Do dose-volume metrics predict pulmonary function changes in lung irradiation?

被引:17
|
作者
Allen, AM [1 ]
Henning, GT [1 ]
Ten Haken, RK [1 ]
Hayman, JA [1 ]
Martel, MK [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 55卷 / 04期
关键词
D O I
10.1016/S0360-3016(02)04288-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To examine the ability of standard dose-volume metrics to predict pulmonary function changes as measured by pulmonary function tests (PFTs) in a group of patients with non-small-cell lung cancer treated with nonconventional beam arrangements on a Phase I dose-escalation study. In addition, we wanted to examine the correlation between these metrics. Methods and Materials: Forty-three patients received a median treatment dose of 76.9 Gy (range 63-102.9). Eight patients also received induction chemotherapy with cisplatin and vinorelbine. They all had pre- and posttreatment PFTs greater than or equal to3 months (median 6.2) after treatment. The volume of normal lung treated to >20 Gy, effective volume, and mean lung dose were calculated for both lungs for all patients. Linear regression analysis was performed to determine whether correlations existed between the metrics and changes in the PFTs. Additionally, the three metrics were compared with each other to assess the degree of intermetric correlation. Results: No correlation was found between the volume of normal lung treated to >20 Gy, effective volume, and mean lung dose and changes in the PFTs. Subgroup analyses of patients without atelectasis before irradiation, Stage I and II disease, or treatment without induction chemotherapy were also performed. Again, no correlation was found between the dose-volume metrics and the PFT changes. The intermetric correlation was good among all three dose-volume metrics. Conclusion: In this relatively small series of patients, dose-volume metrics that correlate with the risk of pneumonitis did not provide a good model to predict early changes in pulmonary function as measured with PFTs. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:921 / 929
页数:9
相关论文
共 50 条
  • [21] Rectum complication following prostate irradiation: dose-volume relationships
    Fiorino, C
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S60 - S60
  • [22] Correlating dose and volume of irradiated lung with pulmonary function tests
    Phillips, TL
    CANCER JOURNAL, 2002, 8 (06): : 438 - 439
  • [23] RADIOTHERAPY DOSE-VOLUME EFFECTS ON SALIVARY GLAND FUNCTION
    Deasy, Joseph O.
    Moiseenko, Vitali
    Marks, Lawrence
    Chao, K. S. Clifford
    Nam, Jiho
    Eisbruch, Avraham
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03): : S58 - S63
  • [24] Evaluation of Dose-Volume Metrics Associated With Local Recurrence After Stereotactic Body Radiation Therapy for Lung Cancer
    Matsuo, Y.
    Shibuya, K.
    Nakamura, M.
    Narabayashi, M.
    Sakanaka, K.
    Ueki, N.
    Mizowaki, T.
    Hiraoka, M.
    JOURNAL OF THORACIC ONCOLOGY, 2010, 5 (12) : S544 - S544
  • [25] Development of the conventional DVH - function dose-volume histograms
    Beijing Shengwu Yixue Gongcheng/Beijing Biomedical Engineering, 1998, 17 (03): : 168 - 172
  • [26] The effect of rectal volume on rectum dose-volume metrics during cervical high dose-rate brachytherapy
    Martos Casado, A.
    Sabater, S.
    Gutierrez-Perez, M.
    Sevillano, M. M.
    Andres, I.
    Berenguer, R.
    Arenas, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S323 - S324
  • [27] LACK OF DOSE-VOLUME PARAMETER TO PREDICT THE DEVELOPMENT OF CHEST WALL PAIN AFTER SBRT FOR LUNG CANCER
    Faria, Sergio
    El Naqa, Issam
    Wang, L. Ming
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S56 - S56
  • [28] Direct optimization of dose-volume histogram metrics in radiation therapy treatment planning
    Zhang, Tianfang
    Bokrantz, Rasmus
    Olsson, Jimmy
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)
  • [29] Incidence of radiation pneumonitis after thoracic irradiation: Dose-volume correlates
    Schallenkamp, John M.
    Miller, Robert C.
    Brinkmann, Debra H.
    Foote, Tyler
    Garces, Yolanda I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (02): : 410 - 416
  • [30] 3-DIMENSIONAL DOSE-VOLUME ANALYSIS OF IRRADIATION OF INTACT BREASTS
    BUCHHOLZ, TA
    GURGOZE, E
    RADIOLOGY, 1995, 197 : 190 - 190