Parallel imaging performance as a function of field strength - An experimental investigation using electrodynamic scaling

被引:148
作者
Wiesinger, F
Van De Moortele, PF
Adriany, G
De Zanche, N
Ugurbil, K
Pruessmann, KP
机构
[1] Univ Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ETH, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[3] Univ Minnesota, Sch Med, Ctr MR Res, Dept Radiol, Minneapolis, MN 55455 USA
关键词
MRI; electrodynamic scaling; ultra-high field; parallel imaging; SENSE;
D O I
10.1002/mrm.20281
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, the dependence of parallel MRI performance on main magnetic field strength is experimentally investigated. Using the general framework of electrodynamic scaling, the B-o-dependent behavior of the relevant radiofrequency fields at a single physical field strength of 7 T is studied. In the chosen implementation this is accomplished by adjusting the permittivity and conductivity of a homogeneous spherical phantom. With different mixing ratios of decane, ethanol, purified water, N-methylformamide, and sodium chloride, field strengths in the range of 1.5 to 11.5 T are mimicked. Based on sensitivity maps of an eight-coil receiver array, the field-dependent performance of parallel imaging is assessed in terms of the geometry factor g, which reflects noise enhancement in parallel imaging reconstruction. At low field strengths the SNR penalty was nearly independent of B-o and favorably low for 1D reduction factors up to between 3 and 4. At higher field strengths the transition between favorable and prohibitive parallel imaging conditions was found to shift toward higher feasible reduction factors. These findings are in good agreement with previous theoretical predictions. From this agreement it is concluded that parallel MRI at high B-o benefits specifically from onsetting far-field behavior of the involved radiofrequency fields. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:953 / 964
页数:12
相关论文
共 46 条
[1]  
Adriany G., 2003, P 11 ANN M ISMRM TOR, P474
[2]  
[Anonymous], [No title captured], Patent No. 6633161
[3]   Diffusion tensor imaging using single-shot SENSE-EPI [J].
Bammer, R ;
Auer, M ;
Keeling, SL ;
Augustin, M ;
Stables, LA ;
Prokesch, RW ;
Stollberger, R ;
Moseley, ME ;
Fazekas, F .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) :128-136
[4]   Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz [J].
Collins, CM ;
Yang, QX ;
Wang, JH ;
Zhang, X ;
Liu, H ;
Michaeli, S ;
Zhu, XH ;
Adriany, G ;
Vaughan, JT ;
Anderson, P ;
Merkle, H ;
Ugurbil, K ;
Smith, MB ;
Chen, W .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :1026-1028
[5]   Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging [J].
de Zwart, JA ;
van Gelderen, P ;
Kellman, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :1011-1020
[6]   Design of a SENSE-optimized high-sensitivity MRI receive coil for brain imaging [J].
de Zwart, JA ;
Ledden, PJ ;
Kellman, P ;
van Gelderen, P ;
Duyn, JH .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1218-1227
[7]   The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2271-2293
[8]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270
[9]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[10]  
Hoult DI, 2000, J MAGN RESON IMAGING, V12, P46, DOI 10.1002/1522-2586(200007)12:1<46::AID-JMRI6>3.0.CO