Optimization and Validation of RP-LC/UV-VIS Detection Method for Simultaneous Determination of Fat-Soluble Anti-Oxidant Vitamins, all-trans-Retinol and α-Tocopherol in Human Serum: Effect of Experimental Parameters

被引:15
作者
Khan, Muhammad I. [1 ]
Khan, Abad [1 ]
Iqbal, Zafar [1 ]
Ahmad, Lateef [1 ]
Shah, Yasar [1 ]
机构
[1] Univ Peshawar, Dept Pharm, Peshawar 25120, Pakistan
关键词
Column liquid chromatography; UV-VIS detection; Optimization and validation; all-trans-Retinol and alpha-tocopherol; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIODE-ARRAY DETECTION; LOW-DENSITY LIPOPROTEINS; REVERSED-PHASE HPLC; BETA-CAROTENE; HUMAN PLASMA; SIMULTANEOUS QUANTIFICATION; COLUMN; PALMITATE; NUTRITION;
D O I
10.1365/s10337-010-1486-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A versatile isocratic reversed-phase liquid chromatographic/ultraviolet-visible detection method for simultaneous determination of all-trans-retinol and alpha-tocopherol in human serum was developed and validated after optimization of various chromatographic conditions and other experimental parameters. Analytes were separated on a Kromasil 100 RP(18) (150 x 4.6 mm, 5 mu m) analytical column protected by a Perkin Elmer RP(18) (30 x 4.6 mm, 10 mu m) guard cartridge. The mobile phase, methanol-water (96:04 v/v) was pumped at a flow rate of 2.2 mL min(-1) and the column eluents were monitored at the wavelength of 292 nm using retinyl acetate (1.0 mu g mL(-1)) as the internal standard for both analytes. Sample preparation was based on protein precipitation and stabilization with 2,6-bis(1,1-dimethylethyl)-4-methylphenol/ethanol and a two step extraction process using n-hexane followed by dichloromethane as extraction solvents. Sample size was kept 20 mu L and separation of analytes was achieved in less than 7 min. The present method demonstrated acceptable values for specificity/selectivity, linearity within the expected concentration range, recovery, precision, sensitivity, stability of solutions, robustness, and system suitability specifications and tests. The method was used for monitoring all-trans-retinol and alpha-tocopherol concentrations in human serum samples and could also be applied to other sample matrices such as brain slices and cosmetic products if attention is paid to the extraction procedure.
引用
收藏
页码:577 / 586
页数:10
相关论文
共 39 条
[1]  
Abahusain MA, 1998, BIOMED CHROMATOGR, V12, P89, DOI 10.1002/(SICI)1099-0801(199803/04)12:2<89::AID-BMC732>3.3.CO
[2]  
2-S
[3]   Chromatographic analysis of tocol-derived lipid antioxidants [J].
Abidi, SL .
JOURNAL OF CHROMATOGRAPHY A, 2000, 881 (1-2) :197-216
[4]   Rapid and sensitive high-performance liquid chromatographic method for simultaneous determination of retinol, α-tocopherol, 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human plasma with photodiode-array ultraviolet detection [J].
Alvarez, JC ;
De Mazancourt, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 755 (1-2) :129-135
[5]   HPLC analysis of fat-soluble vitamins on standard and narrow bore columns with UV, electrochemical and particle beam MS detection [J].
Andreoli, R ;
Careri, M ;
Manini, P ;
Mori, G ;
Musci, M .
CHROMATOGRAPHIA, 1997, 44 (11-12) :605-612
[6]   Simultaneous determination of retinol, β-carotene and α-tocopherol in adipose tissue by high-performance liquid chromatography [J].
Casal, S ;
Macedo, B ;
Oliveira, MBPP .
JOURNAL OF CHROMATOGRAPHY B, 2001, 763 (1-2) :1-8
[7]   Simultaneous analysis of Vitamins A and E in infant milk-based formulae by normal-phase high-performance liquid chromatography-diode array detection using a short narrow-bore column [J].
Chavez-Servin, Jorge L. ;
Castellote, Ana I. ;
Lopez-Sabater, M. Carmen .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1122 (1-2) :138-143
[8]   Comparison of a novel ultra-performance liquid chromatographic method for determination of retinol and α-tocopherol in human serum with conventional HPLC using monolithic and particulate columns [J].
Citova, I. ;
Havlikova, L. ;
Urbanek, L. ;
Solichova, D. ;
Novakova, L. ;
Solich, P. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (03) :675-681
[9]   Retinol, carotenoids, and tocopherols in the milk of lactating adolescents and relationships with plasma concentrations [J].
de Azeredo, Vilma B. ;
Trugo, Nadia M. F. .
NUTRITION, 2008, 24 (02) :133-139
[10]   Measurement uncertainty from validation and duplicate analysis results in HPLC analysis of multivitamin preparations and nutrients with different galenic forms [J].
De Beer, JO ;
Baten, P ;
Nsengyumva, C ;
Smeyers-Verbeke, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) :767-811