Biomechanics of artificial intervertebral disc with different materials using finite element method

被引:0
作者
Omran, Lamia Nabil [1 ,4 ]
Ezzat, Kadry Ali [1 ,4 ]
Elhoseny, Mohamed [2 ,4 ]
Hassanien, Aboul Ella [3 ,4 ]
机构
[1] Higher Technol Inst, Biomed Engn Dept, 10th Of Ramadan, Egypt
[2] Mansoura Univ, Fac Comp & Informat, Mansoura, Egypt
[3] Cairo Univ, Fac Comp & Informat, Cairo, Egypt
[4] SRGE, Cairo, Egypt
关键词
Biomechanics; Finite element method; Lumbar spine; Intervertebral disc; Solid part; LUMBAR SPINE; SIMULATION; VERTEBRAE;
D O I
10.1007/s00500-018-3574-2
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The main objective of this paper is to help the orthopaedic in selecting the most suitable artificial intervertebral disc material that can be used in intervertebral disc replacement surgery based on the finite element method. The study uses a three-dimensional model for the lumber 4-lumber 5 spine vertebras for real patient DICOM dataset and saves as stereolithography format. The stereolithography file for the vertebras is converted into a computer-aided diagnostic file to be suitably imported in SolidWorks software. The integrated three-dimensional model assembles and boundary conditions are applied to the model, including axial force applied on the lumber 4-lumber 5 spine. The disc is designed and constructed using SolidWorks, and then four materials are applied to the artificial intervertebral disc. The results show that cobalt-chromium material is the most suitable material to be used in artificial spinal disc according to the maximum stress under an axial compression force of 300 N for cobalt-chromium and titanium was 109,308,136 N/m(2) and 95,111,200 N/m(2), while the maximum stress under an axial extension for cobalt-chromium and titanium was 109,308,136 N/m(2) and 95,111,184 N/m(2). The maximum stress under a right-side bending for cobalt-chromium and titanium was 30,456,905,728 N/m(2) and 29,162,355,200 N/m(2), and the maximum stress under a right-side bending for cobalt-chromium and titanium was 34,716,794,880 N/m(2) and 33,086,228,480 N/m(2).
引用
收藏
页码:9215 / 9236
页数:22
相关论文
共 34 条
  • [1] Design and Computational Modeling of a Modular, Compliant Robotic Assembly for Human Lumbar Unit and Spinal Cord Assistance
    Agarwal, Gunjan
    Robertson, Matthew A.
    Sonar, Harshal
    Paik, Jamie
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [2] BIOMECHANICS OF CERVICAL SPINE FOLLOWING IMPLANTATION OF A SEMI-CONSTRAINED ARTIFICIAL DISC WITH UPWARD CENTER OF ROTATION: A FINITE ELEMENT INVESTIGATION
    Akbarian, D.
    Rouhi, G.
    Mashhadi, M. Mosavi
    Herzog, W.
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (04)
  • [3] Newton-Raphson Solver for Finite Element Methods Featuring Nonlinear Hysteresis Models
    Chama, Abdoulkadri
    Gerber, Stiaan
    Wang, Rong-Jie
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (01)
  • [4] Finite element analysis predicts experimental failure patterns in vertebral bodies loaded via intervertebral discs up to large deformation
    Clouthier, Allison L.
    Hosseini, Hadi S.
    Maquer, Ghislain
    Zysset, Philippe K.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2015, 37 (06) : 599 - 604
  • [5] Cobetto N, 2017, EUR SPINE J, V12, P1
  • [6] Signal intensity loss of the intervertebral discs in the cervical spine of young patients on fluid sensitive sequences
    de Bruin, F.
    ter Horst, S.
    van den Berg, R.
    de Hooge, M.
    van Gaalen, F.
    Fagerli, K. M.
    Landewe, R.
    van Oosterhout, M.
    Bloem, J. L.
    van der Heijde, D.
    Reijnierse, M.
    [J]. SKELETAL RADIOLOGY, 2016, 45 (03) : 375 - 381
  • [7] Estimation of loads on human lumbar spine: A review of in vivo and computational model studies
    Dreischarf, Marcel
    Shirazi-Adl, Aboulfazl
    Arjmand, Navid
    Rohlmann, Antonius
    Schmidt, Hendrik
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (06) : 833 - 845
  • [8] ANALYSIS OF LIVER IMPACT RESPONSES THROUGH A CHINESE HUMAN BODY FINITE ELEMENT MODEL
    Du Tianya
    Chen Jiqing
    Lan Fengchong
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2016, 16 (08)
  • [9] Fu C., 2015, J SHANGHAI JIAOTONG, V49, P300
  • [10] Predictive factors of dysbaric osteonecrosis following musculoskeletal decompression sickness in recreational SCUBA divers
    Gempp, Emmanuel
    Louge, Pierre
    de Maistre, Sebastien
    [J]. JOINT BONE SPINE, 2016, 83 (03) : 357 - 358