Atrial Fibrillation Detection from Wrist Photoplethysmography Signals Using Smartwatches

被引:87
作者
Bashar, Syed Khairul [1 ]
Han, Dong [1 ]
Hajeb-Mohammadalipour, Shirin [1 ]
Ding, Eric [2 ]
Whitcomb, Cody [2 ]
McManus, David D. [2 ]
Chon, Ki H. [1 ]
机构
[1] Univ Connecticut, Dept Biomed Engn, Storrs, CT 06269 USA
[2] Univ Massachusetts, Sch Med, Div Cardiol, Worcester, MA USA
基金
美国国家科学基金会;
关键词
MOTION ARTIFACT; ALGORITHM; BURDEN; STROKE;
D O I
10.1038/s41598-019-49092-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Detection of atrial fibrillation (AF) from a wrist watch photoplethysmogram (PPG) signal is important because the wrist watch form factor enables long term continuous monitoring of arrhythmia in an easy and non-invasive manner. We have developed a novel method not only to detect AF from a smart wrist watch PPG signal, but also to determine whether the recorded PPG signal is corrupted by motion artifacts or not. We detect motion and noise artifacts based on the accelerometer signal and variable frequency complex demodulation based time-frequency analysis of the PPG signal. After that, we use the root mean square of successive differences and sample entropy, calculated from the beat-to-beat intervals of the PPG signal, to distinguish AF from normal rhythm. We then use a premature atrial contraction detection algorithm to have more accurate AF identification and to reduce false alarms. Two separate datasets have been used in this study to test the efficacy of the proposed method, which shows a combined sensitivity, specificity and accuracy of 98.18%, 97.43% and 97.54% across the datasets.
引用
收藏
页数:10
相关论文
共 25 条
[1]  
Bashar Syed Khairul, 2018, 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), P79, DOI 10.1109/BHI.2018.8333374
[2]   VERB: VFCDM-Based Electrocardiogram Reconstruction and Beat Detection Algorithm [J].
Bashar, Syed Khairul ;
Noh, Yeonsik ;
Walkey, Allan J. ;
McManus, David D. ;
Chon, Ki H. .
IEEE ACCESS, 2019, 7 :13856-13866
[3]   Smartwatch Algorithm for Automated Detection of Atrial Fibrillation [J].
Bumgarner, Joseph M. ;
Lambert, Cameron T. ;
Hussein, Ayman A. ;
Cantillon, Daniel J. ;
Baranowski, Bryan ;
Wolski, Kathy ;
Lindsay, Bruce D. ;
Wazni, Oussama M. ;
Tarakji, Khaldoun G. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (21) :2381-2388
[4]   Arrhythmia Discrimination Using a Smart Phone [J].
Chong, Jo Woon ;
Esa, Nada ;
McManus, David D. ;
Chon, Ki H. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2015, 19 (03) :815-824
[5]   Worldwide Epidemiology of Atrial Fibrillation A Global Burden of Disease 2010 Study [J].
Chugh, Sumeet S. ;
Havmoeller, Rasmus ;
Narayanan, Kumar ;
Singh, David ;
Rienstra, Michiel ;
Benjamin, Emelia J. ;
Gillum, Richard F. ;
Kim, Young-Hoon ;
McAnulty, John H. ;
Zheng, Zhi-Jie ;
Forouzanfar, Mohammad H. ;
Naghavi, Mohsen ;
Mensah, George A. ;
Ezzati, Majid ;
Murray, Christopher J. L. .
CIRCULATION, 2014, 129 (08) :837-847
[6]   A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features [J].
Dao, Duy ;
Salehizadeh, S. M. A. ;
Noh, Yeonsik ;
Chong, Jo Woon ;
Cho, Chae Ho ;
McManus, Dave ;
Darling, Chad E. ;
Mendelson, Yitzhak ;
Chon, Ki H. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (05) :1242-1253
[7]   Automatic Real Time Detection of Atrial Fibrillation [J].
Dash, S. ;
Chon, K. H. ;
Lu, S. ;
Raeder, E. A. .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (09) :1701-1709
[8]  
Ding Eric Y, 2019, JMIR Cardio, V3, pe13850, DOI 10.2196/13850
[9]   The WATCH AF Trial: SmartWATCHes for Detection of Atrial Fibrillation [J].
Doerr, Marcus ;
Nohturfft, Vivien ;
Brasier, Noe ;
Bosshard, Emil ;
Djurdjevic, Aleksandar ;
Gross, Stefan ;
Raichle, Christina J. ;
Rhinisperger, Mattias ;
Stoeckli, Raphael ;
Eckstein, Jens .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (02) :199-208
[10]  
Duverney D, PACING CLIN ELECTROP, V25, P457