Validation of circulating steroid hormone measurements across different matrices by liquid chromatography-tandem mass spectrometry

被引:4
|
作者
Snaterse, Gido [1 ]
van Dessel, Lisanne F. [2 ]
Taylor, Angela E. [3 ]
Visser, Jenny A. [1 ]
Arlt, Wiebke [3 ]
Lolkema, Martijn P. [2 ]
Hofland, Johannes [1 ]
机构
[1] Erasmus MC, Dept Internal Med, Sect Endocrinol, Univ Med Ctr Rotterdam, Rotterdam, Netherlands
[2] Erasmus MC, Erasmus MC Canc Inst, Univ Med Ctr Rotterdam, Dept Med Oncol, Rotterdam, Netherlands
[3] Univ Birmingham, Inst Metab & Syst Res, Birmingham, W Midlands, England
关键词
Steroids; Androgens; Testosterone; CellSave; LC-MS; MS; INCREASED SURVIVAL; PROSTATE-CANCER; SERUM TUBES; TESTOSTERONE; IMMUNOASSAYS; ANDROGENS; ESTRADIOL; MEN; PERFORMANCE; ABIRATERONE;
D O I
10.1016/j.steroids.2021.108800
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: Steroid hormones are essential signalling molecules in prostate cancer (PC). However, many studies focusing on liquid biomarkers fail to take the hormonal status of these patients into account. Steroid measurements are sensitive to bias caused by matrix effects, thus assessing potential matrix effects is an important step in combining circulating tumour DNA (ctDNA) analysis with hormone status. Methods: We investigated the accuracy of multi-steroid hormone profiling in mechanically-separated plasma (MSP) samples and in plasma from CellSave Preservative (CS) tubes, that are typically used to obtain ctDNA, compared to measurements in serum. We performed multiplex steroid profiling by liquid chromatography-tandem mass spectrometry (LC-MS/MS) in samples obtained from ten healthy controls and ten castrationresistant prostate cancer (CRPC) patients. Results: Steroid measurements were comparable between MSP and serum. A small but consistent decrease of 8-21% compared to serum was observed when using CS plasma, which was considered to be within the acceptable margin. The minimal residual testosterone levels of CRPC patients could be sensitively quantified in both MSP and CS samples. Conclusions: We validated the use of MSP and CS samples for multi-steroid profiling by LC-MS/MS. The optimised use of these samples in clinical trials will allow us to gain further insight into the steroid metabolism in PC patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Liquid chromatography-tandem mass spectrometry assay for human serum testosterone and trideuterated testosterone
    Starcevic, B
    Distefano, E
    Wang, C
    Catlin, DH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 197 - 204
  • [42] Clinical Usefulness of Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for Low Serum Testosterone Measurement
    Cho, Sung-Eun
    Han, Jungsun
    Park, Ju-Hee
    Park, Euna
    Kim, Geun Young
    Lee, Jun Hyung
    Yi, Ahram
    Lee, Sang Gon
    Lee, Eun Hee
    Yun, Yeo-Min
    ANNALS OF LABORATORY MEDICINE, 2023, 43 (01) : 19 - +
  • [43] Steroid profiles in ovarian follicular fluid in women with and without polycystic ovary syndrome, analyzed by liquid chromatography-tandem mass spectrometry
    Naessen, Tord
    Kushnir, Mark M.
    Chaika, Andrey
    Nosenko, Jelena
    Mogilevkina, Iryna
    Rockwood, Alan L.
    Carlstrom, Kjell
    Bergquist, Jonas
    Kirilovas, Dmitrijus
    FERTILITY AND STERILITY, 2010, 94 (06) : 2228 - 2233
  • [44] Serum steroid profiling for Congenital Adrenal Hyperplasia using liquid chromatography-tandem mass spectrometry
    Rossi, Claudia
    Calton, Lisa
    Hammond, Gareth
    Brown, Heather A.
    Wallace, A. Michael
    Sacchetta, Paolo
    Morris, Michael
    CLINICA CHIMICA ACTA, 2010, 411 (3-4) : 222 - 228
  • [45] Establishing and Verifying a Robust Liquid Chromatography-Tandem Mass Spectrometry Method to Simultaneously Measure Seven Androgens Present in Plasma Samples
    Yu, Songlin
    Zou, Yutong
    Yin, Yicong
    Yu, Jialei
    Li, Qianqian
    Xie, Shaowei
    Luo, Wei
    Ma, Xiaoli
    Wang, Danchen
    Qiu, Ling
    SEPARATIONS, 2022, 9 (11)
  • [46] Analysis of steroid hormones in effluents of wastewater treatment plants by liquid chromatography-tandem mass spectrometry
    Ingrand, V
    Herry, G
    Beausse, J
    de Roubin, MR
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (01) : 99 - 104
  • [47] Rapid steroid hormone quantification for congenital adrenal hyperplasia (CAH) in dried blood spots using UPLC liquid chromatography-tandem mass spectrometry
    Janzen, Nils
    Sander, Stefanie
    Terhardt, Michael
    Steuerwald, Ulrike
    Peter, Michael
    Das, Anibh M.
    Sander, Johannes
    STEROIDS, 2011, 76 (13) : 1437 - 1442
  • [48] Development of a multi-class steroid hormone screening method using Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)
    Boggs, Ashley S. P.
    Bowden, John A.
    Galligan, Thomas M.
    Guillette, Louis J., Jr.
    Kucklick, John R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (15) : 4179 - 4190
  • [49] Endogenous steroid profiling by gas chromatography-tandem mass spectrometry and multivariate statistics for the detection of natural hormone abuse in cattle
    Blokland, M. H.
    Van Tricht, E. F.
    Van Rossum, H. J.
    Sterk, S. S.
    Nielen, M. W. F.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (07): : 1030 - 1045
  • [50] Development and Validation of the New Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Unbound Tacrolimus in the Plasma Ultrafiltrate of Transplant Recipients
    Bodnar-Broniarczyk, Magdalena
    Warzyszynska, Karola
    Czerwinska, Katarzyna
    Marszalek, Dorota
    Dziewa, Natalia
    Kosieradzki, Maciej
    Pawinski, Tomasz
    PHARMACEUTICS, 2022, 14 (03)