Experiments with a 'psychrometric' roof pond system for passive cooling in hot-arid regions

被引:23
作者
Pearlmutter, David [1 ]
Berliner, Pedro [1 ]
机构
[1] Ben Gurion Univ Negev, Jacob Blaustein Inst Desert Res, Beer Sheva, Israel
关键词
Passive cooling; Evaporation; Psychrometric roof pond; THERMAL PERFORMANCE; WATER; EVAPORATION; SIMULATION; CLIMATE; DESIGN; SOIL;
D O I
10.1016/j.enbuild.2017.03.067
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Roof pond systems for passive cooling of buildings are often limited in their efficiency because of solar heating loads or insufficient ventilation. Here we test the performance of a roof cooling configuration that resembles a naturally-ventilated psychrometer - designed to maintain a temperature close to that of the ambient wet-bulb by employing an elevated shading structure which allows for a free flow of air and maximizes evaporation. Comparing the performance of this 'psychrometric' roof pond (PRP) with a control roof under hot-dry conditions, it was found that the internal surface temperature of the PRP was up to 15 degrees C lower and that cooling was equally effective whether the roof pond was fully or partially exposed to the night sky. Throughout the hours of a summer day, air temperature in the cell was maintained within accepted comfort limits while the reference cell was continuously overheated. An analysis of energy fluxes above the roof showed that both the modified radiation balance and the conversion of sensible to latent heat through evaporation were significant contributors to the dramatically reduced heat gain and cooling effectiveness. Due to its low water requirement and simplicity, the tested configuration could have a significant potential for resource-efficient cooling. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:295 / 302
页数:8
相关论文
共 27 条
[1]   IMPROVING THE THERMAL PERFORMANCE OF A ROOF POND SYSTEM [J].
AHMAD, I .
ENERGY CONVERSION AND MANAGEMENT, 1985, 25 (02) :207-209
[2]   Passive cooling of water at night in uninsulated open tank in hot and areas [J].
Ali, Ahmed Hamza H. .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (01) :93-100
[3]   DESIGN OPTIMIZATION OF PASSIVELY COOLED ROOM [J].
CHU, SCK ;
BOONLONG, P .
JOURNAL OF ENERGY ENGINEERING-ASCE, 1992, 118 (01) :18-37
[4]   Evaluating the potential of an indirect evaporative passive cooling system for Brazilian dwellings [J].
Cruz, Eduardo Gonzalez ;
Krueger, Eduardo .
BUILDING AND ENVIRONMENT, 2015, 87 :265-273
[5]   Reducing cooling demands in a hot dry climate: A simulation study for non-insulated passive cool roof thermal performance in residential buildings [J].
Dabaieh, Marwa ;
Wanas, Omar ;
Hegazy, Mohamed Amer ;
Johansson, Erik .
ENERGY AND BUILDINGS, 2015, 89 :142-152
[6]   Analysis and experimental verification of an improved cooling radiator [J].
Erell, E ;
Etzion, Y .
RENEWABLE ENERGY, 1999, 16 (1-4) :700-703
[7]   Indoor temperature reduction by passive cooling systems [J].
Givoni, Baruch .
SOLAR ENERGY, 2011, 85 (08) :1692-1726
[8]   Modeling of solar passive techniques for roof cooling in arid regions [J].
Jain, D .
BUILDING AND ENVIRONMENT, 2006, 41 (03) :277-287
[9]   Integrated modeling of pedestrian energy exchange and thermal comfort in urban street canyons [J].
Pearlmutter, D. ;
Berliner, P. ;
Shaviv, E. .
BUILDING AND ENVIRONMENT, 2007, 42 (06) :2396-2409
[10]   The role of evaporation in the energy balance of an open-air scaled urban surface [J].
Pearlmutter, D. ;
Krueger, E. L. ;
Berliner, P. .
INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2009, 29 (06) :911-920