Failure analysis of ammonium chloride salt coagulation corrosion of U-tube heat exchanger in diesel hydrogenation unit

被引:11
|
作者
Ou, Guofu [1 ]
Gu, Youjie [1 ]
Yu, Chenyang [2 ]
Jin, Haozhe [2 ]
机构
[1] Changzhou Univ, Inst Flow Induced Corros & Intelligent Prevent & C, Changzhou 213164, Peoples R China
[2] Zhejiang Sci Tech Univ, Inst Flow Induced Corros, Hangzhou 310018, Peoples R China
基金
中国国家自然科学基金;
关键词
Hydrogenation heat exchanger; Reaction effluent; Ammonium chloride salt coagulation; Flow deposition; Under-deposit corrosion;
D O I
10.1016/j.engfailanal.2022.106264
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Diesel hydrogenation unit is an important equipment for processing inferior oil in petroleum refining enterprises. Among them, the U-tube heat exchanger has been in high temperature and corrosive environment containing chlorine for a long time. Serious problem of tube bundle corrosion failure caused by ammonium chloride salt deposit. Anatomy of the diesel hydrogenation heat exchanger showed that the leakage part mainly appeared in the outermost bundle of the heat exchanger tube near the exit section, and the local area showed a large area of gully damage. Metallographic and XRD results show that the failure tube bundle material does not have manufacturing defects, and the corrosion location scale contains NH4Cl and iron oxides. The process flow analysis based on PR-NRTL model showed that the heat exchanger was in the NH4Cl crystallization temperature range, and the crystallization temperature increased with the increase of N and Cl contents in raw materials. Fluid simulation analysis of inlet tube box and single U-tube is carried out by using component transport equation and condensation model. Computational fluid dynamics (CFD) results indicate that there is a low velocity zone with high volume fraction of gas phase in the tube box. The higher gas volume fraction results in the formation of more NH4Cl particles into the U-tube bundle during heat transfer cooling. With the decrease of temperature, liquid water content in U-tube increases gradually and mainly distributes at both sides and bottom of tube bundle. The gas phase gradually fills the top of the tube bundle, and the oil and gas stratification becomes more obvious. The mass transfer rate and corrosion rate were the highest at the bottom and both sides of the tube bundle. With the temperature decreases, the NH4Cl particles generated in the tube continue to increase. The particles were deposited at 2000-3000 mm near the outlet section of the U-tube tube. NH4Cl particles absorbed liquid water, resulting in under-deposit corrosion of the tube bundle, and eventually led to the thinning and leakage of the heat exchanger tube bundle.
引用
收藏
页数:15
相关论文
共 39 条
  • [21] Failure analysis of crevice corrosion on 304 stainless steel tube heat exchanger
    Dong, Chen
    Qu, Shen
    Fu, Chang-ming
    Zhang, Zhe-feng
    JOURNAL OF IRON AND STEEL RESEARCH INTERNATIONAL, 2023, 30 (08) : 1490 - 1498
  • [22] Failure analysis of crevice corrosion on 304 stainless steel tube heat exchanger
    Chen Dong
    Shen Qu
    Chang-ming Fu
    Zhe-feng Zhang
    Journal of Iron and Steel Research International, 2023, 30 : 1490 - 1498
  • [23] Temperature field and stress field analysis of molten salt U-tube heat exchanger based on fluid-thermal-solid coupling method
    Chen Y.
    Tian J.
    Ding M.
    Zou Y.
    Wang N.
    He Jishu/Nuclear Techniques, 2023, 46 (01):
  • [24] Performance analysis of a solar-assisted ground source heat pump with a single vertical U-tube ground heat exchanger
    Adebayo, Philip
    Shor, Roman
    Mohamad, Abdulmajeed
    Wemhoner, Carsten
    Mwesigye, Aggrey
    APPLIED THERMAL ENGINEERING, 2024, 257
  • [25] Heat transfer mechanism and parameter analysis of the U-tube borehole ground heat exchanger of middle-shallow geothermal energy
    Zhang, Wenke
    Gao, Yuxue
    Yao, Haiqing
    Li, Wenjing
    Cui, Ping
    Yu, Mingzhi
    Zhou, Shiyu
    JOURNAL OF BUILDING ENGINEERING, 2025, 102
  • [26] Light-Weight Design of the Tubesheet of a High Pressure U-Tube Heat Exchanger Based on Finite Element Analysis
    Liu, J. Y.
    Qian, C. F.
    Li, H. F.
    PRESSURE VESSEL TECHNOLOGY: PREPARING FOR THE FUTURE, 2015, 130 : 275 - 285
  • [27] Transient heat transfer simulation, analysis and thermal performance study of double U-tube borehole heat exchanger based on numerical heat transfer model
    Kerme, Esa Dube
    Fung, Alan S.
    APPLIED THERMAL ENGINEERING, 2020, 173
  • [28] Efficiency analysis of utilizing phase change materials as grout for a vertical U-tube heat exchanger coupled ground source heat pump system
    Chen, Fei
    Mao, Jinfeng
    Chen, Shangyuan
    Li, Chaofeng
    Hou, Pumin
    Liao, Lu
    APPLIED THERMAL ENGINEERING, 2018, 130 : 698 - 709
  • [29] Simulation and experimental analysis of optimal buried depth of the vertical U-tube ground heat exchanger for a ground-coupled heat pump system
    Chen, Jinhua
    Xia, Lei
    Li, Baizhan
    Mmereki, Daniel
    RENEWABLE ENERGY, 2015, 73 : 46 - 54
  • [30] Comprehensive simulation based thermal performance comparison between single and double U-tube borehole heat exchanger and sensitivity analysis
    Kerme, Esa Dube
    Fung, Alan S.
    ENERGY AND BUILDINGS, 2021, 241