Cobalt oxide/tetraruthenated cobalt-porphyrin composite for hydrogen peroxide amperometric sensors

被引:62
作者
Quintino, MSM [1 ]
Winnischofer, H [1 ]
Araki, K [1 ]
Toma, HE [1 ]
Angnes, L [1 ]
机构
[1] Univ Sao Paulo, Inst Quim, Dept Quim Fundamental, BR-05508900 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
D O I
10.1039/b415496g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new composite material constituted by mu-{5,10,15,20- tetra(4-pyridyl) porphyrinato cobalt(III)}tetrakis-{ chloro-bis-(2,2'-bipyridine) ruthenium(II)} complex ( or CoTRP) and cobalt oxide, exhibiting high stability and sensitivity for the quantification of hydrogen peroxide, was obtained by the electrochemical polymerization of the tetraruthenated cobalt porphyrin in alkaline medium. The optimized experimental conditions for the preparation of the modified glassy carbon electrodes and for analysis of H2O2 were carefully determined. Fast sequential analysis ( 120 determinations h(-1)) in a wide linear dynamic range ( 5.0 x 10(-7) mol L-1 to 2.0 x 10(-3) mol L-1), with high sensitivity and low detection limit (2.0 x 10(-7) mol L-1), was achieved by using these electrodes and the batch injection analysis (BIA) technique. Such characteristics allied to a good stability were explored for the specific determination of hydrogen peroxide in six commercial cosmetics and pharmaceutical product samples, giving results in excellent agreement with those obtained by the spectrophotometric method.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 44 条
[1]   Electrochemical detection of NADH and dopamine in flow analysis based on tetraruthenated porphyrin modified electrodes [J].
Angnes, L ;
Azevedo, CMN ;
Araki, K ;
Toma, HE .
ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) :91-95
[2]  
[Anonymous], 1974, METHODS ENZYMATIC AN
[3]   ELECTROCHEMISTRY OF A TETRARUTHENATED COBALT PORPHYRIN AND ITS USE IN MODIFIED ELECTRODES AS SENSORS OF REDUCING ANALYTES [J].
ARAKI, K ;
ANGNES, L ;
AZEVEDO, CMN ;
TOMA, HE .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2) :205-210
[4]   Layer-by-layer growth of electrostatically assembled multilayer porphyrin films [J].
Araki, K ;
Wagner, MJ ;
Wrighton, MS .
LANGMUIR, 1996, 12 (22) :5393-5398
[5]   Chemistry of supramolecular systems containing porphyrins and metal complexes [J].
Araki, K ;
Toma, HE .
QUIMICA NOVA, 2002, 25 (6A) :962-975
[6]   Determination of sulfur dioxide in wines by gas-diffusion flow injection analysis utilizing modified electrodes with electrostatically assembled films of tetraruthenated porphyrin [J].
Azevedo, CMN ;
Araki, K ;
Toma, HE ;
Angnes, L .
ANALYTICA CHIMICA ACTA, 1999, 387 (02) :175-180
[7]  
Azevedo CMN, 1998, ELECTROANAL, V10, P467, DOI 10.1002/(SICI)1521-4109(199806)10:7<467::AID-ELAN467>3.0.CO
[8]  
2-W
[9]   Hydrogen peroxide determination in pharmaceutical formulations and cosmetics using a new catalase biosensor [J].
Campanella, L ;
Roversi, R ;
Sammartino, MP ;
Tomassetti, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (1-2) :105-116
[10]   SPECTROPHOTOMETRIC DETERMINATION OF HYDROGEN-PEROXIDE AFTER EXTRACTION WITH ETHYL-ACETATE [J].
CLAPP, PA ;
EVANS, DF ;
SHERIFF, TSS .
ANALYTICA CHIMICA ACTA, 1989, 218 (02) :331-334