Load-frequency control in a multi-source power system connected to wind farms through multi terminal HVDC systems

被引:42
作者
Tavakoli, Mehdi [1 ]
Pouresmaeil, Edris [2 ,3 ]
Adabi, Jafar [4 ]
Godina, Radu [5 ]
Catalao, Joao P. S. [3 ,5 ,6 ,7 ]
机构
[1] Mazandaran Univ Sci & Technol, Dept Elect Engn, Babol Sar, Mazandaran, Iran
[2] Aalto Univ, Dept Elect Engn & Automat, Espoo 02150, Finland
[3] Univ Lisbon, Inst Super Tecn, INESC ID, P-1049001 Lisbon, Portugal
[4] Babol Noshirvani Univ Technol, Fac Elect & Comp Engn, POB 484, Babol Sar, Iran
[5] Univ Beira Interior, C MAST, P-6201001 Covilha, Portugal
[6] Univ Porto, INESC TEC, P-4200465 Porto, Portugal
[7] Univ Porto, Fac Engn, P-4200465 Porto, Portugal
关键词
Frequency control; Particle swarm optimization (PSO); Wind farm; Multi-terminal HVDC; AUTOMATIC-GENERATION CONTROL; DIFFERENTIAL EVOLUTION ALGORITHM; TRANSMISSION; PARAMETERS; DESIGN;
D O I
10.1016/j.cor.2018.03.002
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper addresses the wind farm contribution in frequency control during the integration in the power grid. In the proposed model, the wind farm utilizes inertia control and droop control techniques with the purpose of improving the frequency regulation. In order to achieve optimal results, all the parameters of the controllers for the different units in the power grid are obtained by using a particle swarm optimization algorithm (PSO) and by introducing a modified objective function instead of a conventional objective function e.g., Integral Time-weighted Absolute Error (ITAE). Also, different constraints such as reheat turbine, time delay, governor dead band and generation rate constraint (GRC) are considered for thermal and hydro units with the aim of studying a more realistic power system, which is the main contribution of this paper when compared to the other works in this field. It is shown that, in case of a perturbation in power demand, the system frequency will recover quickly and effectively in comparison with the traditional approaches. In addition, a sensitivity test is carried out in a single power grid area in order to examine the effectiveness of the proposed approach. Then, the system is extended to a multi-area power system using a multi-terminal HVDC for further investigation of the suggested strategy. Simulation results are presented in order to assess the performance of the proposed approach in the power system. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:305 / 315
页数:11
相关论文
共 50 条
  • [21] Load frequency control of a two-area multi-source power system using a tilt integral derivative controller
    Topno, Pretty Neelam
    Chanana, Saurabh
    JOURNAL OF VIBRATION AND CONTROL, 2018, 24 (01) : 110 - 125
  • [22] Impacts of wind farms with multi-terminal HVDC system in frequency regulation using quasi-opposition pathfinder algorithm
    Saxena, Abhishek
    Shiva, Chandan Kumar
    Shankar, Ravi
    Vedik, B.
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2021, 12 (06) : 1434 - 1446
  • [23] Primary Frequency Control of Remote Grids Connected by Multi-terminal HVDC
    Haileselassie, Temesgen M.
    Uhlen, Kjetil
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [24] Proposal and Verification of Frequency Control Method for Multi-Terminal HVDC Systems
    Nakamura A.
    Hara R.
    Kita H.
    IEEJ Transactions on Power and Energy, 2024, 144 (06) : 356 - 363
  • [25] Control of multi-terminal HVDC networks towards wind power integration: A review
    Bianchi, Fernando D.
    Luis Dominguez-Garcia, Jose
    Gomis-Bellmunt, Oriol
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 55 : 1055 - 1068
  • [26] A multi-terminal HVDC transmission system for offshore wind farms with induction generators
    Liang, Jun
    Gomis-Bellmunt, Oriol
    Ekanayake, Janaka
    Jenkins, Nicholas
    An, Wen
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 43 (01) : 54 - 62
  • [27] Droop control for loss minimization in HVDC multi-terminal transmission systems for large offshore wind farms
    Araguees-Penalba, Monica
    Egea-Alvarez, Agusti
    Galceran Arellano, Samuel
    Gomis-Bellmunt, Oriol
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 112 : 48 - 55
  • [28] Terminal Voltage and Load Frequency Control in a Real Four-Area Multi-Source Interconnected Power System With Nonlinearities via OOBO Algorithm
    Ali, Tayyab
    Asad, Muhammad
    Touti, Ezzeddine
    Graba, Besma Bechir
    Aoudia, Mouloud
    Abbas, Ghulam
    Alnuman, Hammad
    Nureldeen, Waleed
    IEEE ACCESS, 2024, 12 : 123782 - 123803
  • [29] Sliding mode based load-frequency control in power systems
    Vrdoljak, K.
    Peric, N.
    Petrovic, I.
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (05) : 514 - 527
  • [30] A Novel Improved GSA-BPSO Driven PID Controller for Load Frequency Control of Multi-Source Deregulated Power System
    Kumar, Ajay
    Gupta, Deepak Kumar
    Ghatak, Sriparna Roy
    Appasani, Bhargav
    Bizon, Nicu
    Thounthong, Phatiphat
    MATHEMATICS, 2022, 10 (18)