Identifying risk factors for early neurological outcomes following thoracic endovascular aortic repair using the SUMMIT database

被引:11
作者
Tsilimparis, Nikolaos [1 ]
Stana, Jan [1 ]
Konstantinou, Nikolaos [1 ]
Chen, Min [2 ]
Zhou, Qing [2 ]
Koelbel, Tilo [3 ]
机构
[1] Ludwig Maximilians Univ Hosp, Dept Vasc Surg, Munich, Germany
[2] Cook Res Inc, W Lafayette, IN USA
[3] Univ Heart & Vasc Ctr, German Aort Ctr, Hamburg, Germany
关键词
Aortic aneurysm; Aortic dissection; Thoracic aortic pathology; Thoracic endovascular aortic repair; SUBCLAVIAN ARTERY COVERAGE; SPINAL-CORD ISCHEMIA; PERIOPERATIVE STROKE; ANEURYSM REPAIR; CLINICAL-TRIAL; GRAFT; MULTICENTER; DISSECTION;
D O I
10.1093/ejcts/ezab476
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: The aim of this study was to assess risk factors for early neurological complications following thoracic endovascular aortic repair (TEVAR) for multiple thoracic aortic diseases using an aggregated dataset. METHODS: The Study to Assess Outcomes After Endovascular Repair for Multiple Throacic Aortic Disease dataset included data from 6 studies evaluating Zenith thoracic endografts. Post hoc analysis identified early (30-day) neurological complications by TEVAR indication and corresponding risk factors. RESULTS: The study included 594 TEVAR patients (67% male; mean age 66 +/- 15 years) with thoracic aortic aneurysm (n = 329), ulcer (n = 56), acute (n = 126) or non-acute (n = 33) type B aortic dissection (TBAD) or blunt injury (n = 50). Overall early stroke rate was 3.5% (n = 21). Overall early paraplegia and paraparesis rates were 1.3% (n = 8) and 2.5% (n = 15), respectively. Multivariable analysis identified acute TBAD [versus others, odds ratio (OR) = 3.47, 95% confidence internal (CI): 1.41-8.52) and longer procedural time (OR = 1.33, CI: 1.02-1.73) as early stroke risk factors. Risk factors for paraplegia or paraparesis included more endografts deployed (OR= 2.43, CI: 1.30-4.55), older age (OR= 1.05, CI: 1.01-1.10) and higher preoperative serum creatinine (OR= 1.31, CI: 1.05-1.64). Endografts landing proximal to the left subclavian artery (LSA) increased stroke rate (versus distal to the LSA; 6.8% vs 2.3%, P = 0.014). Intraoperative LSA revascularization was performed in 20.9% of patients with endografts proximal to the LSA; revascularization did not significantly alter stroke rate (8.1% with revascularization vs 6.4% without, P = 0.72). CONCLUSIONS: Acute TBAD and prolonged procedure time increased early stroke risk, while more endografts placed, age and preoperative renal impairment increased early paraplegia or paraparesis risk. For acute TBAD, endograft placement proximal to the LSA, but not LSA patency, increased stroke risk.
引用
收藏
页数:8
相关论文
共 29 条
[1]   Transcranial Doppler findings during thoracic endovascular aortic repair [J].
Bismuth, Jean ;
Garami, Zsolt ;
Anaya-Ayala, Javier E. ;
Naoum, Joseph J. ;
El Sayed, Hosam F. ;
Peden, Eric K. ;
Lumsden, Alan B. ;
Davies, Mark G. .
JOURNAL OF VASCULAR SURGERY, 2011, 54 (02) :364-369
[2]   Neurologic complications associated with endovascular repair of thoracic aortic pathology: Incidence and risk factors. A study from the European Collaborators on Stent/Graft Techniques for Aortic Aneurysm Repair (EUROSTAR) Registry [J].
Buth, Jacob ;
Harris, Peter L. ;
Hobo, Roel ;
van Eps, Randolph ;
Cuypers, Philippe ;
Duijm, Lucien ;
Tielbeek, Xander .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (06) :1103-1111
[3]  
CONWAY A, 2020, VASC ENDOVASC SURG, P586
[4]   Neurological complications after left subclavian artery coverage during thoracic endovascular aortic repair: A systematic review and meta-analysis [J].
Cooper, David G. ;
Walsh, Stewart R. ;
Sadat, Umar ;
Noorani, Ayesha ;
Hayes, Paul D. ;
Boyle, Jonathan R. .
JOURNAL OF VASCULAR SURGERY, 2009, 49 (06) :1594-1601
[5]   Initial and midterm results of the Bolton Relay Thoracic Aortic Endovascular Pivotal Trial [J].
Farber, Mark A. ;
Lee, W. Anthony ;
Szeto, Wilson Y. ;
Panneton, Jean M. ;
Kwolek, Christopher J. .
JOURNAL OF VASCULAR SURGERY, 2017, 65 (06) :1556-1566
[6]   Extent of Aortic Coverage and Incidence of Spinal Cord Ischemia After Thoracic Endovascular Aneurysm Repair [J].
Feezor, Robert J. ;
Martin, Tomas D. ;
Hess, Philip J., Jr. ;
Daniels, Michael J. ;
Beaver, Thomas M. ;
Klodell, Charles T. ;
Lee, W. Anthony .
ANNALS OF THORACIC SURGERY, 2008, 86 (06) :1809-1814
[7]  
Feezor RJ, 2007, J ENDOVASC THER, V14, P568, DOI 10.1583/1545-1550(2007)14[568:RFFPSD]2.0.CO
[8]  
2
[9]   Risk factors for perioperative stroke after thoracic endovascular aortic repair [J].
Gutsche, Jacob T. ;
Cheung, Albert T. ;
McGarvey, Michael L. ;
Moser, William G. ;
Szeto, Wilson ;
Carpenter, Jeffrey P. ;
Fairman, Ronald M. ;
Pochettino, Alberto ;
Bavaria, Joseph E. .
ANNALS OF THORACIC SURGERY, 2007, 84 (04) :1195-1200
[10]   Meta-analysis of Left Subclavian Artery Coverage With and Without Revascularization in Thoracic Endovascular Aortic Repair [J].
Hajibandeh, Shahin ;
Hajibandeh, Shahab ;
Antoniou, Stavros A. ;
Torella, Francesco ;
Antoniou, George A. .
JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (04) :634-641