NIR Photoacoustic Spectroscopy for Non-Invasive Glucose Measurement

被引:0
|
作者
Pai, Praful P. [1 ]
Sanki, Pradyut Kumar [1 ]
De, Arijit [1 ]
Banerjee, Swapna [1 ]
机构
[1] Indian Inst Technol, Dept Elect & Elect Commun Engn, Kharagpur 721302, W Bengal, India
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of near infra red (NIR) photoacoustic spectroscopy (PAS) for continuous non-invasive glucose measurement is outlined in the paper. A photoacoustic (PA) measurement apparatus was constructed and PA measurements were made on glucose solutions at multiple NIR excitation wavelengths. A variety of time and frequency domain features, including amplitude and area based features, were extracted from the PA measurements. These features were observed to be proportional to the glucose concentration of the sample. PA measurements from samples of whole blood at different glucose concentrations showed similar results. Subsequently, in vivo PA measurements made on a cohort of 30 volunteers were calibrated using a quadratic fit, and the results were compared to reference glucose concentrations made using a regular blood glucose meter. A comparison of 196 measurement pairs of predicted and reference glucose concentrations using a Clarke Error Grid gave a point distribution of 87.24% and 12.76% over zones A and B of the grid, with no measurement pairs falling in unacceptable zones C-E of the error grid. The predicted measurements had a mean absolute difference (MAD) of 12.57 +/- 13.90 mg/dl and a mean absolute relative difference (MARD) of 9.61% +/- 10.55%. This is an improvement over previous results obtained using PAS and other non-invasive techniques, validating the potential of PAS for continuous non-invasive glucose monitoring.
引用
收藏
页码:7978 / 7981
页数:4
相关论文
共 50 条
  • [41] Resonant photoacoustic spectroscopy for a non-invasive blood glucose monitoring: human interface and temperature correction technology
    Tanaka, Y.
    Tajima, T.
    Seyama, M.
    Waki, K.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2019, 2019, 10878
  • [42] Regularized Least Squares Regression for Calibration of a Photoacoustic Spectroscopy based Non-Invasive Glucose Monitoring System
    Pai, Praful P.
    Bhattacharya, Sourangshu
    Banerjee, Swapna
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [43] Low Energy Fluence Photoacoustic Spectroscopy for Non-invasive Glucose Monitor Coherent photoacoustic beam orthogonally propagating to light beam
    Tanaka, Yujiro
    Seyama, Michiko
    Ikeda, Teiichiro
    2019 IEEE SENSORS, 2019,
  • [44] Identification of informative bands in the short-wavelength NIR region for non-invasive blood glucose measurement
    Uwadaira, Yasuhiro
    Ikehata, Akifumi
    Momose, Akiko
    Miura, Masayo
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (07): : 2729 - 2737
  • [45] Non-Invasive Blood Glucose Measurement Using Near Infra-Red Spectroscopy
    Priyoti, Anika Tabassum
    Jim, Salman Jubair
    Hossain, Sushmit
    Mahmud, Shafkat
    Salvin, Sujana
    Bhattacharjee, Arnab
    PROCEEDINGS OF 2019 IEEE R10 HUMANITARIAN TECHNOLOGY CONFERENCE (IEEE R10 HTC 2019), 2019, : 1 - 4
  • [46] Evaluation of a new photoacoustic non-invasive continuous glucose monitor.
    Argaman, D
    Ashkenazi, S
    Greenberg, L
    Raz, I
    DIABETOLOGIA, 2003, 46 : A309 - A309
  • [47] Non-Invasive Measurement of Blood Flow Velocity Based on Photoacoustic Calorimetric Measurement
    Xu L.
    Zhang H.
    Li D.
    Chen B.
    Zheng Y.
    Yao L.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2024, 51 (03):
  • [48] Non-Invasive Measurement of Blood Flow Velocity Based on Photoacoustic Calorimetric Measurement
    Xu, Luhan
    Hao, Zhang
    Dong, Li
    Bin, Chen
    Zheng, Yuping
    Yao, Liang
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2024, 51 (03):
  • [49] Non-invasive Blood Glucose Measurement Scheme Based on Near-infrared Spectroscopy
    Wang Shulei
    Yuan Xueguang
    Zhang Yangan
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [50] Non-invasive measurement of glycogen/glucose and glial neurochemistry in vivo using NMR spectroscopy
    Gruetter, R
    Oz, G
    Henry, PG
    Lei, H
    Pfeuffer, J
    Tkac, I
    Choi, IY
    Seaquist, E
    GLIA, 2003, : 5 - 5