Investigation on seismic performance and shear strength of high-strength concrete-filled polyvinyl chloride tube short columns

被引:3
作者
Xue, Jianyang [1 ]
Zhao, Xiangbi [1 ]
Zhang, Fengliang [2 ]
Ke, Xiaojun [3 ]
Ma, Linlin [1 ]
Xu, Dan [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Shaanxi, Peoples R China
[2] Shaanxi Architecture Sci Res Inst Co Ltd, Shaanxi Shaanxi Jianke Construct Special Engn Co, Xian, Shaanxi, Peoples R China
[3] Guangxi Univ, Coll Civil Engn & Architecture, Nanning, Peoples R China
基金
中国国家自然科学基金;
关键词
high-strength concrete; high-strength concrete-filled PVCT; quasistatic test; seismic performance; shear strength; RECYCLED AGGREGATE CONCRETE; BEHAVIOR;
D O I
10.1002/tal.1674
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper innovatively designs polyvinyl chloride tube (PVCT) with high-strength concrete (HC) and presents the results of cyclic loading tests on new reinforced high-strength concrete short columns, including three high-strength concrete-filled PVCT (HC-PVCT) short columns, one high-strength concrete-filled steel tube short column and one HC short column. The main objective of this research was to evaluate the seismic behaviors of HC short columns based on the quasistatic test of the columns. The design parameters of the columns in the experiments were axial compression ratio, reinforcement measures, concrete strength, stirrups configuration, and the height-diameter ratio of tubes. The crack distribution, failure modes, hysteresis loops, skeleton curves, energy dissipation capacity, strength degradation, stiffness degradation, and cumulative damage of the columns were presented and analyzed. The results showed that the HC-PVCT column had a fuller hysteretic loop and a higher peak load than the HC column. Compared with HC column, the strength degradation of HC-PVCT columns was slower, and the ductility increased significantly. With a larger axial compression ratio, the ductility of HC-PVCT columns was decreased. Based on the test and analysis results, a modified HC-PVCT design method was proposed to calculate the nominal shear strength of HC-PVCT short columns.
引用
收藏
页数:21
相关论文
共 36 条
  • [1] ABHALE RB, 2016, IMPERIAL J INTERDISC, V2, P1391
  • [2] Cold expansion and reduction of thin-walled PVC tubes using a die
    Alves, L. M.
    Martins, P. A. F.
    [J]. JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2009, 209 (09) : 4229 - 4236
  • [3] [Anonymous], 2006, 91092F AWWARF
  • [4] [Anonymous], 2002, GBT2282002
  • [5] Balasubramani N., 2015, INDIAN J SCI TECHNOL, V8, P11, DOI 10.17485/ijst/2015/v8iS7/62242
  • [6] BOERSMA A, 2005, 9 INT C PVC BRIGHT E
  • [7] Breen J, 2006, TNO Report MT-RAP-06-18692/MSO
  • [8] Recycling and reuse of construction and demolition waste in concrete-filled steel tubes: A review
    Chen, Zongping
    Xu, Jinjun
    Chen, Yuliang
    Lui, Eric M.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 126 : 641 - 660
  • [9] Performance and calculations of recycled aggregate concrete-filled steel tubular (RACFST) short columns under axial compression
    Chen, Zongping
    Xu, Jinjun
    Xue, Jianyang
    Su, Yisheng
    [J]. INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2014, 14 (01) : 31 - 42
  • [10] Chinese Standard, 2010, GB 50011 2010