Real-time myocardial contrast echocardiography for the detection of stress-induced myocardial ischemia

被引:2
|
作者
Dubart, AE
da Silva, KGC
Korosoglou, G
Bekeredjian, R
Hanson, A
Hardt, S
Rosenberg, M
Ferrari, N
Hoerig, B
Zehelein, J
Kuecherer, H
机构
[1] Dept Cardiol Innere Med III, D-69120 Heidelberg, Germany
[2] Univ Lille, Clin Invest Ctr, Lille, France
来源
ZEITSCHRIFT FUR KARDIOLOGIE | 2004年 / 93卷 / 11期
关键词
contrast echocardiography; myocardial perfusion; myocardial ischemia; coronary artery disease; perfusion imaging;
D O I
10.1007/s00392-004-0144-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Realtime contrast echocardiography (MCE) is a new promising technique for assessing myocardial perfusion. The purpose of this study was to test whether realtime MCE can be used to detect functionally significant coronary artery stenosis in patients with known or suspected coronary artery disease. Myocardial contrast echo cardiographic studies were compared with nearly simultaneous 99mTc-sestamibi single photon emission computed tomography (SPECT) as a clinical standard reference to evaluate regional myocardial perfusion defects. Methods Real-time MCE based on continuous infusion of Optison (8-10 ml/h) was performed in 66 patients during standard 99mTc-SPECT dipyrida-mole (0.56 mg/kg x 4 min) stress testing. Images were obtained in apical 4- and 2-chamber views, each divided into 6 segments. Tracer uptake and myocardial opacification were visually analyzed for each segment by two pairs of blinded observers and graded as normal, mildly reduced, severely reduced, or absent. In 792 myocardial segments, myocardial opacification by MCE was uninterpretable in 143 (18%) segments and tracer uptake by SPECT was not clearly defined in 92 (12%) segments. Interobserver variability for MCE was good with concordance rates of 83% (K = 0.72) for rest- and 86% (K = 0.76) for stress images. Overall concordance between MCE and SPECT was good (83%, K = 0.63) at a segmental level. In the diagnosis of fixed and reversible defects, and of normal perfusion, concordance rates were 73, 65 and 83%, respectively. When analysis was performed at the regional level, we found comparable levels of concordance rates for LAD (83%, K = 0.59), LCX (86%, K = 0.64) and RCA (80%, K = 0.68) perfusion territories. Conclusions These findings suggest that realtime MCE is a clinically acceptable method to evaluate myocardial perfusion defects during dipyridamole stress testing.
引用
收藏
页码:890 / +
页数:7
相关论文
共 50 条
  • [41] Absolute myocardial blood flow determination using real-time myocardial contrast echocardiography during adenosine stress: comparison with single-photon emission computed tomography
    Abdelmoneim, S. S.
    Dhoble, A.
    Bernier, M.
    Moir, S.
    Hagen, M. E.
    Ness, S. A. C.
    Abdel-Kader, S. S.
    Pellikka, P. A.
    Mulvagh, S. L.
    HEART, 2009, 95 (20) : 1662 - 1668
  • [42] Detection of induced myocardial ischemia during stress cardiovascular magnetic resonance
    Barbou, F.
    Lahutte, M.
    Schiano, P.
    Monsegu, J.
    ANNALES DE CARDIOLOGIE ET D ANGEIOLOGIE, 2011, 60 (01): : 42 - 47
  • [43] Use of Electrocardiographic Depolarization Abnormalities for Detection of Stress-Induced Ischemia as Defined by Myocardial Perfusion Imaging
    Sharir, Tali
    Merzon, Konstantine
    Kruchin, Iren
    Bojko, Andrzej
    Toledo, Eran
    Asman, Arik
    Chouraqui, Pierre
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (05): : 642 - 650
  • [44] Accelerated stress real-time myocardial contrast echocardiography for the detection of coronary artery disease: Comparison with 99mTc single photon emission computed tomography
    Lipiec, Piotr
    Wejner-Mik, Paulina
    Krzeminska-Pakula, Maria
    Kusmierek, Jacek
    Plachcinska, Anna
    Szuminski, Remigiusz
    Peruga, Jan Z.
    Kasprzak, Jaroslaw D.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (08) : 941 - 947
  • [45] SUBENDOCARDIAL MYOCARDIAL-ISCHEMIA AS ASSESSED WITH MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY IN PATIENTS WITH ISCHEMIC HEART-DISEASES
    LIM, YJ
    NANTO, S
    MASUYAMA, T
    HORI, M
    BIORHEOLOGY, 1993, 30 (5-6) : 349 - 358
  • [46] Detection of resting myocardial perfusion defects by SonoVue® myocardial contrast echocardiography
    Nahar, T
    Li, P
    Kuersten, B
    Batra, S
    Vannan, MA
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2003, 20 (06): : 511 - 517
  • [47] Real-time dobutamine stress myocardial contrast echocardiography for detecting coronary artery disease: Correlating abnormal wall motion and disturbed perfusion
    Chiou, KR
    Huang, WC
    Lin, SL
    Hsieh, PL
    Liu, CP
    Tsay, DG
    Chiang, HT
    CANADIAN JOURNAL OF CARDIOLOGY, 2004, 20 (12) : 1237 - 1243
  • [48] Myocardial perfusion imaging using contrast echocardiography
    Nesser, HJ
    Morcerf, F
    Teupe, C
    Pandian, NG
    HERZ, 2002, 27 (03) : 217 - 226
  • [49] Myocardial Contrast Echocardiography for Simultaneous Assessment of Function and Perfusion in Real Time A Technique Comes of Age
    Senior, Roxy
    Shah, Benoy N.
    CIRCULATION, 2012, 126 (10) : 1182 - 1184
  • [50] Myocardial Perfusion Imaging Using Contrast Echocardiography
    Pathan, Faraz
    Marwick, Thomas H.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2015, 57 (06) : 632 - 643