Measurement of Total and Compartmental Lung Volume Changes in Newborns by Optoelectronic Plethysmography

被引:40
作者
Dellaca, Raffaele L. [1 ]
Ventura, Maria L. [2 ]
Zannin, Emanuela [1 ]
Natile, Miria [2 ]
Pedotti, Antonio [1 ]
Tagliabue, Paolo [2 ]
机构
[1] Politecn Milan, Dipartimento Bioingn, I-20133 Milan, Italy
[2] S Gerardo Hosp, Neonatol & Neonatal Intens Care Unit, I-20052 Monza, Italy
关键词
RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY; CHEST-WALL MOTION; RIB CAGE; BRONCHOPULMONARY DYSPLASIA; OPTICAL ANALYSIS; INFANTS; SLEEP; MOVEMENT; CHILDREN; SYSTEM;
D O I
10.1203/PDR.0b013e3181c0b184
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The study of respiratory mechanics in infants requires a noninvasive accurate measurement of the lung volume changes (Delta V(L)). Optoelectronic plethysmography (OEP) allows the assessment of Delta V(L) through the measurement of the chest wall surface motion and it has been proved to be accurate in adults. The aim of this study was to apply OEP to newborns and to validate it by comparison to pneumotachography. Twenty term and preterm newborns (GA = 34 +/- 5 wk) in stable condition were studied during 1 to 2 min periods of quiet breathing in supine position. Airway opening flow was measured by applying a facemask connected to a pneumotachograph (PNT) and integrated to provide the Delta V(L). Chest wall volume changes were simultaneously measured by OEP. The tidal volume values measured by pneumotachography and by OEP were compared for each breath. A total of 771 breaths from all patients were considered. Bland-Altmann analysis showed a mean difference of -0.08 mL and a limit of agreement ranging from -2.98 to 2.83 mL. Linear regression analysis demonstrated good correlation between the two techniques (r(2) = 0.95, q = 1.00 mL, m = 0.96). OEP provides accurate measurements of Delta V(L) in newborns and may be useful to study respiratory mechanics and breathing patterns during spontaneous breathing and mechanical ventilation. (Pediatr Res 67: 11-16, 2010)
引用
收藏
页码:11 / 16
页数:6
相关论文
共 24 条
[21]   Evaluation of respiratory inductive plethysmography in controlled ventilation - Measurement of tidal volume and PEEP-induced changes of end-expiratory lung volume [J].
Neumann, P ;
Zinserling, J ;
Haase, C ;
Sydow, M ;
Burchardi, H .
CHEST, 1998, 113 (02) :443-451
[22]   Chest wall motion in preterm infants using respiratory inductive plethysmography [J].
Warren, RH ;
Horan, SM ;
Robertson, PK .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (10) :2295-2300
[23]   BREATHING PATTERNS IN INFANTS UTILIZING RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY [J].
WARREN, RH ;
ALDERSON, SH .
CHEST, 1986, 89 (05) :717-722
[24]   INDUCTANCE PLETHYSMOGRAPH MEASUREMENT OF CPAP-INDUCED CHANGES IN END-EXPIRATORY LUNG-VOLUME [J].
WERCHOWSKI, JL ;
SANDERS, MH ;
COSTANTINO, JP ;
SCIURBA, FC ;
ROGERS, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 1990, 68 (04) :1732-1738