complex Injury: a Prospective Randomized Controlled Trial [J].
Jiang, X. Z. ;
Tian, W. ;
Liu, B. ;
Li, Q. ;
Zhang, G. L. ;
Hu, L. ;
Li, Z. Y. ;
He, D. .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2012, 40 (04) :1343-1356
[10]   Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits [J].
Kaneda, K ;
Taneichi, H ;
Abumi, K ;
Hashimoto, T ;
Satoh, S ;
Fujiya, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (01) :69-83