Technical pearls in total hip arthroplasty

被引:0
作者
Mulier, M. [1 ]
Raaijmaakers, M. [1 ]
Van den Bekerom, M. [2 ]
机构
[1] Catholic Univ Louvain, Dept Orthoped Surg, Univ Hosp Pellenberg, B-3000 Louvain, Belgium
[2] Univ Amsterdam, Acad Med Ctr, Dept Orthoped Surg, NL-1105 AZ Amsterdam, Netherlands
关键词
Arthroplasty; replacement; hip; Hip joints; Radiography; FEMORAL-HEAD ALLOGRAFTS; FATIGUE FRACTURES; REPLACEMENT; COMPONENT; PROSTHESIS; FIXATION; RECONSTRUCTIONS; DENSITOMETRY; OSTEOLYSIS; OPERATION;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Total hip arthroplasty (THA) has had a big impact on the quality of life of millions of patients. Primary THA has a very high success rate and implant survival time of more than 30 years have been reported. However, because of the high number of procedures performed, the small percentage of patients requiring a revision surgery still represent a large number of patients. Templating by means of radiography of hip joints with a defectuous implant-bone fixation can be hindered by the presence of cement and/or by reduced bone quality. Selection of the implant should be guided by the altered anatomy of the femur and/or acetabulum. In some cases the commercially available implants do not allow fixation and restoration of the joint mechanics. To adapt the implants to the patient's anatomy custom production can be envisioned. Custom made stem implants have been used since 1987 in our centre. Adaptations have been made and tests for evaluating implant stability have been evaluated. Also a new technique that has the objective to help the surgeon in determing the correct stem insertion during surgery has shown promissing results. Several changes in design of the acetabular component have progressively improved the cup stability, even in revision surgery. But a small number of patients present with pelvic and acetabular bone defects that cannot be bridged by the standard cup implants. Also custom made acetabular implants are progressively been used and the new production techniques offer promissing perspectives.
引用
收藏
页码:27 / 41
页数:15
相关论文
共 74 条
[1]   Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems 37 patients followed for 3 years [J].
Albanese, Carlina V. ;
Santori, Francesco S. ;
Pavan, Laura ;
Learmonth, Ian D. ;
Passariello, Roberto .
ACTA ORTHOPAEDICA, 2009, 80 (03) :291-297
[2]   Eleven years of experience with metal-on-metal hybrid hip resurfacing - A review of 1000 Conserve Plus [J].
Amstutz, Harlan C. ;
Le Duff, Michel J. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (06) :36-43
[3]  
[Anonymous], J ARTHROPLASTY
[4]   Femoral revision - Distal fixation with fluted, tapered grit-blasted stems [J].
Berry, DJ .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :142-146
[5]  
BIAU DJ, 2009, CLIN ORTHOP RELAT RE
[6]  
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[7]   Blinding was judged more difficult to achieve and maintain in nonpharmacologic than pharmacologic trials [J].
Boutron, I ;
Tubach, F ;
Giraudeau, B ;
Ravaud, P .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2004, 57 (06) :543-550
[8]  
BRAGDON C, 2004, EVALUATIONS METHODS
[9]   Comparison of two digital radio stereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom [J].
Bragdon, CR ;
Estok, DM ;
Malchau, H ;
Kärrholm, J ;
Yuan, XH ;
Bourne, R ;
Veldhoven, J ;
Harris, WH .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (03) :659-664
[10]  
BRAND RA, 1985, CLIN ORTHOP RELAT R, P237