14-pixel, multiplexed array of gamma-ray microcalorimeters with 47 eV energy resolution at 103 keV

被引:60
作者
Doriese, W. B.
Ullom, J. N.
Beall, J. A.
Duncan, W. D.
Ferreira, L.
Hilton, G. C.
Horansky, R. D.
Irwin, K. D.
Mates, J. A. B.
Reintsema, C. D.
Vale, L. R.
Xu, Y.
Zink, B. L.
Rabin, M. W.
Hoover, A. S.
Rudy, C. R.
Vo, D. T.
机构
[1] Natl Inst Stand & Technol, Boulder, CO 80305 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
关键词
D O I
10.1063/1.2738371
中图分类号
O59 [应用物理学];
学科分类号
摘要
The authors present a prototype for a high-energy-resolution, high-count-rate, gamma-ray spectrometer intended for nuclear forensics and international nuclear safeguards. The prototype spectrometer is an array of 14 transition-edge-sensor microcalorimeters with an average energy resolution of 47 eV (full width at half maximum) at 103 keV. The resolution of the best pixel is 25 eV. A cryogenic, time-division multiplexer reads out the array. Several important topics related to microcalorimeter arrays are discussed, including cross-talk, the uniformity of detector bias conditions, fabrication of the arrays, and the multiplexed readout. The measurements and calculations demonstrate that a kilopixel array of high-resolution microcalorimeters is feasible. (C) 2007 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 12 条
[1]   Superconducting multiplexer for arrays of transition edge sensors [J].
Chervenak, JA ;
Irwin, KD ;
Grossman, EN ;
Martinis, JM ;
Reintsema, CD ;
Huber, ME .
APPLIED PHYSICS LETTERS, 1999, 74 (26) :4043-4045
[2]   High-resolution operation of frequency-multiplexed transition-edge photon sensors [J].
Cunningham, MF ;
Ullom, JN ;
Miyazaki, T ;
Labov, SE ;
Clarke, J ;
Lanting, TM ;
Lee, AT ;
Richards, PL ;
Yoon, J ;
Spieler, H .
APPLIED PHYSICS LETTERS, 2002, 81 (01) :159-161
[3]   Time-division superconducting quantum interference device multiplexer for transition-edge sensors [J].
de Korte, PAJ ;
Beyer, J ;
Deiker, S ;
Hilton, GC ;
Irwin, KD ;
MacIntosh, M ;
Nam, SW ;
Reintsema, CD ;
Vale, LR ;
Huber, ME .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (08) :3807-3815
[4]   Progress toward kilopixel arrays: 3.8 eV microcalorimeter resolution in 8-channel SQUID multiplexer [J].
Doriese, WB ;
Beall, JA ;
Duncan, WD ;
Ferreira, L ;
Hilton, GC ;
Irwin, KD ;
Reintsema, CD ;
Ullom, JN ;
Vale, LR ;
Xu, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02) :808-810
[5]   Calculation of Tc in a normal-superconductor bilayer using the microscopic-based Usadel theory [J].
Martinis, JM ;
Hilton, GC ;
Irwin, KD ;
Wollman, DA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) :23-27
[6]  
OSHIMA T, 2006, UNPUB 3 INT WORKSH T
[7]   Prototype system for superconducting quantum interference device multiplexing of large-format transition-edge sensor arrays [J].
Reintsema, CD ;
Beyer, J ;
Nam, SW ;
Deiker, S ;
Hilton, GC ;
Irwin, K ;
Martinis, J ;
Ullom, J ;
Vale, LR ;
Macintosh, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (10) :4500-4508
[8]   SIGNAL-PROCESSING FOR MICROCALORIMETERS [J].
SZYMKOWIAK, AE ;
KELLEY, RL ;
MOSELEY, SH ;
STAHLE, CK .
JOURNAL OF LOW TEMPERATURE PHYSICS, 1993, 93 (3-4) :281-285
[9]   Optimized transition-edge x-ray microcalorimeter with 2.4 eV energy resolution at 5.9 keV [J].
Ullom, JN ;
Beall, JA ;
Doriese, WB ;
Duncan, WD ;
Ferreira, L ;
Hilton, GC ;
Irwin, KD ;
Reintsema, CD ;
Vale, LR .
APPLIED PHYSICS LETTERS, 2005, 87 (19) :1-3
[10]   Characterization and reduction of unexplained noise in superconducting transition-edge sensors [J].
Ullom, JN ;
Doriese, WB ;
Hilton, GC ;
Beall, JA ;
Deiker, S ;
Duncan, WD ;
Ferreira, L ;
Irwin, KD ;
Reintsema, CD ;
Vale, LR .
APPLIED PHYSICS LETTERS, 2004, 84 (21) :4206-4208