Load-frequency control in a multi-source power system connected to wind farms through multi terminal HVDC systems

被引:42
|
作者
Tavakoli, Mehdi [1 ]
Pouresmaeil, Edris [2 ,3 ]
Adabi, Jafar [4 ]
Godina, Radu [5 ]
Catalao, Joao P. S. [3 ,5 ,6 ,7 ]
机构
[1] Mazandaran Univ Sci & Technol, Dept Elect Engn, Babol Sar, Mazandaran, Iran
[2] Aalto Univ, Dept Elect Engn & Automat, Espoo 02150, Finland
[3] Univ Lisbon, Inst Super Tecn, INESC ID, P-1049001 Lisbon, Portugal
[4] Babol Noshirvani Univ Technol, Fac Elect & Comp Engn, POB 484, Babol Sar, Iran
[5] Univ Beira Interior, C MAST, P-6201001 Covilha, Portugal
[6] Univ Porto, INESC TEC, P-4200465 Porto, Portugal
[7] Univ Porto, Fac Engn, P-4200465 Porto, Portugal
关键词
Frequency control; Particle swarm optimization (PSO); Wind farm; Multi-terminal HVDC; AUTOMATIC-GENERATION CONTROL; DIFFERENTIAL EVOLUTION ALGORITHM; TRANSMISSION; PARAMETERS; DESIGN;
D O I
10.1016/j.cor.2018.03.002
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper addresses the wind farm contribution in frequency control during the integration in the power grid. In the proposed model, the wind farm utilizes inertia control and droop control techniques with the purpose of improving the frequency regulation. In order to achieve optimal results, all the parameters of the controllers for the different units in the power grid are obtained by using a particle swarm optimization algorithm (PSO) and by introducing a modified objective function instead of a conventional objective function e.g., Integral Time-weighted Absolute Error (ITAE). Also, different constraints such as reheat turbine, time delay, governor dead band and generation rate constraint (GRC) are considered for thermal and hydro units with the aim of studying a more realistic power system, which is the main contribution of this paper when compared to the other works in this field. It is shown that, in case of a perturbation in power demand, the system frequency will recover quickly and effectively in comparison with the traditional approaches. In addition, a sensitivity test is carried out in a single power grid area in order to examine the effectiveness of the proposed approach. Then, the system is extended to a multi-area power system using a multi-terminal HVDC for further investigation of the suggested strategy. Simulation results are presented in order to assess the performance of the proposed approach in the power system. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:305 / 315
页数:11
相关论文
共 50 条
  • [1] Analysis of PID controller for the load frequency control of static synchronous series compensator and capacitive energy storage source-based multi-area multi-source interconnected power system with HVDC link
    Khadanga, Rajendra Kumar
    Kumar, Amit
    INTERNATIONAL JOURNAL OF BIO-INSPIRED COMPUTATION, 2019, 13 (02) : 131 - 139
  • [2] Load Frequency Control Using Hybrid Intelligent Optimization Technique for Multi-Source Power Systems
    Gupta, Deepak Kumar
    Jha, Amitkumar V.
    Appasani, Bhargav
    Srinivasulu, Avireni
    Bizon, Nicu
    Thounthong, Phatiphat
    ENERGIES, 2021, 14 (06)
  • [3] Optimal Operation of Multi terminal HVDC Links Connected to Offshore Wind Farms
    Yazdi, Seyyed Saeed Heidary
    Fathi, Seyyed Hamid
    Monfared, Jafar Mili
    Amiri, Erfan Maali
    2014 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2014,
  • [4] PEV assisted Primary Frequency Control of a Wind Integrated Multi-Source Power System
    Sarma, Praveen S.
    Chandran, Sunil V.
    Jose, Athul P.
    Deepak, M.
    2022 IEEE INTERNATIONAL POWER AND RENEWABLE ENERGY CONFERENCE, IPRECON, 2022,
  • [5] Coordinated control of multi-terminal HVDC transmission system for offshore wind farms
    State Key Laboratory of Alternate Electrical Power System With Renewable Energy Sources, North China Electric Power University, Baoding 071003, Hebei Province, China
    Dianwang Jishu, 1 (8-15): : 8 - 15
  • [6] Load Frequency Control Assessment of a PSO-PID Controller for a Standalone Multi-Source Power System
    Dhanasekaran, Boopathi
    Kaliannan, Jagatheesan
    Baskaran, Anand
    Dey, Nilanjan
    Tavares, Joao Manuel R. S.
    TECHNOLOGIES, 2023, 11 (01)
  • [7] Offshore Wind Farms Integration and Frequency Support Control Utilizing Hybrid Multi-terminal HVDC Transmission
    Li, Cheng-hao
    Zhan, Peng
    Wen, Jin-yu
    Yao, Mei-qi
    Li, Nai-hu
    Lee, Wei-jen
    2013 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2013,
  • [8] Discrete-Time Optimal Controller for Load Frequency Control of Multi-Source Power System in Egypt
    Magdy, G.
    Bakeer, Abualkasim
    Shabib, G.
    Elbaset, Adel A.
    Mitani, Yasunori
    PROCEEDINGS OF 2018 INTERNATIONAL CONFERENCE ON INNOVATIVE TRENDS IN COMPUTER ENGINEERING (ITCE' 2018), 2018, : 264 - 270
  • [9] Optimal Designing of Fuzzy-PID Controller in the Load-Frequency Control Loop of Hydro-Thermal Power System Connected to Wind Farm by HVDC Lines
    Kamarposhti, Mehrdad Ahmadi
    Shokouhandeh, Hassan
    Alipur, Meghdad
    Colak, Ilhami
    Zare, Hassan
    Eguchi, Kei
    IEEE ACCESS, 2022, 10 : 63812 - 63822
  • [10] DC voltage control and power dispatch of a multi-terminal HVDC system for integrating large offshore wind farms
    Xu, L.
    Yao, L.
    IET RENEWABLE POWER GENERATION, 2011, 5 (03) : 223 - 233