Subclinical cardiac perforation by cardiac implantable electronic device leads detected by cardiac computed tomography

被引:6
作者
Lim, Yeong-Min [1 ]
Uhm, Jae-Sun [2 ]
Kim, Min [2 ]
Kim, In-Soo [2 ]
Jin, Moo-Nyun [2 ]
Yu, Hee Tae [2 ]
Kim, Tae-Hoon [2 ]
Lee, Hye-Jeong [3 ]
Kim, Young-Jin [3 ]
Joung, Boyoung [2 ]
Pak, Hui-Nam [2 ]
Lee, Moon-Hyoung [2 ]
机构
[1] St Carollo Hosp, Div Cardiol, Dept Internal Med, Sunchon, Jeollanam Do, South Korea
[2] Yonsei Univ, Yongin Severance Hosp, Dept Cardiol, Coll Med, 363 Dongbaekjukjeondaero Giheung Gu Yongin, Seoul, South Korea
[3] Yonsei Univ, Severance Hosp, Dept Radiol, Coll Med, Seoul, South Korea
关键词
Cardiac computed tomography; Cardiac implantable electronic device; Cardiac perforation; Complications; CONDITIONAL PACING LEAD; OUTFLOW TRACT; PACEMAKER; COMPLICATIONS; MRI; DISLODGMENT; POSITION;
D O I
10.1186/s12872-021-02159-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The relationship between the characteristics of cardiac implantable electronic device (CIED) leads and subclinical cardiac perforations remains unclear. This study aimed to evaluate the incidence of subclinical cardiac perforation among various CIED leads using cardiac computed tomography (CT). Methods A total of 271 consecutive patients with 463 CIED leads, who underwent cardiac CT after CIED implantation, were included in this retrospective observational study. Cardiac CT images were reviewed by one radiologist and two cardiologists. Subclinical perforation was defined as traversal of the lead tip past the outer myocardial layer without symptoms and signs related to cardiac perforation. We compared the subclinical cardiac perforation rates of the available lead types. Results A total of 219, 49, and 3 patients had pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy, respectively. The total subclinical cardiac perforation rate was 5.6%. Subclinical cardiac perforation by screw-in ventricular leads was significantly more frequent than that caused by tined ventricular leads (13.3% vs 3.3%, respectively, p = 0.002). There were no significant differences in the incidence of cardiac perforation between atrial and ventricular leads, screw-in and tined atrial leads, pacing and defibrillator ventricular leads, nor between magnetic resonance (MR)-conditional and MR-unsafe screw-in ventricular leads. Screw-in ventricular leads were significantly associated with subclinical cardiac perforation [odds ratio, 4.554; 95% confidence interval, 1.587-13.065, p = 0.005]. There was no case subclinical cardiac perforation by septal ventricular leads. Conclusions Subclinical cardiac perforation by screw-in ventricular leads is not rare. Septal pacing may be helpful in avoiding cardiac perforation.
引用
收藏
页数:8
相关论文
共 23 条
  • [11] Complications of Cardiac Perforation and Lead Dislodgement with an MRI-Conditional Pacing Lead: A Korean Multi-Center Experience
    Kwon, Chang Hee
    Choi, Jin Hee
    Kim, Jun
    Jo, Uk
    Lee, Ji Hyun
    Lee, Woo Seok
    Kim, Yoo Ri
    Lee, Soo Yong
    Whang, Ki Won
    Yang, Jihyun
    Kim, Sung-Hwan
    Oh, Yong-Seog
    Park, Kyoung-Min
    Nam, Gi-Byoung
    Choi, Kee-Joon
    Kim, You-Ho
    [J]. JOURNAL OF KOREAN MEDICAL SCIENCE, 2016, 31 (09) : 1397 - 1402
  • [12] Liang Jackson J, 2013, Indian Heart J, V65, P331, DOI 10.1016/j.ihj.2013.04.009
  • [13] Impact of Pacemaker Lead Characteristics on Pacemaker Related Infection and Heart Perforation: A Nationwide Population-Based Cohort Study
    Lin, Yu-Sheng
    Chen, Tien-Hsing
    Hung, Sheng-Ping
    Chen, Dong Yi
    Mao, Chun-Tai
    Tsai, Ming-Lung
    Chang, Shih-Tai
    Wang, Chun-Chieh
    Wen, Ming-Shien
    Chen, Mien-Cheng
    [J]. PLOS ONE, 2015, 10 (06):
  • [14] Imaging and Right Ventricular Pacing Lead Position: A Comparison of CT, MRI, and Echocardiography
    Moore, Peter
    Coucher, John
    Ngai, Stanley
    Stanton, Tony
    Wahi, Sudhir
    Gould, Paul
    Booth, Cameron
    Pratap, Jit
    Kaye, Gerald
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (04): : 382 - 392
  • [15] Subacute Right Ventricle Perforation by Pacemaker Lead Presenting with Left Hemothorax and Shock
    Nichols, Julianne
    Berger, Natalie
    Joseph, Praveen
    Datta, Debapriya
    [J]. CASE REPORTS IN CARDIOLOGY, 2015, 2015
  • [16] Delayed cardiac perforation due to migrating pacemaker lead
    Oikonomou, Anastasia
    Foutzitzi, Soultana
    Prassopoulos, Panos
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2010, 182 (09) : E379 - E379
  • [17] Pacing and Implantable Cardioverter Defibrillator Lead Perforation As Assessed by Multiplanar Reformatted ECG-Gated Cardiac Computed Tomography and Clinical Correlates
    Pang, Benjamin J.
    Lui, Elaine H.
    Joshi, Subodh B.
    Tacey, Mark A.
    Alison, Jeff
    Seneviratne, Sujith K.
    Cameron, James D.
    Mond, Harry G.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (05): : 537 - 545
  • [18] Late Perforation by Cardiac Implantable Electronic Device Leads: Clinical Presentation, Diagnostic Clues, and Management
    Refaat, Marwan M.
    Hashash, Jana G.
    Shalaby, Alaa A.
    [J]. CLINICAL CARDIOLOGY, 2010, 33 (08) : 466 - 475
  • [19] Right Ventricular Septal Pacing: A Comparative Study of Outflow Tract and Mid Ventricular Sites
    Rosso, Raphael
    Medi, Caroline
    Teh, Andrew W.
    Hung, Thuy To
    Feldman, Alexander
    Lee, Geoffrey
    Mond, Harry G.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (10): : 1169 - 1173
  • [20] Right Ventricular Septal Pacing: The Success of Stylet-Driven Active-Fixation Leads
    Rosso, Raphael
    Teh, Andrew W.
    Medi, Caroline
    Hung, Thuy To
    Balasubramaniam, Richard
    Mond, Harry G.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (01): : 49 - 53