Gel permeation chromatography followed by pyrolysis-gas chromatography-mass spectrometry via a solvent-evaporative interface

被引:10
作者
Zhu, WW [1 ]
Allaway, JR [1 ]
机构
[1] Johnson Polymer, Sturtevant, WI 53177 USA
关键词
gel permeation chromatography; pyrolysis; LC-transform; polymer composition; chemical heterogeneity versus molecular weight;
D O I
10.1016/j.chroma.2004.08.148
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of chemical composition as a function of molecular weight has always been a challenge for analytical chemists. In this paper. we present a unique way to combine gel permeation chromatography (GPC) with pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) for this purpose. A commercially available solvent-evaporative interface, originally designed for GPC-IR measurements, was used to deposit the eluent of GPC onto aluminum foil. Small strips of aluminum foil were cut and subjected to Py-GC-MS analysis. Compared with the GPC-IR measurements, the proposed technique offers the advantage of being able to distinguish between structurally similar monomers in a complex copolymer. As an example, a copolymer composed of four monomers was analyzed. The results clearly demonstrate that this technique can be applied to complex polymeric systems to yield information regarding chemical heterogeneity versus molecular weight. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 19 条
[1]  
[Anonymous], APPL PYROLYSIS HDB
[2]  
Brandrup J., 1999, POLYM HDB, P203
[3]   FOURIER-TRANSFORM INFRARED SPECTROMETRIC DETECTION IN SIZE-EXCLUSION CHROMATOGRAPHIC-SEPARATION OF POLAR SYNFUEL MATERIAL [J].
BROWN, RS ;
HAUSLER, DW ;
TAYLOR, LT ;
CARTER, RC .
ANALYTICAL CHEMISTRY, 1981, 53 (02) :197-201
[4]   CONTINUOUS INFRARED SPECTROSCOPIC ANALYSIS OF ISOCRATIC AND GRADIENT ELUTION REVERSED-PHASE LIQUID-CHROMATOGRAPHY SEPARATIONS [J].
GAGEL, JJ ;
BIEMANN, K .
ANALYTICAL CHEMISTRY, 1987, 59 (09) :1266-1272
[5]   CONTINUOUS RECORDING OF REFLECTION ABSORBENCY FOURIER-TRANSFORM INFRARED-SPECTRA OF THE EFFLUENT OF A MICROBORE LIQUID CHROMATOGRAPH [J].
GAGEL, JJ ;
BIEMANN, K .
ANALYTICAL CHEMISTRY, 1986, 58 (11) :2184-2189
[6]   Pyrolysis gas chromatography mass spectrometry investigation of a thermally cured polymer [J].
Galipo, RC ;
Egan, WJ ;
Aust, JF ;
Myrick, ML ;
Morgan, SL .
JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 1998, 45 (01) :23-40
[7]   OPTIMIZATION OF A FLOW CELL INTERFACE FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY [J].
HELLGETH, JW ;
TAYLOR, LT .
ANALYTICAL CHEMISTRY, 1987, 59 (02) :295-300
[8]   ZERO DEAD VOLUME FLOW CELL FOR MICROBORE LIQUID-CHROMATOGRAPHY WITH FOURIER-TRANSFORM INFRARED SPECTROMETRIC DETECTION [J].
JOHNSON, CC ;
TAYLOR, LT .
ANALYTICAL CHEMISTRY, 1984, 56 (14) :2642-2647
[9]   Forensic discrimination of automotive paint samples using pyrolysis-gas chromatography-mass spectrometry with multivariate statistics [J].
Kochanowski, BK ;
Morgan, SL .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2000, 38 (03) :100-108
[10]   Comparison of on-line flow-cell and off-line solvent-elimination interfaces for size-exclusion chromatography and Fourier-transform infrared spectroscopy in polymer analysis [J].
Kok, SJ ;
Wold, CA ;
Hankemeier, T ;
Schoenmakers, PJ .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1017 (1-2) :83-96