Assessment of left ventricular ejection fraction with quantitative gated SPECT: Accuracy and correlation with first-pass radionuclide angiography

被引:42
作者
Vallejo, E
Dione, DP
Sinusas, AJ
Wackers, FJT
机构
[1] Yale Univ, Sch Med, Cardiovasc Nucl Imaging Lab, Dept Diagnost Radiol, New Haven, CT 06520 USA
[2] Yale Univ, Sch Med, Cardiovasc Nucl Imaging Lab, Dept Internal Med, New Haven, CT 06520 USA
关键词
left ventricular ejection fraction; first-pass radionuclide angiography; quantitative gated single photon emission computed tomography;
D O I
10.1067/mnc.2000.107820
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Quantitative gated single photon emission computed tomography (SPECT [QGS]) software is widely used for the assessment of left ventricular ejection fraction (LVEF). Potentially confounding variables that may affect the accuracy of quantitative analysis of LVEF remain undefined. This study evaluated the accuracy of QGS as a means of determining LVEF in a wide range of LVEF values; evaluated the effect of extracardiac activity, count statistics, heart size, and perfusion defects on the accuracy of QGS LVEF; and compared QGS LVEF obtained at rest with that obtained after stress. Methods and Results. QGS-derived LVEF was compared with rest first-pass radionuclide angiography (FPRNA) LVEF in 400 electrocardiographic-gated SPECT studies. The overall correlation between QGS and FPRNA LVEF was only fair (r = 0.66, SEE = 11.85%). In 35 of the patient studies (9%) with high extracardiac activity, the automated software failed, and no correlation was obtained. In the remaining 365 patient studies (91%), left ventricular contours were successfully identified. In these studies, correlation was better (r = 0.74, SEE = 9.77%). Agreement was better for images with high counts (r = 0.81, SEE = 8.66%) than for images with low counts (r = 0.61, SEE = 11.17%). Patient studies with abnormal LVEF had better correlation (r = 0.77, SEE = 6.4%) than studies with normal LVEF (r = 0.46, SEE = 10.2%). Agreement between QGS LVEF and FPRNA LVEF was better in hearts with large end diastolic volumes (> 104 mL) than in hearts with small volumes. Overall, mean QGS LVEF was lower than mean FPRNA LVEF (54% +/- 14% vs 58% +/- 14%, P < .0001). There was no difference between mean rest and stress QGS LVEF in the same patients, even in patients with stress-induced ischemia. Conclusions. QGS is a valuable method for assessing resting LVEF. However, QGS LVEF is often lower than FPRNA LVEF. Accuracy is affected by high extracardiac activity, low count density, and small size of the left ventricle.
引用
收藏
页码:461 / 470
页数:10
相关论文
共 40 条
[1]   An investigation of the estimation of ejection fractions and cardiac volumes by a quantitative gated SPECT software package in simulated gated SPECT images [J].
Achtert, AD ;
King, MA ;
Dahlberg, ST ;
Pretorius, PH ;
LaCroix, KJ ;
Tsui, BMW .
JOURNAL OF NUCLEAR CARDIOLOGY, 1998, 5 (02) :144-152
[2]  
BERGER HJ, 1978, NUCLEAR CARDIOLOGY S, P29
[3]   MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION FROM GATED TC-99M SESTAMIBI MYOCARDIAL IMAGES [J].
BOONYAPRAPA, S ;
EKMAHACHAI, M ;
THANACHAIKUN, N ;
JAIPRASERT, W ;
SUKTHOMYA, V ;
PORAMATIKUL, N .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (06) :528-531
[4]   Segmentation of gated Tl-SPECT images and computation of ejection fraction: A different approach [J].
Brigger, P ;
Bacharach, SL ;
Srinivasan, G ;
Nour, KA ;
Carson, JA ;
Dilsizian, V ;
Aldroubi, A ;
Unser, M .
JOURNAL OF NUCLEAR CARDIOLOGY, 1999, 6 (03) :286-297
[5]  
CALLAHAN RJ, 1982, J NUCL MED, V23, P315
[6]   Validation of a new counts-based gated single photon emission computed tomography method for quantifying left ventricular systolic function: Comparison with equilibrium radionuclide angiography [J].
Calnon, DA ;
Kastner, RJ ;
Smith, WH ;
Segalla, D ;
Beller, GA ;
Watson, DD .
JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (06) :464-471
[7]   Overestimation of LVEF by gated MIBI myocardial perfusion SPECT in patients with small hearts [J].
Case, JA ;
Cullom, SJ ;
Bateman, TM ;
Barnhart, C ;
Saunders, MJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) :43A-43A
[8]   GATED TC-99M SESTAMIBI FOR SIMULTANEOUS ASSESSMENT OF STRESS MYOCARDIAL PERFUSION, POSTEXERCISE REGIONAL VENTRICULAR-FUNCTION AND MYOCARDIAL VIABILITY - CORRELATION WITH ECHOCARDIOGRAPHY AND REST TL-201 SCINTIGRAPHY [J].
CHUA, T ;
KIAT, H ;
GERMANO, G ;
MAURER, G ;
VANTRAIN, K ;
FRIEDMAN, J ;
BERMAN, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) :1107-1114
[9]  
DEPUEY EG, 1993, J NUCL MED, V34, P1871
[10]   FACTORS THAT AFFECT THE REPRODUCIBILITY OF MEASUREMENTS OF LEFT-VENTRICULAR FUNCTION FROM 1ST-PASS RADIONUCLIDE VENTRICULOGRAMS [J].
DYMOND, DS ;
ELLIOTT, A ;
STONE, D ;
HENDRIX, G ;
SPURRELL, R .
CIRCULATION, 1982, 65 (02) :311-322