Investigation of the effect of anode/filter materials on the dose and image quality of a digital mammography system based on an amorphous selenium flat panel detector

被引:41
作者
Baldelli, P. [1 ]
Phelan, N. [1 ]
Egan, G. [1 ]
机构
[1] Natl Canc Screening Serv, Dublin, Ireland
关键词
SPECTRAL SHAPE; OPTIMIZATION; MODEL;
D O I
10.1259/bjr/60404532
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A comparison, in terms of image quality and glandular breast dose, was carried out between two similar digital mammography systems using amorphous selenium flat panel detectors. The two digital mammography systems currently available from Lorad-Hologic were compared. The original system utilises Mo/Mo and Mo/Rh as target/filter combinations, while the new system uses W/Rh and W/Ag. Images of multiple mammography phantoms with simulated compressed breast thicknesses of 4 cm, 5 cm and 6 cm and various glandular tissue equivalency were acquired under different spectral conditions. The contrast of five details, corresponding to five glandular compositions, was calculated and the ratio of the square of the contrast-to-noise ratio to the average glandular dose was used as a figure-of-merit (FOM) to compare results. For each phantom thickness and target/filter combination, there is an optimum voltage that maximises the FOM. Results show that the W/Rh combination is the best choice for all the detection tasks studied, but for thicknesses greater than 6 cm the W/Ag combination would probably be the best choice. In addition, the new system with W filter presents a better optimisation of the automatic exposure control in comparison with the original system with Mo filter.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 12 条
[1]   Optimization of tungsten x-ray spectra for digital mammography: Comparison of model to experiment [J].
Andre, MP ;
Spivey, BA .
PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 :411-418
[2]  
[Anonymous], 2006, EUR GUID QUAL ASS BR
[3]   X-ray spectrum optimization of full-field digital mammography: Simulation and phantom study [J].
Bernhardt, Philipp ;
Mertelmeier, Thomas ;
Hoheisel, Martin .
MEDICAL PHYSICS, 2006, 33 (11) :4337-4349
[4]   Influence of anode/filter material and tube potential on contrast, signal-to-noise ratio and average absorbed dose in mammography: a Monte Carlo study [J].
Dance, DR ;
Klang, AT ;
Sandborg, M ;
Skinner, CL ;
Smith, IAC ;
Carlsson, GA .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (874) :1056-1067
[5]   Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol [J].
Dance, DR ;
Skinner, CL ;
Young, KC ;
Beckett, JR ;
Kotre, CJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (11) :3225-3240
[6]   A MODEL FOR OPTIMIZATION OF SPECTRAL SHAPE IN DIGITAL MAMMOGRAPHY [J].
FAHRIG, R ;
YAFFE, MJ .
MEDICAL PHYSICS, 1994, 21 (09) :1463-1471
[7]   OPTIMIZATION OF SPECTRAL SHAPE IN DIGITAL MAMMOGRAPHY - DEPENDENCE ON ANODE MATERIAL, BREAST THICKNESS, AND LESION TYPE [J].
FAHRIG, R ;
YAFFE, MJ .
MEDICAL PHYSICS, 1994, 21 (09) :1473-1481
[8]   Optimal radiographic techniques for digital mammograms obtained with an amorphous selenium detector [J].
Flynn, M ;
Dodge, C ;
Peck, D ;
Swinford, A .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :147-156
[9]  
JENNINGS RJ, 1993, P SOC PHOTO-OPT INS, V1896, P259, DOI 10.1117/12.154597
[10]  
LO JY, 2004, P IWDM, P31