Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface

被引:22
|
作者
Meng, Qingen [1 ]
Gao, Leiming [1 ]
Liu, Feng [1 ]
Yang, Peiran [2 ]
Fisher, John [1 ]
Jin, Zhongmin [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
[2] Qingdao Technol Univ, Sch Mech Engn, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Contact mechanics; Elastohydrodynamic lubrication; Metal-on-metal hip implants; Aspherical bearing surfaces; WEAR PARTICLES; RESURFACING CUPS; ION RELEASE; IN-VITRO; DEFORMATION; JOINTS; PREDICTION; PROSTHESES; CLEARANCE; DIAMETER;
D O I
10.1016/j.jbiomech.2009.11.018
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Diameter and diametral clearance of the bearing surfaces of metal-on-metal hip implants and structural supports have been recognised as key factors to reduce the dry contact and hydrodynamic pressures and improve lubrication performance. On the other hand, application of aspherical bearing surfaces can also significantly affect the contact mechanics and lubrication performance by changing the radius of the curvature of a bearing surface and consequently improving the conformity between the head and the cup. In this study, a novel metal-on-metal hip implant employing a specific aspherical bearing surface, Alpharabola, as the acetabular surface was investigated for both contact mechanics and elastohydrodynamic lubrication under steady-state conditions. When compared with conventional spherical bearing surfaces, a more uniform pressure distribution and a thicker lubricant film thickness within the loaded conjunction were predicted for this novel Alpharabola hip implant. The effects of the geometric parameters of this novel acetabular surface on the pressure distribution and lubricant thickness were investigated. A significant increase in the predicted lubricant film thickness and a significant decrease in the dry contact and hydrodynamic pressures were found with appropriate combinations of these geometric parameters, compared with the spherical bearing surface. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:849 / 857
页数:9
相关论文
共 50 条
  • [31] Lubrication of metal-on-metal hip joints: The effect of protein content and load on film formation and wear
    Myant, C.
    Underwood, R.
    Fan, J.
    Cann, P. M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 6 : 30 - 40
  • [32] Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses
    Liu, Feng
    Jin, Zhongmin
    Roberts, P.
    Grigoris, P.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H6) : 695 - 704
  • [33] Chromium speciation in the blood of metal-on-metal hip implant patients
    Finley, Brent
    Scott, Paul K.
    Glynn, Meghan E.
    Paustenbach, Dennis
    Donovan, Ellen
    Thuett, Kerry A.
    TOXICOLOGICAL AND ENVIRONMENTAL CHEMISTRY, 2017, 99 (01) : 48 - 64
  • [34] Surface Engineering: A Low Wearing Solution for Metal-On-Metal Hip Surface Replacements
    Leslie, Ian J.
    Williams, Sophie
    Brown, Chris
    Anderson, James
    Isaac, Graham
    Hatto, Peter
    Ingham, Eileen
    Fisher, John
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 90B (02) : 558 - 565
  • [35] Wear Simulation of Metal-on-Metal Hip Replacements With Frictional Contact
    Mattei, Lorenza
    Di Puccio, Francesca
    JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 2013, 135 (02):
  • [36] Can a "pre-worn" bearing surface geometry reduce the wear of metal-on-metal hip replacements? - A numerical wear simulation study
    Gao, Leiming
    Hua, Zikai
    Hewson, Robert
    WEAR, 2018, 406 : 13 - 21
  • [37] Different Loading and Motion Applied on Hip Simulators Affects the Lubrication of Metal-on-Metal Hip Implants
    Gao, Leiming
    Yang, Peiran
    Wang, Fengcai
    Jin, Zhongmin
    ADVANCED TRIBOLOGY, 2009, : 44 - +
  • [38] Low Cobalt and Chromium Levels from a Single Metal-on-Metal Total Hip Arthroplasty Implant
    Chen, Antonia F.
    Pigott, Matthew T.
    McClain, Edward J.
    Klatt, Brian A.
    METAL-ON-METAL TOTAL HIP REPLACEMENT DEVICES, 2013, 1560 : 61 - 72
  • [39] Metal-on-metal hip surface replacement THE ROUTINE USE IS NOT JUSTIFIED
    Dunbar, M. J.
    Prasad, V.
    Weerts, B.
    Richardson, G.
    BONE & JOINT JOURNAL, 2014, 96B : 17 - 21
  • [40] A novel approach to the estimation and application of the wear coefficient of metal-on-metal hip implants
    Di Puccio, Francesca
    Mattei, Lorenza
    TRIBOLOGY INTERNATIONAL, 2015, 83 : 69 - 76