Sensitive LC-MS-MS method for the determination of tiopronin in human plasma

被引:7
作者
Jiang, Bo [1 ]
Xu, Yu [1 ]
Xu, Fang [1 ]
Sun, Junjie [1 ]
Li, Na [1 ]
Luo, Yanan [1 ]
Guo, Qingxiang [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Peoples R China
关键词
tiopronin; LC-MS-MS; pharmacokinetic application; human plasma; PERFORMANCE LIQUID-CHROMATOGRAPHY; FLOW-INJECTION; THIOL-GROUP; DERIVATIZATION REAGENT; HUMAN URINE; PENICILLAMINE; ACRYLATE; BLOOD; ACID;
D O I
10.1002/bmc.1342
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A highly selective and sensitive LC-MS-MS method was developed and validated to quantify tiopronin in human plasma, using fudosteine as the internal standard (IS)L-Cysteine and 1,4-dithiothreitol (DTT) were used as the reducer and the stabilizer to release and stabilify tiopronin from a dimmer and mix forms with endogenous thiols in the treatment of plasma samples. After a simple liquid-liquid extraction with ethyl acetate in acidic condition, the post-treatment samples were analyzed on a C-18 column interfaced with a triple-quadruple tandem mass spectrometer using negative electrospray ionization. Methanol and water (40:60, v/v) were used as the isocratic mobile phase, with 0.2% formic acid and 1.0 mm tris (hydroxymethyl) aminomethane (Tris) in water. The method was validated to demonstrate the specificity, lower limit of quantification, accuracy and precision of measurements. The assay was linear over the concentration range 0.078-10 mu g/mL. The correlation coefficients for the calibration curves ranged from 0.9980 to 0.9990. The intra- and inter-day precisions, calculated from quality control samples, were not more than 10.49%. The method was employed in a pharmacokinetic study after oral administration of 200 mg tiopronin tablets to 24 healthy volunteers. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:655 / 662
页数:8
相关论文
共 15 条
[1]  
FERRACCIOLI GF, 1986, CLIN EXP RHEUMATOL, V4, P9
[2]   PHARMACOKINETICS OF TIOPRONIN AFTER REPEATED ORAL-ADMINISTRATION IN RHEUMATOID-ARTHRITIS [J].
GILLET, P ;
GAVRILOFF, C ;
HERCELIN, B ;
SALLES, MF ;
NICOLAS, A ;
NETTER, P .
FUNDAMENTAL & CLINICAL PHARMACOLOGY, 1995, 9 (02) :205-206
[3]   Reverse-phase high performance liquid chromatography for the determination of tiopronin in human plasma after derivatization with p-bromophenacyl bromide [J].
Huang, TM ;
Yang, B ;
Yu, YJ ;
Zheng, XW ;
Duan, GL .
ANALYTICA CHIMICA ACTA, 2006, 565 (02) :178-182
[4]   EFFECT OF TIOPRONIN ON SENILE CATARACTS - A DOUBLE-BLIND CLINICAL-STUDY [J].
ICHIKAWA, H ;
IMAIZUMI, K ;
TAZAWA, Y ;
OBARA, Y ;
ISHIKAWA, Y ;
TOBARI, I ;
TANABE, Y .
OPHTHALMOLOGICA, 1980, 180 (05) :293-298
[5]   Simultaneous determination of tiopronin and D-penicillamine in human urine by liquid chromatography with ultraviolet detection [J].
Kusmierek, Krzysztof ;
Bald, Edward .
ANALYTICA CHIMICA ACTA, 2007, 590 (01) :132-137
[6]   CLINICAL COURSE AND CYSTINE STONE FORMATION DURING TIOPRONIN TREATMENT [J].
LINDELL, A ;
DENNEBERG, T ;
HELLGREN, E ;
JEPPSSON, JO ;
TISELIUS, HG .
UROLOGICAL RESEARCH, 1995, 23 (02) :111-117
[7]   Determination of total tiopronin in human plasma by LC-ESI-MS using tris (2-carboxy-ethyl) phosphine as reducing reagent and methyl acrylate as derivatization reagent for the thiol group [J].
Liu, Jianfang ;
Wu, Honghai ;
Hou, Yanning .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01) :153-157
[8]   A simple and sensitive chemiluminescence method for the determination of tiopronin for a pharmaceutical formulation [J].
Lu, JZ ;
Lau, CW ;
Yagisawa, S ;
Ohta, K ;
Kai, MS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) :1033-1038
[9]   High-performance liquid chromatography-electronspray ionization mass spectrometry for determination of tiopronin in human plasma [J].
Ma, JY ;
Gu, YL ;
Chen, B ;
Yao, SZ ;
Chen, ZN .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1113 (1-2) :55-59
[10]   GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC DETERMINATION OF TIOPRONIN IN HUMAN BLOOD USING ACRYLIC-ACID ESTERS AS A DERIVATIZATION REAGENT FOR THE THIOL-GROUP [J].
MATSUURA, K ;
TAKASHINA, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 616 (02) :229-234