Bite Force Transducers and Measurement Devices

被引:35
作者
Gu, Yingzhi [1 ]
Bai, Yuxing [1 ]
Xie, Xianju [1 ]
机构
[1] Capital Med Univ, Beijing Stomatol Hosp, Dept Orthodont, Beijing, Peoples R China
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2021年 / 9卷
基金
国家重点研发计划;
关键词
bite force; force transducer; masticatory system; bite force device; force measurement; OVERDENTURE; CHILDREN; MUSCLE; SENSOR; SIGNS; LIP;
D O I
10.3389/fbioe.2021.665081
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In dental research, bite force has become an important curative effect evaluation index for tooth restoration, periodontal treatment, and orthodontic treatment. Bite force is an important parameter to evaluate the efficacy of the masticatory system. Physicians obtain the therapeutic basis for occlusal adjustment by measuring the bite force and the dynamic changes in occlusal contact at different stages of treatment and objectively evaluate the therapeutic effect. At present, many devices are used to record the bite force. Most of these devices use force transducers to detect bite force, such as strain gauge transducers, piezoresistive transducers, piezoelectric transducers, optical fiber transducers, and pressure-sensitive films. This article summarizes the various equipment used to record bite force, related materials and the characteristics of this equipment. It provides a reference for physicians to make choices during the clinical process and at the same time provides a basis for the development of new occlusal force measurement materials.
引用
收藏
页数:9
相关论文
共 67 条
  • [1] PVDF-BaTiO3 Nanocomposite Inkjet Inks with Enhanced β-Phase Crystallinity for Printed Electronics
    Abdolmaleki, Hamed
    Agarwala, Shweta
    [J]. POLYMERS, 2020, 12 (10) : 1 - 12
  • [2] Maximum bite force following unilateral implant-supported prosthetic treatment: within-subject comparison to opposite dentate side
    AL-Omiri, M. K.
    Sghaireen, M. G.
    Alhijawi, M. M.
    Alzoubi, I. A.
    Lynch, C. D.
    Lynch, E.
    [J]. JOURNAL OF ORAL REHABILITATION, 2014, 41 (08) : 624 - 629
  • [3] Maximum voluntary molar bite force in subjects with malocclusion: multifactor analysis
    Alam, Mohammad Khursheed
    Alfawzan, Ahmed Ali
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (10)
  • [4] Bite Force and Occlusal Patterns in the Mixed Dentition of Children with Down Syndrome
    Assery, Mansour K.
    Albusaily, Hanaa S.
    Pani, Sharat C.
    Aldossary, Mohammed S.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (06): : 472 - 478
  • [5] Athavale ON, 2020, IEEE ENG MED BIO, P4204, DOI 10.1109/EMBC44109.2020.9175843
  • [6] Bakke M., 2006, SEMIN ORTHOD, V12, P120, DOI [DOI 10.1053/J.SODO.2006.01.005, 10.1053/j.sodo.2006.01.005]
  • [7] Bavia Paula Furlan, 2016, Braz. Dent. J., V27, P619, DOI 10.1590/0103-6440201600708
  • [8] Effect of peri-implant bone resorption on mechanical stress in the implant body: In vivo measured load-based finite element analysis
    Bing, Liu
    Mito, Takehiko
    Yoda, Nobuhiro
    Sato, Emika
    Shigemitsu, Ryuji
    Han, Jian-Min
    Sasaki, Keiichi
    [J]. JOURNAL OF ORAL REHABILITATION, 2020, 47 (12) : 1566 - 1573
  • [9] Braun S, 1996, ANGLE ORTHOD, V66, P261
  • [10] An ultrahigh resolution pressure sensor based on percolative metal nanoparticle arrays
    Chen, Minrui
    Luo, Weifeng
    Xu, Zhongqi
    Zhang, Xueping
    Xie, Bo
    Wang, Guanghou
    Han, Min
    [J]. NATURE COMMUNICATIONS, 2019, 10 (1)