Determination of Minimal Hemoglobin Level Necessary for Normothermic Porcine Ex Situ Liver Perfusion

被引:14
作者
Bral, Mariusz [1 ,2 ]
Gala-Lopez, Boris [1 ,2 ]
Thiesen, Aducio [1 ]
Hatami, Sanaz [1 ,2 ]
Bigam, David L. [1 ]
Freed, Darren M. [1 ,2 ]
Shapiro, A. M. James [1 ,2 ]
机构
[1] Univ Alberta, Dept Surg, Edmonton, AB, Canada
[2] Canadian Natl Transplant Res Project CNTRP, Edmonton, AB, Canada
关键词
MACHINE PERFUSION; ORGAN-PRESERVATION; OXYGEN CARRIER; SUPERIOR PRESERVATION; CIRCULATORY DEATH; DECLINED LIVER; CARDIAC DEATH; DONOR LIVERS; DCD LIVERS; TRANSPLANTATION;
D O I
10.1097/TP.0000000000002272
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background In current studies of ex situ liver perfusion there exists considerable variability in perfusate composition, including the type of oxygen carrier. Herein, we aim to clarify the minimal hemoglobin level necessary during normothermic porcine ex situ liver perfusion. Methods Livers procured from 35 to 45 kg domestic pigs were connected to our experimental ex situ circuit (n = 10). In the treatment group, perfusate was sequentially diluted hourly to predetermined hemoglobin levels. At the end of each hemoglobin dilution, perfusate samples were analyzed for liver transaminases, lactate dehydrogenase (LD), total bilirubin, and lactate levels. Liver oxygen consumption was measured. In the control group, livers were perfused continually for a duration of 24 hours at target hemoglobin levels of 30 and 20 g/L. Results Rising liver transaminases, significantly higher lactate (P < 0.001), and LD levels (P < 0.001) were noted at lower perfusate hemoglobin levels in the treatment group. Liver oxygen utilization (P < 0.001) and hepatic artery oxygen delivery (P < 0.001) were significantly lower at lower hemoglobin levels, whereas liver vessel resistance remained relatively constant. Histology demonstrated increasing parenchymal damage at lower hemoglobin levels. In control livers, higher perfusate transaminases, higher lactate, and LD levels were noted at a perfusion hemoglobin level of 20 g/L. Conclusions Ex situ liver function decompensated during perfusion between a mean hemoglobin level of 30 to 20 g/L, as evidenced by notably rising lactate and LD levels. This study demonstrates optimal hemoglobin concentration during normothermic ex situ liver perfusion to ensure a fully metabolically functioning graft.
引用
收藏
页码:1284 / 1292
页数:9
相关论文
共 36 条
[1]   Survival following liver transplantation from non-heart-beating donors [J].
Abt, PL ;
Desai, NM ;
Crawford, MD ;
Forman, LM ;
Markmann, JW ;
Olthoff, KM ;
Markmann, JF .
ANNALS OF SURGERY, 2004, 239 (01) :87-92
[2]   Normothermic Machine Perfusion of Deceased Donor Liver Grafts Is Associated With Improved Postreperfusion Hemodynamics [J].
Angelico, Roberta ;
Perera, Thamara P. R. ;
Ravikumar, Reena ;
Holroyd, David ;
Coussios, Constantin ;
Mergental, Hynek ;
Isaac, John R. ;
Iqbal, Asim ;
Cilliers, Hentie ;
Muiesan, Paolo ;
Friend, Peter J. ;
Mirza, Darius F. .
TRANSPLANTATION DIRECT, 2016, 2 (09) :E97
[3]   Normothermic extracorporeal liver perfusion for donation after cardiac death (DCD) livers [J].
Banan, Babak ;
Chung, Haniee ;
Xiao, Zhenyu ;
Tarabishy, Yaman ;
Jia, Jianluo ;
Manning, Pamela ;
Upadhya, G. A. ;
Mohanakumar, Thalachallour ;
Lin, Yiing ;
Chapman, William C. .
SURGERY, 2015, 158 (06) :1643-1651
[4]   Normothermic Acellular Ex Vivo Liver Perfusion Reduces Liver and Bile Duct Injury of Pig Livers Retrieved After Cardiac Death [J].
Boehnert, M. U. ;
Yeung, J. C. ;
Bazerbachi, F. ;
Knaak, J. M. ;
Selzner, N. ;
McGilvray, I. D. ;
Rotstein, O. D. ;
Adeyi, O. A. ;
Kandel, S. M. ;
Rogalla, P. ;
Yip, P. M. ;
Levy, G. A. ;
Keshavjee, S. ;
Grant, D. R. ;
Selzner, M. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2013, 13 (06) :1441-1449
[5]   Preliminary Single-Center Canadian Experience of Human Normothermic Ex Vivo Liver Perfusion: Results of a Clinical Trial [J].
Bral, M. ;
Gala-Lopez, B. ;
Bigam, D. ;
Kneteman, N. ;
Malcolm, A. ;
Livingstone, S. ;
Andres, A. ;
Emamaullee, J. ;
Russell, L. ;
Coussios, C. ;
West, L. J. ;
Friend, P. J. ;
Shapiro, A. M. J. .
AMERICAN JOURNAL OF TRANSPLANTATION, 2017, 17 (04) :1071-1080
[6]   Normothermic Perfusion A New Paradigm for Organ Preservation [J].
Brockmann, Jens ;
Reddy, Srikanth ;
Coussios, Constantin ;
Pigott, David ;
Guirriero, Dino ;
Hughes, David ;
Morovat, Alireza ;
Roy, Debabrata ;
Winter, Lucy ;
Friend, Peter J. .
ANNALS OF SURGERY, 2009, 250 (01) :1-6
[7]   Risk factors for primary dysfunction after liver transplantation in the University of Wisconsin solution era [J].
Brokelman, W ;
Stel, AL ;
Ploeg, RJ .
TRANSPLANTATION PROCEEDINGS, 1999, 31 (05) :2087-2090
[8]   Successful extracorporeal porcine liver perfusion for 72 hr [J].
Butler, AJ ;
Rees, MA ;
Wight, DGD ;
Casey, ND ;
Alexander, G ;
White, DJG ;
Friend, PJ .
TRANSPLANTATION, 2002, 73 (08) :1212-1218
[9]   Comparison of BQ123, Epoprostenol, and Verapamil as Vasodilators During Normothermic Ex Vivo Liver Machine Perfusion [J].
Echeverri, Juan ;
Goldaracena, Nicolas ;
Kaths, Johan Moritz ;
Linares, Ivan ;
Roizales, Roizar ;
Kollmann, Dagmar ;
Hamar, Matyas ;
Urbanellis, Peter ;
Ganesh, Sujani ;
Adeyi, Oyedele A. ;
Tazari, Mahmood ;
Selzner, Markus ;
Selzner, Nazia .
TRANSPLANTATION, 2018, 102 (04) :601-608
[10]   Superior Preservation of DCD Livers With Continuous Normothermic Perfusion [J].
Fondevila, Constantino ;
Hessheimer, Amelia J. ;
Maathuis, Mark-Hugo J. ;
Munoz, Javier ;
Taura, Pilar ;
Calatayud, David ;
Leuvenink, Henri ;
Rimola, Antoni ;
Ploeg, Rutger J. ;
Garcia-Valdecasas, Juan C. .
ANNALS OF SURGERY, 2011, 254 (06) :1000-1007