Comparison of three two-dimensional echocardiographic methods of assessing left ventricular size in Doberman Pinschers*

被引:2
|
作者
Kruckman, L. [1 ]
Fries, R. C. [1 ]
Kadotani, S. [1 ]
Stack, J. P. [1 ]
Wallace, L. G. [1 ]
机构
[1] Univ Illinois, Dept Vet Clin Med, 1008 W Hazelwood Dr, Urbana, IL 61801 USA
关键词
Cardiovascular; Ultrasound; Canine; Anatomic M-mode; M-MODE ECHOCARDIOGRAPHY; DILATED CARDIOMYOPATHY; EFFICACY;
D O I
10.1016/j.jvc.2021.05.011
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction: Compare three methods of obtaining linear left ventricular dimensions within the same Doberman Pinscher (DP). Animals: One hundred and thirty-nine client-owned DP. Materials and Methods: Linear left ventricular dimensions were measured using two-dimensional short-axis (Sx-2D), motion-mode short-axis (Sx-MM), and motionmode long-axis (Lx-MM) methods, then left ventricular volumes were obtained using monoplane Simpson's method of discs (SMOD). A Friedman test with Dunn's multiple comparisons was used to compare differences between methods. Bias and correlation were evaluated via Bland-Altman and Spearman's correlation. Sensitivity and specificity for diagnosing occult dilated cardiomyopathy (DCM) compared to SMOD were determined. Coefficients of variation (CVs) were calculated for intra- and inter-observer measurement variability. Results: There were significant differences between all linear dimensions in diastole and systole. Short-axis 2D measurements had significant bias compared with Sx-MM (diastole +1.19 mm, systole +1.65 mm) and Lx-MM (diastole +4.36 mm, systole +3.87 mm) as did Sx-MM compared with Lx-MM (diastole +3.17 mm, systole +2.22 mm). All linear dimensions had a moderate positive correlation with SMOD. The sensitivity and specificity of linear measurements to detect DCM were: Sx-2D (sensitivity 72.0%, specificity 88.5%), Sx-MM (sensitivity 52.0%, specificity 92.0%), and Lx-MM (sensitivity 37.5%, specificity 99.1%). All methods had acceptably low CV for intra-and inter-observer measurement variability. Conclusions: Results of this study suggest that linear measurements are repeatable and correlate with reference standard; however, there is a significant bias between measurements, and they should not be used interchangeably. 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 50 条
  • [21] Two-dimensional echocardiographic estimates of left atrial function in healthy dogs and dogs with myxomatous mitral valve disease
    Dickson, David
    Caivano, Domenico
    Matos, Jose Novo
    Summerfield, Nuala
    Rishniw, Mark
    JOURNAL OF VETERINARY CARDIOLOGY, 2017, 19 (06) : 469 - 479
  • [22] On the differences between two-dimensional and three-dimensional simulations for assessing elastographic image quality: A simulation study
    Patil, Abhay V.
    Krouskop, Thomas A.
    Ophir, Jonathan
    Srinivasan, Seshadri
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (07) : 1129 - 1138
  • [23] Two-dimensional echocardiographic right heart ratios for assessment of right heart size in dogs: Reference intervals and reproducibility
    Sankisov, Jacqueline N.
    Visser, Lance C.
    Davis, Kate E.
    Boon, June A.
    Ross, Evan S.
    Laws, Abigail C.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2024, : 3005 - 3015
  • [24] Real Time Three-Dimensional Echocardiographic Assessment of Left Ventricular Regional Systolic Function and Dyssynchrony in Patients with Dilated Cardiomyopathy
    Mu, Yuming
    Chen, Lu
    Tang, Qi
    Ayoufu, Guligena
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (04): : 415 - 420
  • [25] Is right ventricular systolic function reduced after cardiac surgery? A two- and three-dimensional echocardiographic study
    Tamborini, Gloria
    Muratori, Manuela
    Brusoni, Denise
    Celeste, Fabrizio
    Maffessanti, Francesco
    Caiani, Enrico G.
    Alamanni, Francesco
    Pepi, Mauro
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (05): : 630 - 634
  • [26] Comparison of left ventricular ejection fraction values obtained using invasive contrast left ventriculography, two-dimensional echocardiography, and gated single-photon emission computed tomography
    Garg, Nadish
    Dresser, Thomas
    Aggarwal, Kul
    Gupta, Vishal
    Mittal, Mayank K.
    Alpert, Martin A.
    SAGE OPEN MEDICINE, 2016, 4
  • [27] Comparison between three-dimensional volume-selective turbo spin-echo Imaging and two-dimensional ultrasound for assessing carotid artery structure and function
    Crowe, LA
    Ariff, B
    Keegan, J
    Mohiaddin, RH
    Yang, GZ
    Hughes, AD
    Thom, SAM
    Firmin, DN
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) : 282 - 289
  • [28] Prevalence of Left Ventricular Dyssynchrony in Patients with Congenital Atrioventricular Block and Long-Term Pacing: A Three-Dimensional Echocardiographic Study
    Guerra, Vitor Coimbra
    Martins, Luciana de Menezes
    Oliveira, Roberto Marcio
    da Silva, Katia Regina
    Binotto, Maria Angelica
    Tsutsui, Jeane M.
    Kallil, Roberto
    Costa, Roberto
    Mathias, Wilson, Jr.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (09): : 1400 - 1406
  • [29] Real-time two-dimensional and three-dimensional echocardiographic imaging of the thoracic spinal cord: a possible new window into the central neuraxis
    Feinglass, Neil G.
    Clendenen, Steven R.
    Shine, Timothy S. J.
    Martin, Archer K.
    Greengrass, Roy A.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (01) : 121 - 125
  • [30] Assessment of left ventricular function by two-dimensional speckle-tracking echocardiography in small breed dogs with hyperadrenocorticism
    Hung-Yin Chen
    Yu-Hsin Lien
    Hui-Pi Huang
    Acta Veterinaria Scandinavica, 56