Modification of ion chromatographic separations by ionic and nonionic surfactants

被引:23
作者
Fritz, JS
Yan, Z
Haddad, PR
机构
[1] Iowa State Univ, US Dept Energy, Ames Lab, Ames, IA 50011 USA
[2] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
[3] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
[4] Zhejiang Univ, Dept Chem, Hangzhou 310028, Peoples R China
关键词
coated columns; dynamic coating; surfactants; inorganic anions; inorganic cations; organic acids;
D O I
10.1016/S0021-9673(03)00114-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
New findings are reported on simple ways to modify an ordinary HPLC column to obtain efficient ion chromatographic (IC) separations. Permanently coating a column with an ionic surfactant is known to produce an effective column for IC. We now show that incorporation of a nonionic surfactant in the coating, or coating in separate layers, results in a dramatic reduction of ion retention times and gives sharper peaks. Dynamic coating by incorporating a small amount of an alcohol, diol or zwitterion in the aqueous mobile phase permits good separations of alkanecarboxylic acids. A mobile phase containing a quaternary ammonium cation and a zwitterion anion provides excellent separations of common anions on a silica C, column. An aqueous eluent containing a mixture of a zwitterion 4-(2-hydroxyethyl) acid and methanesulfonic acid can be used in conjunction with a standard cation exchange column. After passing through a membrane suppressor, the mobile phase has a slightly acidic pH, permitting divalent transition metal ions (as well as others) to be detected by conductivity. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:21 / 31
页数:11
相关论文
共 30 条
[1]   CHROMATE AS A MOBILE-PHASE FOR THE DETERMINATION OF ANIONS USING CETYLTRIMETHYLAMMONIUM-COATED COLUMNS AND INDIRECT PHOTOMETRIC DETECTION [J].
ALBAZI, SJ ;
GHARIB, T ;
CORTES, JC .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (03) :489-503
[2]   PREPARATION OF A POROUS MICROPARTICULATE ANION-EXCHANGE CHROMATOGRAPHY SUPPORT FOR PROTEINS [J].
ALPERT, AJ ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1979, 185 (DEC) :375-392
[3]  
[Anonymous], ION CHROMATOGRAPHY P
[4]   DYNAMICALLY COATED COLUMNS AND CONDUCTIVITY DETECTION FOR TRACE DETERMINATION OF ORGANIC-ANIONS BY ION CHROMATOGRAPHY [J].
CASSIDY, RM ;
ELCHUK, S .
JOURNAL OF CHROMATOGRAPHY, 1983, 262 (JUN) :311-315
[5]   Fast ion chromatography of common inorganic anions on a short ODS column permanently coated with didodecyldimethylammonium bromide [J].
Connolly, D ;
Paull, B .
JOURNAL OF CHROMATOGRAPHY A, 2002, 953 (1-2) :299-303
[6]   A mechanism of separation in electrostatic ion chromatography [J].
Cook, HA ;
Hu, WZ ;
Fritz, JS ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3022-3027
[7]   COATED ANION-EXCHANGE RESINS FOR ION CHROMATOGRAPHY [J].
DUVAL, DL ;
FRITZ, JS .
JOURNAL OF CHROMATOGRAPHY, 1984, 295 (01) :89-101
[8]  
FRITZ JS, 2000, ION CHROMATOGRAPHY, pCH8
[9]   Ion chromatography retrospective [J].
Haddad, PR .
ANALYTICAL CHEMISTRY, 2001, 73 (09) :266A-273A
[10]   FACTORS AFFECTING RETENTION OF BASIC SOLUTES IN ION-EXCLUSION CHROMATOGRAPHY USING AN ANION-EXCHANGE COLUMN [J].
HADDAD, PR ;
HAO, FP ;
GLOD, BK .