Effects of Choice of Medical Imaging Modalities on a Non-invasive Diagnostic and Monitoring Computational Framework for Patients With Complex Valvular, Vascular, and Ventricular Diseases Who Undergo Transcatheter Aortic Valve Replacement

被引:16
作者
Baiocchi, Melissa [1 ]
Barsoum, Shirley [1 ]
Khodaei, Seyedvahid [1 ]
de la Torre Hernandez, Jose M. [2 ]
Valentino, Sydney E. [3 ]
Dunford, Emily C. [3 ]
MacDonald, Maureen J. [3 ]
Keshavarz-Motamed, Zahra [1 ,4 ,5 ]
机构
[1] McMaster Univ, Dept Mech Engn, Hamilton, ON, Canada
[2] Hosp Univ Marques Valdecilla, IDIVAL, Santander, Spain
[3] McMaster Univ, Dept Kinesiol, Hamilton, ON, Canada
[4] McMaster Univ, Sch Biomed Engn, Hamilton, ON, Canada
[5] McMaster Univ, Sch Computat Sci & Engn, Hamilton, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
computational model; local hemodynamics; global hemodynamics; workload; diagnostic tool; doppler echocardiography; computed tomography; PRESSURE-VOLUME RELATION; MAGNETIC-RESONANCE; COMPUTED-TOMOGRAPHY; IN-VITRO; RADIATION-EXPOSURE; HEART-FAILURE; STENOSIS; ECHOCARDIOGRAPHY; IMPACT; FLOW;
D O I
10.3389/fbioe.2021.643453
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Due to the high individual differences in the anatomy and pathophysiology of patients, planning individualized treatment requires patient-specific diagnosis. Indeed, hemodynamic quantification can be immensely valuable for accurate diagnosis, however, we still lack precise diagnostic methods for numerous cardiovascular diseases including complex (and mixed) valvular, vascular, and ventricular interactions (C3VI) which is a complicated situation made even more challenging in the face of other cardiovascular pathologies. Transcatheter aortic valve replacement (TAVR) is a new less invasive intervention and is a growing alternative for patients with aortic stenosis. In a recent paper, we developed a non-invasive and Doppler-based diagnostic and monitoring computational mechanics framework for C3VI, called C3VI-DE that uses input parameters measured reliably using Doppler echocardiography. In the present work, we have developed another computational-mechanics framework for C3VI (called C3VI-CT). C3VI-CT uses the same lumped-parameter model core as C3VI-DE but its input parameters are measured using computed tomography and a sphygmomanometer. Both frameworks can quantify: (1) global hemodynamics (metrics of cardiac function); (2) local hemodynamics (metrics of circulatory function). We compared accuracy of the results obtained using C3VI-DE and C3VI-CT against catheterization data (gold standard) using a C3VI dataset (N = 49) for patients with C3VI who undergo TAVR in both pre and post-TAVR with a high variability. Because of the dataset variability and the broad range of diseases that it covers, it enables determining which framework can yield the most accurate results. In contrast with C3VI-CT, C3VI-DE tracks both the cardiac and vascular status and is in great agreement with cardiac catheter data.
引用
收藏
页数:20
相关论文
共 99 条
[1]   Doppler echocardiography: A contemporary review [J].
Anavekar, Nandan S. ;
Oh, Jae K. .
JOURNAL OF CARDIOLOGY, 2009, 54 (03) :347-358
[2]   Side Effects of Radiographic Contrast Media: Pathogenesis, Risk Factors, and Prevention [J].
Andreucci, Michele ;
Solomon, Richard ;
Tasanarong, Adis .
BIOMED RESEARCH INTERNATIONAL, 2014, 2014
[3]   The ventricular-arterial coupling: From basic pathophysiology to clinical application in the echocardiography laboratory [J].
Antonini-Canterin, Francesco ;
Poli, Stefano ;
Vriz, Olga ;
Pavan, Daniela ;
Di Bello, Vitantonio ;
Nicolosi, Gian Luigi .
JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2013, 23 (04) :91-95
[4]   Computational Models and Simulations of Cancer Metastasis [J].
Anvari, Sina ;
Nambiar, Shruti ;
Pang, Jun ;
Maftoon, Nima .
ARCHIVES OF COMPUTATIONAL METHODS IN ENGINEERING, 2021, 28 (07) :4837-4859
[5]   Ventricular stroke work and vascular impedance refine the characterization of patients with aortic stenosis [J].
Ben-Assa, Eyal ;
Brown, Jonathan ;
Keshavarz-Motamed, Zahra ;
de la Torre Hernandez, Jose M. ;
Leiden, Benjamin ;
Olender, Max ;
Kallel, Faouzi ;
Palacios, Igor F. ;
Inglessis, Ignacio ;
Passeri, Jonathan J. ;
Shah, Pinak B. ;
Elmariah, Sammy ;
Leon, Martin B. ;
Edelman, Elazer R. .
SCIENCE TRANSLATIONAL MEDICINE, 2019, 11 (509)
[6]   Hemodynamic Changes following Aortic Valve Bypass: A Mathematical Approach [J].
Benevento, Emilia ;
Djebbari, Abdelghani ;
Keshavarz-Motamed, Zahra ;
Cecere, Renzo ;
Kadem, Lyes .
PLOS ONE, 2015, 10 (04)
[7]  
Benjamin EJ, 2019, CIRCULATION, V139, pE56, DOI [10.1161/CIR.0000000000000659, 10.1161/CIR.0000000000000746]
[8]  
Blanke P., 2016, PREDICTING LVOT OBST
[9]   Temporal Trends in the Utilization of Echocardiography in Ontario, 2001 to 2009 [J].
Blecker, Saul ;
Bhatia, R. Sacha ;
You, John J. ;
Lee, Douglas S. ;
Alter, David A. ;
Wang, Julie T. ;
Wong, Hannah J. ;
Tu, Jack V. .
JACC-CARDIOVASCULAR IMAGING, 2013, 6 (04) :515-522
[10]  
Borlaug Barry A, 2008, Heart Fail Clin, V4, P23, DOI 10.1016/j.hfc.2007.10.001