An innovative and simple method, clinically comparable to high-definition optical coherence tomography in quantifying posterior segment lesions in the retina
被引:0
作者:
Koshy, Shaji P.
论文数: 0引用数: 0
h-index: 0
机构:
Believers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, IndiaBelievers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, India
Koshy, Shaji P.
[1
]
Varghese, Leena Mariyam
论文数: 0引用数: 0
h-index: 0
机构:
Believers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, IndiaBelievers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, India
Varghese, Leena Mariyam
[1
]
Thomas, Satish
论文数: 0引用数: 0
h-index: 0
机构:
Believers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, IndiaBelievers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, India
Thomas, Satish
[1
]
Thomas, Pramod
论文数: 0引用数: 0
h-index: 0
机构:
Believers Church Med Coll Hosp, Dept Community Med, Thiruvalla, Kerala, IndiaBelievers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, India
Thomas, Pramod
[2
]
机构:
[1] Believers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, India
[2] Believers Church Med Coll Hosp, Dept Community Med, Thiruvalla, Kerala, India
Purpose: To introduce a simple and inexpensive method using a fundus contact lens and a reticle, to measure retinal lesions comparing it with values obtained with high- definition optical coherence tomography (HD-OCT). This study considers optic disc as the object for comparison. Methods: Patients underwent routine ophthalmologic examination and their horizontal optic disc diameter was measured, both with the reticle and OCT. For measurement with reticle a simple equation was deduced, x = 0.7y, where x corresponds to the actual image size and y to the reticle scale reading in millimeters. Results: An aggregate of 127 eyes of 75 patients were dilated and examined. The calculated mean diameter according to OCT was 1.639 mm (standard deviation = 0.179) and that assenting to reticle was 1.713 mm (standard deviation = 0.175), with a difference in mean being 0.089 mm. Conclusion: Values obtained by this new method was found to be comparable with the OCT values for retinal measurements, useful for ophthalmologists who cannot afford expensive and sophisticated machines.
机构:
Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
Hoffmann, Esther M.
Zangwill, Linda M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
Zangwill, Linda M.
Crowston, Jonathan G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
Crowston, Jonathan G.
Weinreb, Robert N.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
机构:
Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
Hoffmann, Esther M.
Zangwill, Linda M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
Zangwill, Linda M.
Crowston, Jonathan G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
Crowston, Jonathan G.
Weinreb, Robert N.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA