Sensitivity Analysis of the Constructive Parameters for the 2 x 25-kV High-Speed Railway Lines Planning

被引:22
作者
Brenna, Morris [1 ]
Foiadelli, Federica [1 ]
机构
[1] Politecn Milan, Dept Energy, I-20156 Milan, Italy
关键词
Autotransformer; current distribution; high-speed trains; line inductance; railway lines planning;
D O I
10.1109/TPWRD.2010.2042977
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a study of the AC 2 x 25 kV-50-Hz system for the train power supply, giving a valid instrument for better design of the future railway lines. In fact, different constructive solutions, such as the autotransformer short-circuit voltage, can influence the correct working of the system. The analysis of the real currents distribution between the 2 x 25-kV system branches is presented, overcoming the circuital simplifications adopted in the traditional studies that have now been documented in the literature. The study is validated through simulation and in-field measurements.
引用
收藏
页码:1923 / 1931
页数:9
相关论文
共 14 条
[1]  
BUFFARINI GG, 2005, INGEGNERIA FERROVIAR, V2
[2]   Traction system unbalance problem - Analysis methodologies [J].
Chen, SL ;
Li, RJ ;
Hsi, PH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) :1877-1883
[3]  
COURTOIS C, 1993, IEE C 50 KV AUT TRAC
[4]  
GAGGELLI A, 1999, CAMPAGNA MISURE VERI
[5]  
HILL RJ, 1990, P ASME IEEE JOINT RA, P157
[6]  
HOWROYD DC, 1989, IEE CONF PUBL, V312, P260
[7]  
Lucca G., 2007, EUR T ELECTR POWER, V13, P285
[8]  
MORETTI M, 2004, IEEE INT VEH S PARM
[9]  
Morrison RE, 2001, 2001 POWER ENGINEERING SOCIETY SUMMER MEETING, VOLS 1-3, CONFERENCE PROCEEDINGS, P204, DOI 10.1109/PESS.2001.970013
[10]   COMPUTATION OF TRANSMISSION-LINE INDUCTANCE AND CAPACITANCE MATRICES FROM GENERALIZED CAPACITANCE MATRIX [J].
PAUL, CR ;
FEATHER, AE .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1976, 18 (04) :175-183