Microcirculation in single and multiple-based perforator flaps in an experimental model of

被引:6
作者
Tonseth, Kim A. [1 ]
Tindholdt, Tyge T. [1 ]
机构
[1] Rikshosp Univ Hosp, Dept Plast Surg, NO-0027 Oslo, Norway
来源
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY | 2007年 / 41卷 / 02期
关键词
rat; perforator; deep inferior epigastric perforator (DIEP); microcirculation; laser Doppler perfusion imaging (LDPI);
D O I
10.1080/02844310601159709
中图分类号
R61 [外科手术学];
学科分类号
摘要
Our aim was to evaluate the effect of single and multiple-based perforator flaps on the microcirculation in rats. Two symmetrical abdominal flaps were raised around the midline in 17 rats, and sutured into their original positions after dissection. All major perforators in the flap were left intact on one side, and on the opposite side only one perforator was retained. The microcirculation in the flaps was measured with laser Doppler perfusion imaging at different time intervals. Before dissection of the flap the mean (SD) microcirculation was 5.5 (1.6) units in the multiple-based perforator flap and 5.5 (1.4) in the single-based perforator flap. Within the first two hours after the flap had been raised the highest microcirculation was found after 30 minutes with 7.3 (1.3) units in the multiple-based perforator flap compared with 6.5 (1.4) units in the single-based perforator flap (p = 0.002). We conclude that the microcirculation in the single-based perforator flap was not reduced after dissection. However, a reactive hyperaemic response was found only in the multiple-based perforator flap.
引用
收藏
页码:49 / 52
页数:4
相关论文
共 10 条
  • [1] DEEP INFERIOR EPIGASTRIC PERFORATOR FLAP FOR BREAST RECONSTRUCTION
    ALLEN, RJ
    TREECE, P
    [J]. ANNALS OF PLASTIC SURGERY, 1994, 32 (01) : 32 - 38
  • [2] Aydin MA, 2003, J RECONSTR MICROSURG, V19, P187
  • [3] REFINEMENTS IN FREE-FLAP BREAST RECONSTRUCTION - THE FREE BILATERAL DEEP INFERIOR EPIGASTRIC PERFORATOR FLAP ANASTOMOSED TO THE INTERNAL MAMMARY ARTERY
    BLONDEEL, PN
    BOECKX, WD
    [J]. BRITISH JOURNAL OF PLASTIC SURGERY, 1994, 47 (07): : 495 - 501
  • [4] A 10-year retrospective review of 758 DIEP flaps for breast reconstruction
    Gill, PS
    Hunt, JP
    Guerra, AB
    Dellacroce, FJ
    Sullivan, SK
    Boraski, J
    Metzinger, SE
    Dupin, CL
    Allen, RJ
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 113 (04) : 1153 - 1160
  • [5] Comparison of TRAM and DIEP flap physiology in a rat model
    Hallock, GG
    Rice, DC
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2004, 114 (05) : 1179 - 1184
  • [6] FREE ABDOMINOPLASTY FLAP AND ITS USE IN BREAST RECONSTRUCTION - EXPERIMENTAL-STUDY AND CLINICAL CASE-REPORT
    HOLMSTROM, H
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1979, 13 (03): : 423 - 427
  • [7] FREE THIN PARAUMBILICAL PERFORATOR-BASED FLAPS
    KOSHIMA, I
    MORIGUCHI, T
    SOEDA, S
    TANAKA, H
    UMEDA, N
    [J]. ANNALS OF PLASTIC SURGERY, 1992, 29 (01) : 12 - 17
  • [8] NAKAJIMA T, 1978, BRIT J PLAST SURG, V31, P300, DOI 10.1016/S0007-1226(78)90115-7
  • [9] Perforator-based flap in rats:: A new experimental model
    Oksar, HS
    Coskunfirat, OK
    Özgentas, HE
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 108 (01) : 125 - 131
  • [10] NEOVASCULARIZATION OF SKIN FLAPS - ROUTE AND TIMING
    TSUR, H
    DANILLER, A
    STRAUCH, B
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1980, 66 (01) : 85 - 93