Attenuation correction in myocardial perfusion SPECT/CT: Effects of misregistration and value of reregistration

被引:96
作者
Goetze, Sibyll
Brown, Tracy L.
Lavely, William C.
Zhang, Zhe
Bengel, Frank M.
机构
[1] Johns Hopkins Univ, PET, Div Nucl Med, Baltimore, MD 21287 USA
[2] Univ Alabama, Div Nucl Med, Birmingham, AL USA
[3] Johns Hopkins Univ, Div Biostat, Baltimore, MD 21218 USA
关键词
SPECT/CT; hybrid imaging; attenuation correction; myocardial perfusion imaging;
D O I
10.2967/jnumed.107.040535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/ CT and the performance of a software-based approach for reregistration. Methods: We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/ CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight. Results: The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 +/- 3.8 mm (1.25 +/- 0.55 pixel). Misregistration of one or more pixels was observed in 64% of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration. Conclusion: Misregistration occurs with SPECT/CT systems and influences regional tracer distribution on attenuation-corrected myocardial images. Reregistration of misaligned studies may be a useful tool for correction. The impact of this strategy on the diagnostic and prognostic accuracy of cardiac hybrid imaging needs to be determined.
引用
收藏
页码:1090 / 1095
页数:6
相关论文
共 11 条
[1]   Automated quality control of emission-transmission misalignment for attenuation correction in myocardial perfusion imaging with SPECT-CT systems [J].
Chen, J ;
Caputlu-Wilson, SF ;
Shi, HC ;
Galt, JR ;
Faber, TL ;
Garcia, EV .
JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (01) :43-49
[2]  
Fricke H, 2004, J NUCL MED, V45, P1619
[3]   American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: Attenuation correction of myocardial perfusion SPECT scintigraphy [J].
Heller, GV ;
Links, J ;
Bateman, TM ;
Ziffer, JA ;
Ficaro, E ;
Cohen, MC ;
Hendel, RC .
JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (02) :229-230
[4]   Clinical significance of apical thinning after attenuation correction [J].
Links, JM ;
Becker, LC ;
Anstett, F .
JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (01) :26-31
[5]  
Martinez-Möller A, 2007, J NUCL MED, V48, P188
[6]   Clinical validation of SPECT attenuation correction using X-ray computed tomography-derived attenuation maps: Multicenter clinical trial with angiographic correlation [J].
Masood, Y ;
Liu, YH ;
DePuey, G ;
Taillefer, R ;
Araujo, LI ;
Allen, S ;
Delbeke, D ;
Anstett, F ;
Peretz, A ;
Zito, MJ ;
Tsatkin, V ;
Wackers, FJT .
JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (06) :676-686
[7]  
Matsunari I, 1998, J NUCL MED, V39, P411
[8]   A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models [J].
O'Connor, MK ;
Kemp, B ;
Anstett, F ;
Christian, P ;
Ficaro, EP ;
Frey, E ;
Jacobs, M ;
Kritzman, JN ;
Pooley, RA ;
Wilk, M .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (04) :361-376
[9]  
Stone CD, 1998, J NUCL MED, V39, P365
[10]   Effect of nipradilol on silent myocardial ischemia and heart rate variability in chronic stable angina [J].
Takase, B ;
Hikita, H ;
Satomura, K ;
Mastui, T ;
Ohsuzu, F ;
Kurita, A .
CARDIOVASCULAR DRUGS AND THERAPY, 2002, 16 (01) :43-51