An innovative and simple method, clinically comparable to high-definition optical coherence tomography in quantifying posterior segment lesions in the retina

被引:0
作者
Koshy, Shaji P. [1 ]
Varghese, Leena Mariyam [1 ]
Thomas, Satish [1 ]
Thomas, Pramod [2 ]
机构
[1] Believers Church Med Coll Hosp, Dept Ophthalmol, Thiruvalla 689103, Kerala, India
[2] Believers Church Med Coll Hosp, Dept Community Med, Thiruvalla, Kerala, India
关键词
HD-OCT; OMRA-S Mainster focal/grid lens; optic disc diameter; reticle;
D O I
10.4103/ijo.IJO_1188_19
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To introduce a simple and inexpensive method using a fundus contact lens and a reticle, to measure retinal lesions comparing it with values obtained with high- definition optical coherence tomography (HD-OCT). This study considers optic disc as the object for comparison. Methods: Patients underwent routine ophthalmologic examination and their horizontal optic disc diameter was measured, both with the reticle and OCT. For measurement with reticle a simple equation was deduced, x = 0.7y, where x corresponds to the actual image size and y to the reticle scale reading in millimeters. Results: An aggregate of 127 eyes of 75 patients were dilated and examined. The calculated mean diameter according to OCT was 1.639 mm (standard deviation = 0.179) and that assenting to reticle was 1.713 mm (standard deviation = 0.175), with a difference in mean being 0.089 mm. Conclusion: Values obtained by this new method was found to be comparable with the OCT values for retinal measurements, useful for ophthalmologists who cannot afford expensive and sophisticated machines.
引用
收藏
页码:875 / 879
页数:5
相关论文
共 27 条
  • [1] Optic disc measurements with the 78 diopter lens, Zeiss 4-mirror contact lens and computerized image analysing system
    Akman, A
    Oram, O
    Aydin, P
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 1998, 8 (01) : 22 - 27
  • [2] Alfred C, 1921, AJO, V4, P28
  • [3] ARNOLD JV, 1993, INVEST OPHTH VIS SCI, V34, P2576
  • [4] Assessment of the Optic Disc Morphology Using Spectral-Domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy
    Calvo, Pilar
    Ferreras, Antonio
    Abadia, Beatriz
    Ara, Mirian
    Figus, Michele
    Pablo, Luis E.
    Frezzotti, Paolo
    [J]. BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [5] Optic disc topography of normal Indian eyes: An assessment using optical coherence tomography
    Dacosta, Shaun
    Bilal, Sheena
    Rajendran, Babu
    Janakiraman, P.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2008, 56 (02) : 99 - 102
  • [6] Role of optic nerve imaging in glaucoma clinical practice and clinical trials
    Greenfield, David S.
    Weinreb, Robert N.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (04) : 598 - 603
  • [7] Gross P G, 1995, J Glaucoma, V4, P314
  • [8] Factors Affecting Cirrus-HD OCT Optic Disc Scan Quality: A Review with Case Examples
    Hardin, Joshua S.
    Taibbi, Giovanni
    Nelson, Seth C.
    Chao, Diana
    Vizzeri, Gianmarco
    [J]. JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [9] Agreement among 3 optical imaging methods for the assessment of optic disc topography
    Hoffmann, EM
    Bowd, C
    Medeiros, FA
    Boden, C
    Grus, FH
    Bourne, RR
    Zangwill, LM
    Weinreb, RN
    [J]. OPHTHALMOLOGY, 2005, 112 (12) : 2149 - 2156
  • [10] Optic disk size and glaucoma
    Hoffmann, Esther M.
    Zangwill, Linda M.
    Crowston, Jonathan G.
    Weinreb, Robert N.
    [J]. SURVEY OF OPHTHALMOLOGY, 2007, 52 (01) : 32 - 49